A digital reference object for the 3D Hoffman brain phantom for characterization of PET neuroimaging quality

被引:0
|
作者
Harrison, Robert L. [1 ]
Elston, Brian F. [1 ]
Byrd, Darrin W. [1 ]
Alessio, Adam M. [1 ]
Jacobs, Joshua
Rockne, Russell C.
Hawkins-Daarud, Andrea
Muzi, Mark [1 ]
Johnston, Sandra K. [1 ]
Jackson, Pamela R.
Swanson, Kristin R.
Kinahan, Paul E. [1 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
基金
美国国家卫生研究院;
关键词
PERFORMANCE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have developed a digital reference object that faithfully represents the structures in the Hoffman 3-D Brain Phantom (TM) from Data Spectrum Corporation. We have tested the fidelity of the DRO to the phantom by comparing the DRO to a CT scan, finding excellent agreement. We have also compared a PET simulation of the DRO to a PET scan of the phantom. The agreement between the simulated DRO and phantom PET scans was good.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Technical Note: A digital reference object representing Hoffman's 3D brain phantom for PET scanner simulations
    Harrison, Robert L.
    Elston, Brian F.
    Byrd, Darrin W.
    Alessio, Adam M.
    Swanson, Kristin R.
    Kinahan, Paul E.
    MEDICAL PHYSICS, 2020, 47 (03) : 1174 - 1180
  • [2] Multi scanner comparison using the Hoffman 3D Brain Phantom
    Yaqub, M.
    Lubberink, M.
    van Velden, F. H. P.
    Huisman, M. C.
    Lammertsma, A. A.
    Boellaard, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S294 - S294
  • [3] Optimization of PET activation studies based on the SNR measured in the 3-d Hoffman brain phantom
    Li, HT
    Votaw, JR
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (04) : 596 - 605
  • [4] Design and manufacture of a 3D printed phantom for PET quality control
    Robinson, J.
    Rushforth, D.
    Murray, I.
    Flux, G.
    Gear, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S14 - S14
  • [5] A phantom study evaluating the quantitative aspect of 3D PET imaging of the brain
    Sossi, V
    Oakes, TR
    Ruth, TJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (09): : 2615 - 2630
  • [6] Application of Unsupervised Spectral Clustering in 3D for PET Tumor Segmentation: A Digital Phantom Study
    Yang, F.
    Aristophanous, M.
    Yang, D.
    Low, D.
    Lu, W.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [7] 3D Breast Digital Phantom for XACT Imaging
    Tang, S.
    Chen, Y.
    Ahmad, S.
    Yang, K.
    Laaroussi, R.
    Chen, J.
    Samant, P.
    Xiang, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3389 - 3389
  • [8] The mouse reference brain in 3D
    Vogt, Nina
    NATURE METHODS, 2020, 17 (07) : 655 - 655
  • [9] The mouse reference brain in 3D
    Nina Vogt
    Nature Methods, 2020, 17 : 655 - 655
  • [10] Validation on an anthropomorphic phantom of FORE optimization in 3D PET
    De Bernardi, Elisabetta
    Mazzoli, Marco
    Zito, Felicia
    Baselli, Giuseppe
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2): : 247 - 250