Dynamic geometrical shape measurement and structural analysis of inflatable membrane structures using a low-cost three-camera system

被引:17
|
作者
Zhao, Bing [1 ,2 ]
Hu, Jianhui [1 ]
Chen, Wujun [1 ]
Chen, Jianwen [3 ]
Jing, Zhongliang [2 ]
机构
[1] Shanghai Jiao Tong Univ, Space Struct Res Ctr, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Aeronaut & Astronaut, Shanghai 200240, Peoples R China
[3] Nanjing Univ Sci & Technol, Dept Civil & Engn, Nanjing 210094, Jiangsu, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Inflatable membrane structures; Dynamic geometrical shape; In-situ measurement; Stress distribution; Inflated forming experiment; ETFE inflated cushion model; MECHANICAL-PROPERTIES; ETFE FOILS; CUSHION STRUCTURES; PERFORMANCE; BEHAVIOR;
D O I
10.1016/j.autcon.2018.09.025
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Inflatable membrane structures have gained considerable popularity in recent years owing to the advantages of light weight, beautiful surface and durability. This paper concerns the dynamic geometrical shape in-situ measurement and structural analysis of inflatable membrane structures using a low-cost three-camera system. The measurement system was developed based on three-dimensional (3D) digital photogrammetry. In order to acquire the high-quality measurement results, accuracy influence factors of the system were evaluated. Based on these considerations, dynamic geometrical shapes of inflatable membrane structures can be real-timely measured through the data processing which is used to determine the 3D coordinates of the target points pasted on membrane surfaces from the two-dimensional (2D) photographs captured by three cameras. Following the in-situ measurement of geometrical shape, the stress distributions of inflatable membrane structures can be determined based on the force equilibriums of membrane surfaces between the in-plane forces and out-of-plane loads. For verifying the proposed method, a selected ethylene-tetrafluoroethylene (E I PE) inflated cushion structure model was manufactured and employed for the experimental study of pre-inflated forming and normal working. By carefully analyzing and comparing the experimental results, it is observed that the measurement accuracy was better than 1/11000. More importantly, the geometrical shape of ETFE cushion still deformed with + 5.81% difference during the normal working process of 6 months, resulting in that the maximum stress decreased with - 3.49% difference. In general, this paper could provide an efficient and accurate method to measure the dynamic geometrical shapes of inflatable membrane structures, which is the basic information for the further structural analysis.
引用
收藏
页码:442 / 456
页数:15
相关论文
共 50 条
  • [1] Calibration of a low-cost measurement system by using a consumer digital stereo camera
    Matsuoka, Ryuji
    Takahashi, Genki
    Asonuma, Kazuyoshi
    VIDEOMETRICS, RANGE IMAGING, AND APPLICATIONS XI, 2011, 8085
  • [2] Computational method for in-situ finite element modeling of inflatable membrane structures based on geometrical shape measurement using photogrammetry
    Zhao, Bing
    Hu, Jianhui
    Chen, Wujun
    Chen, Jianwen
    Qiu, Zhenyu
    Jing, Zhongliang
    COMPUTERS & STRUCTURES, 2019, 224
  • [3] Evaluation of a Low-cost Inertial Dynamic Measurement System
    Gao, Jian
    Webb, Phil
    Gindy, Nabil
    2008 IEEE CONFERENCE ON ROBOTICS, AUTOMATION, AND MECHATRONICS, VOLS 1 AND 2, 2008, : 913 - +
  • [4] Design and Validation of a Low-Cost Structural Health Monitoring System for Dynamic Characterization of Structures
    Caballero-Russi, David
    Ortiz, Albert R.
    Guzman, Andres
    Canchila, Carlos
    APPLIED SCIENCES-BASEL, 2022, 12 (06):
  • [5] A THREE-CAMERA DIGITAL IMAGE CORRELATION SYSTEM FOR FULL-FIELD 3D SHAPE AND MOTION MEASUREMENT
    Luan, Likang
    Crosbie, Liam
    MATERIALS EVALUATION, 2022, 80 (11) : 34 - 41
  • [6] A Low-Cost Robotic Camera System for Accurate Collection of Structural Response
    Kromanis, Rolands
    Forbes, Christopher
    INVENTIONS, 2019, 4 (03)
  • [7] Automatic Tilting Correction System for Inhibition Zones Dimension Measurement using Low-Cost Camera
    Prakoso, Giri Yudho
    Saputro, Adhi Harmoko
    Handayani, Windri
    Santoso, Iman
    Imawan, Cuk
    2016 INTERNATIONAL SEMINAR ON SENSORS, INSTRUMENTATION, MEASUREMENT AND METROLOGY (ISSIMM), 2016, : 75 - 78
  • [8] A Low-cost Fire Detection System using a Thermal Camera
    Nam, Yun-Cheol
    Nam, Yunyoung
    KSII TRANSACTIONS ON INTERNET AND INFORMATION SYSTEMS, 2018, 12 (03): : 1301 - 1314
  • [9] Development of a Low-Cost System for the Accurate Measurement of Structural Vibrations
    Komarizadehasl, Seyedmilad
    Mobaraki, Behnam
    Ma, Haiying
    Lozano-Galant, Jose-Antonio
    Turmo, Jose
    SENSORS, 2021, 21 (18)
  • [10] Development of a low-cost system for the measurement of dynamic equilibrium in humans
    Silva M.G.
    Martins M.S.
    Tupinambá W.L.M.
    Tomazini J.E.
    Research on Biomedical Engineering, 2024, 40 (3-4) : 593 - 608