Spectromicroscopy of boron for the optimization of boron neutron capture therapy (BNCT) for cancer

被引:5
|
作者
Gilbert, B [1 ]
Redondo, J
Baudat, PA
Lorusso, GF
Andres, R
Van Meir, EG
Brunet, JF
Hamou, MF
Suda, T
Mercanti, D
Ciotti, MT
Droubay, TC
Tonner, BP
Perfetti, P
Margaritondo, M
De Stasio, G
机构
[1] Ecole Polytech Fed Lausanne, Inst Phys Appl, PH Ecublens, CH-1015 Lausanne, Switzerland
[2] Univ Wisconsin, Ctr Xray Lithog, Stoughton, WI USA
[3] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[4] Emory Univ, Winship Canc Ctr, Mol Genet Lab, Atlanta, GA 30322 USA
[5] CHU Vaudois, Neurosurg Serv, Lab Tumor Biol & Genet, CH-1011 Lausanne, Switzerland
[6] CNR, Inst Neurobiol, I-00137 Rome, Italy
[7] Univ Wisconsin, Dept Phys, Milwaukee, WI 53211 USA
[8] CNR, Ist Struttura Mat, I-00133 Rome, Italy
[9] Sincrotrone Trieste, I-34012 Trieste, Italy
关键词
D O I
10.1088/0022-3727/31/19/038
中图分类号
O59 [应用物理学];
学科分类号
摘要
We used synchrotron spectromicroscopy to study the microscopic distribution of baron in rat brain tumour and healthy tissue in the field of baron neutron capture therapy (BNCT). The success of this experimental cancer therapy depends on the preferential uptake of B-10 in tumour cells after injection of a baron compound (in our case B12H11SH, or BSH). With the Mephisto (microscope a emission de photoelectrons par illumination synchrotronique de type onduleur) spectromicroscope, high-magnification imaging and chemical analysis was performed on brain tissue sections from a rat carrying an implanted brain tumour and the results were compared with inductively coupled plasma-atomic emission spectroscopy (ICP-AES) detection of boron in bulk tissue. Boron was found to have been taken up more favourably by regions of tumour rather than healthy tissue, but the resulting boron distribution in the tumour was inhomogeneous. The results demonstrate that Mephisto can perform microchemical analysis of tissue sections, detect and localize the presence of boron with submicron spatial resolution. The application of this technique to boron in brain tissue can therefore be used to evaluate the current efforts to optimize BNC therapy.
引用
收藏
页码:2642 / 2647
页数:6
相关论文
共 50 条
  • [1] RENAISSANCE OF THE BORON NEUTRON CAPTURE THERAPY, BNCT
    Gryzinski, M. A.
    Maciak, M.
    Wielgosz, M.
    RAD 2015: THE THIRD INTERNATIONAL CONFERENCE ON RADIATION AND APPLICATIONS IN VARIOUS FIELDS OF RESEARCH, 2015, : 79 - 81
  • [2] Methods for boron analysis in boron neutron capture therapy (BNCT). A review
    Thomas U. Probst
    Fresenius' Journal of Analytical Chemistry, 1999, 364 : 391 - 403
  • [3] Methods for boron analysis in boron neutron capture therapy (BNCT). A review
    Probst, TU
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (05): : 391 - 403
  • [4] The Development of Boron Analysis and Imaging in Boron Neutron Capture Therapy (BNCT)
    Dai, Qi
    Yang, QiYao
    Bao, Xiaoyan
    Chen, Jiejian
    Han, Min
    Wei, Qichun
    MOLECULAR PHARMACEUTICS, 2022, 19 (02) : 363 - 377
  • [5] Boron analysis and boron imaging in biological materials for Boron Neutron Capture Therapy (BNCT)
    Wittig, Andrea
    Michel, Jean
    Moss, Raymond L.
    Stecher-Rasmussen, Finn
    Arlinghaus, Heinrich F.
    Bendel, Peter
    Mauri, Pier Luigi
    Altieri, Saverio
    Hilger, Ralf
    Salvadori, Piero A.
    Menichetti, Luca
    Zamenhof, Robert
    Sauerwein, Wolfgang A. G.
    CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2008, 68 (01) : 66 - 90
  • [6] Efficacy of boron neutron capture therapy (BNCT) for patients with oral cancer
    Miyaguchi, Jun
    Shiga, Kiyoto
    Katagiri, Katsunori
    Saito, Daisuke
    Tsuchida, Kodai
    Kusaka, Takahiro
    Ohashi, Yu
    Kusaka, Iori
    Takai, Yoshihiro
    ORAL ONCOLOGY, 2025, 163
  • [7] Boron neutron capture therapy (BNCT):: Implications of neutron beam and boron compound characteristics
    Wheeler, FJ
    Nigg, DW
    Capala, J
    Watkins, PRD
    Vroegindeweij, C
    Auterinen, I
    Seppälä, T
    Bleuel, D
    MEDICAL PHYSICS, 1999, 26 (07) : 1237 - 1244
  • [8] Potential of boron neutron capture therapy (BNCT) for myxofibrosarcoma
    Fujimoto, Takuya
    Andoh, Tooru
    Sudo, Tamotsu
    Fujita, Ikuo
    Sakurai, Yoshinori
    Takata, Takushi
    Tanaka, Hiroki
    Kawamoto, Teruya
    Yahiro, Shunsuke
    Nakamura, Shotaro
    Hara, Hitomi
    Fukase, Naomasa
    Akisue, Toshihiro
    Ichikawa, Hideki
    Kuroda, Ryosuke
    Suzuki, Minoru
    APPLIED RADIATION AND ISOTOPES, 2025, 217
  • [9] The Finnish boron neutron capture therapy (BNCT) project
    Auterinen, I
    15TH EUROPEAN TRIGA CONFERENCE, 1999, 197 : 121 - 131
  • [10] Boron neutron capture therapy (BNCT) - radiotherapy of the future?
    Sauerwein, W.
    Matsumura, A.
    Moss, R.
    Busse, P.
    Wittig, A.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 : 43 - 43