Enhancing acoustic signal quality by rapidly switching between pulse-echo and through-transmission using diplexers

被引:0
|
作者
Valencia, Juan D. [1 ]
Diaz, Aaron A. [1 ]
Tucker, Brian J. [1 ]
机构
[1] Pacific NW Natl Lab, Richland, WA 99352 USA
关键词
ultrasonic; diplexer; signal isolation; noise reduction; pulse-echo; through-transmission; noninvasive; nondestructive; classification;
D O I
10.1117/12.776427
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The increase of terrorism and its global impact has made the screening of the contents of liquid-filled containers a necessity. The ability to evaluate the contents of a container rapidly and accurately is a critical tool in maintaining global safety and security. Due to the immense quantities and large variety of containers shipped worldwide, there is a need for a technology that enables rapid and effective ways of conducting non-intrusive container inspections. Such inspections can be performed utilizing "through-transmission" or "pulse-echo" acoustic techniques, in combination with multiple frequency excitation pulses or waveforms. The challenge is combining and switching between the different acoustic techniques without distorting the excitation pulse or waveform, degrading or adding noise to the receive signal; while maintaining a portable, low-power, low-cost, and easy to use system. The Pacific Northwest National Laboratory (PNNL) has developed a methodology and prototype device focused on this challenge. The prototype relies on an advanced diplexer circuit capable of rapidly switching between both "through-transmission" and "pulse-echo" detection modes. This type of detection requires the prototype to isolate the pulsing circuitry from the receiving circuitry to prevent damage and reduce noise. The results of this work demonstrate that an advanced diplexer circuit can be effective; however, some bandwidth issues exist. This paper focuses on laboratory measurements and test results acquired with the PNNL prototype device as applied to several types of liquid-filled containers. Results of work conducted in the laboratory will be presented and future measurement platform enhancements will be discussed.
引用
收藏
页数:8
相关论文
共 6 条
  • [1] Enhancing the ultrasonic waveguide sensor's fluid level sensitivity using through-transmission and pulse-echo techniques simultaneously
    Kumar, Abhishek
    Periyannan, Suresh
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (06):
  • [2] Simultaneous use of pulse-echo and through-transmission methods in determining a combined reflection coefficient
    Dourado, T. C.
    Alvarenga, A. V.
    Peters, F. C.
    Mansur, W. J.
    Costa-Felix, R. P. B.
    APPLIED ACOUSTICS, 2022, 192
  • [3] Numerical Study on Surface Roughness Measurement Based on Nonlinear Ultrasonics in Through-Transmission and Pulse-Echo Modes
    Yuan, Maodan
    Dai, Anbang
    Liao, Lin
    Chen, Yan
    Ji, Xuanrong
    MATERIALS, 2021, 14 (17)
  • [4] Comparisons of second- and third-order ultrasonic nonlinearity parameters measured using through-transmission and pulse-echo methods
    Bang, Sung-Jun
    Song, Dong-Gi
    Jhang, Kyung-Young
    NDT & E INTERNATIONAL, 2023, 133
  • [5] Low frequency ultrasonic absorption in aqueous solutions from variable path through-transmission and pulse-echo measurements
    Lirette, Robert
    Musial, Malgorzata
    Widegren, Jason A.
    Stelson, Angela C.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2023, 153 (03):
  • [6] Acoustic Refractive Index Measurement using Tone Burst Signal as an Alternative to Broadband Pulse by Through-Transmission Method
    Yusof, Nurhalawa Md
    Kim, Sung Mok
    Kim, Yong Tae
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2021, 41 (03) : 155 - 163