Comparison of plethysmographic and helium dilution lung volumes in patients with a giant emphysematous bulla as selection criteria for endobronchial valve implant

被引:0
|
作者
Fiorelli, Alfonso [1 ]
Scaramuzzi, Roberto [1 ]
Pierdiluca, Matteo [1 ]
Frongillo, Elisabetta [1 ]
Messina, Gaetana [1 ]
Serra, Nicola [2 ]
De Felice, Alberto [3 ]
Santini, Mario [1 ]
Okumura, M.
Eid, H.
Waller, D.
机构
[1] Univ Campania Luigi Vanvitelli, Thorac Surg Unit, Naples, Italy
[2] Univ Campania Luigi Vanvitelli, Dept Radiol, Naples, Italy
[3] Clin Maugeri, Dept Pulm Rehabil, Telese, Caserta, Italy
关键词
Endobronchial valves; Emphysema; Giant bulla; Plethysmography; Helium dilution technique; ONE-WAY VALVES; COMPUTED-TOMOGRAPHY; BRONCHOSCOPIC PLACEMENT; BULLECTOMY; REDUCTION; DISEASE;
D O I
10.1093/ejcts/ezx108
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: To assess whether the difference in lung volume measured with plethysmography and with the helium dilution technique could differentiate an open from a closed bulla in patients with a giant emphysematous bulla and could be used as a selection criterion for the positioning of an endobronchial valve. METHODS: We reviewed the data of 27 consecutive patients with a giant emphysematous bulla undergoing treatment with an endobronchial valve. In addition to standard functional and radiological examinations, total lung capacity and residual volume were measured with the plethysmographic and helium dilution technique. We divided the patients into 2 groups, the collapse or the no-collapse group, depending on whether the bulla collapsed or not after the valves were put in position. We statistically evaluated the intergroup differences in lung volume and outcome. RESULTS: In the no-collapse group (n = 6), the baseline plethysmographic values were significantly higher than the helium dilution volumes, including total lung capacity (188 +/- 14 vs 145 +/- 13, P = 0.0007) and residual volume (156 +/- 156 vs 115 +/- 15, P = 0.001). In the collapse group, there was no significant difference in lung volumes measured with the 2 methods. A difference in total lung capacity of <= 13% and in residual volume of <= 25% measured with the 2 methods predicted the collapse of the bulla with a success rate of 83% and 84%, respectively. Only the collapse group showed significant improvement in functional data. CONCLUSIONS: Similar values in lung volumes measured with the 2 methods support the hypothesis that the bulla communicates with the airway (open bulla) and thus is likely to collapse when the endobronchial valve is implanted. Further studies are needed to validate our model.
引用
收藏
页码:534 / 542
页数:9
相关论文
共 3 条
  • [1] Comparison of helium dilution and plethysmographic lung volumes in pregnant women
    GarciaRio, F
    PinoGarcia, JM
    Serrano, S
    Racionero, MA
    TerrerosCaro, JG
    AlvarezSala, R
    Villasante, C
    Villamor, J
    EUROPEAN RESPIRATORY JOURNAL, 1997, 10 (10) : 2371 - 2375
  • [2] Comparison of Plethysmographic and Helium Dilution Lung Volumes Which Is Best for COPD?
    O'Donnell, Carl R.
    Bankier, Alexander A.
    Stiebellehner, Leopold
    Reilly, John J.
    Brown, Robert
    Loring, Stephen. H.
    CHEST, 2010, 137 (05) : 1108 - 1115
  • [3] A pilot comparison of helium dilution and plethysmographic lung volumes to assess the impact of a long-acting bronchodilator on lung hyperinflation in COPD
    Cazzola, Mario
    Rogliani, Paola
    Curradi, Giacomo
    Segreti, Andrea
    Ciaprini, Chiara
    Pezzuto, Gabriella
    Saltini, Cesare
    PULMONARY PHARMACOLOGY & THERAPEUTICS, 2009, 22 (06) : 522 - 525