Clinical outcomes and cost-utility after sirolimus-eluting versus bare metal stent implantation

被引:4
|
作者
Zhao Fu-hai [1 ]
Lue Shu-zheng [1 ]
Li Hui [2 ]
Ning Shang-qiu [1 ]
Yuan Fei [1 ]
Song Xian-tao [1 ]
Jin Ze-ning [1 ]
Zhou Yuan [1 ]
Chen Xin [1 ]
Liu Hong [1 ]
Tian Rui [1 ]
Meng Kang [1 ]
Li Hong [1 ]
Han Feng [2 ]
机构
[1] Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiol, Beijing 100029, Peoples R China
[2] China Res Assoc Med Insurance Fund, Beijing 100029, Peoples R China
关键词
sirolimus-eluting stent; bare metal stent; clinical outcomes; cost-utility; health-related quality of life; QUALITY-OF-LIFE; BYPASS GRAFT-SURGERY; TRIAL; THROMBOSIS; ANGIOPLASTY; RESTENOSIS; LESIONS; EVENTS; ANGINA; RISK;
D O I
10.3760/cma.j.issn.0366-6999.2010.20.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Randomized studies have shown beneficial effects of drug-eluting stent (DES) in reducing the risk of repeated revascularization. Other studies have shown higher proportion of death, myocardial infarction (MI) and increased cost concerning DES. However the long term safety and effectiveness of DES have been questioned recently. Methods To compare long term clinical outcomes, health-related quality of life (HRQOL) and cost-utility after sirolimus-eluting stent (SES) and bare metal stent (BMS) implantation in angina patients in China, 1241 patients undergoing percutaneous coronary revascularization (PCI) with either SES (n=632) or BMS (n=609) were enrolled continuously in this prospective, nonrandomized, multi-center registry study. Results Totally 1570 stents were implanted for 1334 lesions. Follow-up was completed in 1205 (97.1%) patients at 12 months. Rates of MI, all causes of death were similar between the two groups. Significant differences were found at rate of cardiovascular re-hospitalization (136 (22.4%) in BMS group vs. 68 (10.8%) in SES group, P=0.001) and recurrent angina (149 (24.5%) vs. 71 (11.3%), P=0.001). Dramatic difference was observed when compared the baseline and 9-month HRQOL scores intra-group (P < 0.001). However no significant difference was found inter-group either in baseline or follow-up HRQOL. Compared with SES, the total cost in BMS was significantly lower on discharge (62 546.0 vs. 78 245.0 Yuan, P=0.001). And follow-up expenditure was remarkably higher in the BMS group than that in the SES group (13 412.0 vs. 8 812.0 Yuan, P=0.0001). Conclusions There were no significant differences on death, in-stent thrombosis, MI irrespective of stent type. SES was superior to BMS on improvement of life quality. SES was with higher cost-utility compared to BMS. Chin Med J 2010;123(20):2797-2802
引用
收藏
页码:2797 / 2802
页数:6
相关论文
共 50 条
  • [2] Comparison of incidence and clinical features of coronary stent fracture after sirolimus-eluting stent implantation versus bare metal stent implantation
    Nishibori, Yoshiharu
    Fujita, Hiroshi
    Matsuo, Akiko
    Matsuo, Kiyonari
    Shiono, Yasutsugu
    Nakanishi, Naohiko
    Yamaguchi, Shin-ichiro
    Inoue, Keiji
    Tanaka, Tetsuya
    Kitamura, Makoto
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : B38 - B38
  • [3] Repeated Sirolimus-Eluting Stent Implantation to Treat Sirolimus-Eluting Stent and Bare-Metal Stent Restenosis
    Nishihira, Kensaku
    Shibata, Yoshisato
    Ishikawa, Tetsunori
    Nomura, Katsumasa
    Nakama, Tatsuya
    Mine, Daigo
    Inoue, Yohei
    Ashikaga, Keiichi
    Kuriyama, Nehiro
    Matsuyama, Akihiko
    Imamura, Takuroh
    Asada, Yujiro
    Kitamura, Kazuo
    CIRCULATION JOURNAL, 2010, 74 (11) : 2329 - 2333
  • [4] Late Progression After Sirolimus-Eluting Stent Implantation: Comparison with Bare Metal Stent Implantation
    Shiode, Nobuo
    Shirota, Kinya
    Fukuda, Yukihiro
    Katou, Yasuko
    Tsunoda, Fumiyo
    Fujiwara, Mai
    Mimura, Asao
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A12 - A12
  • [5] Five-year clinical outcomes of dialysis patients after sirolimus-eluting stent implantation compared with bare metal stent
    Yachi, S.
    Aoki, J.
    Tanabe, K.
    Tanimoto, S.
    Kishi, S.
    Taniwaki, S.
    Nakajima, Y.
    Nakajima, H.
    Hara, K.
    EUROPEAN HEART JOURNAL, 2011, 32 : 237 - 237
  • [6] Coronary collateral growth after sirolimus-eluting stent implantation compared with bare metal stent implantation
    kaneda, Hideaki
    Shiono, Takaaki
    Miyashita, Yusuke
    Takahashi, Saeko
    Taketani, Yoshio
    Domae, Hiroshi
    Matsumi, Junya
    Misuno, Shingo
    Minami, Yoshiyasu
    Sugitatsu, Kazuya
    Saito, Shigero
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (8A): : 81L - 82L
  • [7] Sirolimus-eluting versus bare-metal stent implantation in patients with ostial lesions
    Jorgensen, Erik
    Kelbaek, Henning
    Klovgaard, Lene
    Thuesen, Leif
    Krusell, Lars R.
    Botker, Hans E.
    Saunamaki, Kari
    Lassen, Jens F.
    Helqvist, Steffen
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 145 (01) : 162 - 163
  • [8] Simultaneous subacute stent thrombosis after implantation of sirolimus-eluting stent and bare-metal stent
    Kang, Woong Chol
    Moon, Chan Il
    Ahn, Tae Hoon
    Shin, Eak Kyun
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 127 (02) : E89 - E92
  • [9] Comparison of incidence and clinical features of coronary stent fracture after sirolimus-eluting stent implantation vs bare metal stent implantation
    Nishibori, Y.
    Fujita, H.
    Matsuo, K.
    Nakanishi, N.
    Shiono, Y.
    Yamaguchi, S.
    Matsuo, A.
    Inoue, K.
    Tanaka, T.
    Kitamura, M.
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 101 (8B): : 50C - 50C
  • [10] Angiographic evaluation of collateral growth after sirolimus-eluting stent implantation compared with bare metal stent
    Shiono, T.
    Saito, S.
    Kaneda, H.
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 101 (8B): : 52C - 53C