MRI-Derived Myocardial Strain Measures in Normal Subjects

被引:117
|
作者
Vo, Ha Q. [1 ]
Marwick, Thomas H. [1 ,2 ]
Negishi, Kazuaki [1 ]
机构
[1] Univ Tasmania, Menzies Inst Med Res, 17 Liverpool St,Private Bag 23, Hobart, Tas 7000, Australia
[2] Baker IDI Heart & Diabet Inst, Melbourne, Vic, Australia
关键词
DENSE; feature tracking; healthy; magnetic resonance; meta-analysis; normal range; SENC; strain; tagging; RESONANCE FEATURE-TRACKING; TISSUE TRACKING; MECHANICS; ECHOCARDIOGRAPHY; QUANTIFICATION; CARDIOMYOPATHY;
D O I
10.1016/j.jcmg.2016.12.025
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The aim of this study was to perform a systematic review and meta-analysis to estimate the normal ranges of magnetic resonance imaging (MRI)-based feature tracking (FT) and to identify sources of variations. Similar analyses were also performed for strain encoding, displacement encoding with stimulated echoes, and myocardial tagging. BACKGROUND MRI-FT is a novel technique for quantification of myocardial deformation using MRI cine images. However, the reported 95% confidence intervals (CIs) from the 2 largest studies have no overlaps. METHODS Four databases (EMBASE, SCOPUS, PUBMED, and Web of Science) were systematically searched for MRI strains of the left (LV) and right (RV) ventricles. The key terms for MRI-FT were "tissue tracking," "feature tracking," "cardiac magnetic resonance," "cardiac MRI," "CMR," and "strain." A random effects model was used to pool LV global longitudinal strain (GLS), global circumferential strain (GCS), global radial strain (GRS), and RVGLS. Meta-regressions were used to identify the sources of variations. RESULTS 659 healthy subjects were included from 18 papers for MRI-FT. Pooled mean of LVGLS was -20.1% (95% CI: -20.9% to -19.3%), LVGCS -23% (95% CI: -24.3% to -21.7%), LVGRS 34.1% (95% CI: 28.5% to 39.7%), and RVGLS -21.8% (95% CI: -23.3% to -20.2%). Although there were no publication biases except for LVGCS, significant heterogeneities were found. Meta-regression showed that variation of LVGCS was associated with field strength (beta = 3.2; p = 0.041). Variations of LVGLS, LVGRS, and RVGLS were not associated with any of age, sex, software, field strength, sequence, LV ejection fraction, or LV size. LVGCS seems the most robust in MRI-FT. Among the MRI-derived strain techniques, the normal ranges were mostly concordant in LVGLS and LVGCS but varied substantially in LVGRS and RVGLS. CONCLUSIONS The pooled means of 4 MRI-derived myocardial strain methods in normal subjects are demonstrated. Differences in field strength were attributed to variations of LVGCS. (c) 2018 by the American College of Cardiology Foundation.
引用
收藏
页码:196 / 205
页数:10
相关论文
共 50 条
  • [1] Myocardial strain rate in normal subjects
    Monte, Ines
    Licciardi, Salvatore
    Modica, Giovanni
    GIORNALE ITALIANO DI CARDIOLOGIA, 2005, 6 (09) : 604 - 611
  • [2] Comparison of MRI-derived pulmonary edema measures with LVEDP and serum BNP
    Kelvin Chow
    Mustafa Toma
    Ben Esch
    Jessica Scott
    Mark Haykowsky
    Richard Thompson
    Ian Paterson
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [3] How reproducible are PET- and MRI-derived measures of brain connectivity?
    Lizarraga, A.
    Ripp, I.
    Sala, A.
    Koch, K.
    Yakushev, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S253 - S253
  • [4] Data on correlation between CT-derived and MRI-derived myocardial extracellular volume
    Kurita, Yoshie
    Kitagawa, Kakuya
    Kurobe, Yusuke
    Nakamori, Shiro
    Nakajima, Hiroshi
    Dohi, Kaoru
    Ito, Masaaki
    Sakuma, Hajime
    DATA IN BRIEF, 2016, 7 : 1045 - 1047
  • [5] Sedentary Time and MRI-Derived Measures of Adiposity in Active Versus Inactive Individuals
    Henson, Joseph
    Edwardson, Charlotte L.
    Morgan, Bruno
    Horsfield, Mark A.
    Khunti, Kamlesh
    Davies, Melanie J.
    Yates, Thomas
    OBESITY, 2018, 26 (01) : 29 - 36
  • [6] REPRODUCIBILITY OF MRI-DERIVED MEASUREMENTS OF RIGHT-VENTRICULAR VOLUMES AND MYOCARDIAL MASS
    PATTYNAMA, PMT
    LAMB, HJ
    VANDERVELDE, EA
    VANDERGEEST, RJ
    VANDERWALL, EE
    DEROOS, A
    MAGNETIC RESONANCE IMAGING, 1995, 13 (01) : 53 - 63
  • [7] Association Between CT-Derived Emphysema and MRI-Derived Fractional Ventilation in Advanced COPD Subjects
    Baron, R.
    Hamedani, H.
    Amzajerdian, F.
    Kadlecek, S.
    Duncan, I.
    Xin, Y.
    Siddiqui, S.
    Cereda, M.
    Rizi, R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199
  • [8] Normative data of MRI-derived thalamic volumes from a large dataset of healthy subjects
    Gentile, G.
    Luchetti, L.
    Giorgio, A.
    Battaglini, M.
    De Stefano, N.
    MULTIPLE SCLEROSIS JOURNAL, 2017, 23 : 244 - 245
  • [9] Normative data of MRI-derived hippocampal volume from a large dataset of healthy subjects
    Luchetti, L.
    Gentile, G.
    Giorgio, A.
    Battaglini, M.
    De Stefano, N.
    MULTIPLE SCLEROSIS JOURNAL, 2017, 23 : 796 - 796
  • [10] FreeSurfer reproducibility of MRI-derived measurements of longitudinal volume changes in MS subjects: impact of change in MRI scanners
    Belaroussi, B.
    Durand-Dubief, F.
    Bracoud, L.
    Vukusic, S.
    Pachai, C.
    Confavreux, C.
    MULTIPLE SCLEROSIS JOURNAL, 2011, 17 : S375 - S375