Comparison of ultimate strength results from ACI and Eurocode 4 for steel tubular columns filled with SCC

被引:0
|
作者
Al-Goody, Asraa [1 ,2 ]
Guneyisi, Esra Mete [2 ]
Ipek, Suleyman [2 ]
机构
[1] Univ Technol Baghdad, Bldg & Construct Dept, Baghdad, Iraq
[2] Gaziantep Univ, Dept Civil Engn, Gaziantep, Turkey
关键词
CONCRETE; BEHAVIOR;
D O I
10.1051/matecconf/201816204002
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The Concrete Filled Steel Tubular (CFST) columns have several benefits in comparison to the ordinary steel or reinforced concrete ones. Therefore, they have become more commonly acknowledged in the structural applications. In this study, two design codes such as American Concrete Institute (ACI) and Eurocode 4 (EC4) were used for predicting the ultimate axial strength of CFST columns filled with self-compacting concrete (SCC). To evaluate the results, circular steel tube with different diameter to thickness (D/t) ratio of 30, 60, and 90 and steel yielding strength of 185, 275, and 450 MPa were considered as prediction parameters. The wall thickness and length to diameter (L/D) ratio of the steel tubes were kept constant. As an infill material for the steel tubes, 16 different SCC mixtures reported in the literature were studied and their compressive strength results were used to get the code predicted ultimate axial strength of the composite columns. The analysis of the results based on ACI and EC4 were performed and discussed comparatively.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] BEHAVIOR AND ULTIMATE STRENGTH OF SHORT CONCRETE-FILLED STEEL TUBULAR COLUMNS.
    Cai Shaohuai
    Jiao Zhanshuan
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 1984, 5 (06): : 13 - 29
  • [2] BEHAVIOUR AND ULTIMATE STRENGTH OF LONG CONCRETE-FILLED STEEL TUBULAR COLUMNS.
    Cai Shaohuai
    Gu Wanli
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 1985, 6 (01): : 32 - 40
  • [3] ULTIMATE LOADING CAPACITY OF RC COLUMNS UNDER FIRE: COMPARISON OF ACI AND EUROCODE MODELS
    Barros, H.
    Ferreira, C.
    Silva, V. D.
    PROCEEDINGS OF THE 1ST PAN-AMERICAN CONGRESS ON COMPUTATIONAL MECHANICS AND XI ARGENTINE CONGRESS ON COMPUTATIONAL MECHANICS, 2015, : 525 - 530
  • [4] Strength of Concrete Filled Steel Tubular Columns
    Muhammad Naseem Baig
    樊健生
    聂建国
    Tsinghua Science and Technology, 2006, (06) : 657 - 666
  • [5] Strength of concrete filled steel tubular columns
    Department of Civil Engineering, Tsinghua University, Beijing 100084, China
    Tsinghua Sci. Tech., 2006, 6 (657-666):
  • [6] Comparison between ACI and AISC for concrete-filled tubular columns
    Zhang, Weizi
    Shahrooz, Bahrain M.
    Journal of structural engineering New York, N.Y., 1999, 125 (11): : 1213 - 1223
  • [7] Comparison between ACI and AISC for concrete-filled tubular columns
    Zhang, WZ
    Shahrooz, BM
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1999, 125 (11): : 1213 - 1223
  • [8] The Ultimate Strength of the Concrete-Filled Tubular (CFT) Section Columns
    Kwon, Young Bong
    Jeong, In Kyu
    Kwon, In Kyu
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING, PTS. 1-5, 2012, 204-208 : 899 - 902
  • [9] BEHAVIOUR AND ULTIMATE STRENGTH OF CONCRETE-FILLED STEEL TUBULAR COLUMNS UNDER ECCENTRIC LOADING.
    Cai Shaohuai
    Di Xiaotan
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 1985, 6 (04): : 32 - 42
  • [10] Comparison of a Three-Dimensional Numerical Model for Fire Resistance of Axially Loaded Concrete Filled Steel Tubular Columns with Eurocode 4
    Espinos, Ana
    Ibanez, Carmen
    Romero, Manuel L.
    Hospitaler, Antonio
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2011, 2 (02) : 67 - 79