Hydroxyapatite-Coated Pins Versus Titanium Alloy Pins in External Fixation at the Wrist: A Controlled Cohort Study

被引:12
|
作者
Pieske, Oliver [1 ]
Pichlmaier, Leopold [1 ]
Kaltenhauser, Felicitas [1 ]
Schramm, Nicolai [2 ]
Rubenbauer, Bianka [1 ]
Greiner, Axel [1 ]
Piltz, Stefan [1 ]
机构
[1] Univ Hosp Munich, Dept Trauma Surg, D-81377 Munich, Germany
[2] Univ Hosp Munich, Dept Clin Radiol, D-81377 Munich, Germany
关键词
External fixation; Pin-track; Complication; Hydroxyapatite; Titanium-alloy; TRACK INFECTION; DISTAL RADIUS; SHORT STATURE; FRACTURES; STRENGTH; SCREWS; COMPLICATIONS; INTERFACE; MODEL; BONE;
D O I
10.1097/TA.0b013e3181e97761
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The purpose of this study was to analyze whether the prevalence of pin-related complications can be reduced by the use of hydroxyapatite (HA)-coated pins in external fixators applied for unstable wrist fractures. Methods: Forty patients (160 pins) were randomized for standard uniplanar fixator treatment with the use of identically designed pins either composed of titanium-alloy (Ti6Al4V) (n = 20) or coated by HA (n = 20). Each pin site was clinically evaluated with regard to erythema, drainage, pain value, and radiologically assessed concerning loosening at T1 (mean, 9 days), T2 (mean, 43 days), and T3 (mean, 56 days). In case of pin-track complication, the patient was followed continuously. The need for antibiotics or additional surgery was documented. Bone mineral density was analyzed by Dual Energy X-ray Absorptiometry. At fixator removal (T2), the pin-extraction strength was measured by the use of a digital-torque-wrench. Results: Two minor pin-track infections requiring oral antibiotics occurred in the HA-pin group (2.7%) (p > 0.05). The vast majority of clinical pin-site parameters were comparable in both groups. At the end of the fixator therapy, there were 16 loose pins (n(Ti6AL4V-group) = 10; n(HA-group) = 6). The rate of loose pins was correlated to patient's age (p < 0.05) but not to bone mineral density values or the occurrence of pin-site infection. Finally, no significant difference between the two groups was detected with regard to the prevalence of clinical relevant pin-site complications (p = 0.80). Conclusions: In external fixation of the wrist, the use of HA-coated pins yields no clinical advantages: there is a trend toward a superior pin-bone anchorage, but a tendency of increased susceptibility for minor pin-track infections.
引用
收藏
页码:845 / 851
页数:7
相关论文
共 50 条
  • [1] Hydroxyapatite-coated external fixation pins
    Moroni, A
    Pegreffi, F
    Cadossi, M
    Hoang-Kim, A
    Lio, V
    Giannini, S
    EXPERT REVIEW OF MEDICAL DEVICES, 2005, 2 (04) : 465 - 471
  • [2] Clinical benefit of hydroxyapatite-coated pins compared with stainless steel pins in external fixation at the wrist: A randomised prospective study
    Pieske, Oliver
    Kaltenhauser, Felicitas
    Pichlmaier, Leopold
    Schramm, Nicolai
    Trentzsch, Heiko
    Loeffler, Thomas
    Greiner, Axel
    Piltz, Stefan
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (10): : 1031 - 1036
  • [3] Titanium alloy pins versus stainless steel pins in external fixation at the wrist: A randomized prospective study
    Pieske, Oliver
    Geleng, Patrizia
    Zaspel, Johannes
    Piltz, Stefan
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 64 (05): : 1275 - 1280
  • [4] Fixation strength of tapered versus bicylindrical hydroxyapatite-coated external fixation pins: An animal study
    Moroni, A
    Faldini, C
    Pegreffi, F
    Giannini, S
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 63 (01): : 61 - 64
  • [5] Improving fixation strength in osteoporotic wrist fracture patients with hydroxyapatite-coated external fixation pins
    Moroni, A
    Faldini, C
    Marchetti, S
    Manca, M
    Consoli, V
    Giannini, S
    OSTEOPOROSIS INTERNATIONAL, 2002, 13 : S13 - S13
  • [6] A biomechanical and histological analysis of standard versus hydroxyapatite-coated pins for external fixation
    Moroni, Antonio
    Cadossi, Matteo
    Romagnoli, Matteo
    Faldini, Cesare
    Giannini, Sandro
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2008, 86B (02) : 417 - 421
  • [7] A comparison of hydroxyapatite-coated, titanium-coated, and uncoated tapered external-fixation pins -: An in vivo study in sheep
    Moroni, A
    Toksvig-Larsen, S
    Maltarello, MC
    Orienti, L
    Stea, S
    Giannini, S
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (04): : 547 - 554
  • [8] Hydroxyapatite coated external fixation pins - An experimental study
    Caja, VL
    Moroni, A
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (325) : 269 - 275
  • [9] Bisphosphonate-coated external fixation pins appear similar to hydroxyapatite-coated pins in the tibial metaphysis and to uncoated pins in the shaft A randomized trial
    Toksvig-Larsen, Soren
    Aspenberg, Per
    ACTA ORTHOPAEDICA, 2013, 84 (03) : 314 - 318
  • [10] Hydroxyapatite-coated pins dramatically improve the strength of fixation
    Moroni, A.
    Faldini, C.
    Vannini, F.
    Stigliano, V.
    Giannini, S.
    Key Engineering Materials, 2001, 192-195 : 1037 - 1042