Standardized evaluation method for electromagnetic tracking systems

被引:2
|
作者
Hummel, J
Jun, CM
Figl, M
Bax, M
Bergmann, H
Birkfellner, W
Shahidi, R
机构
关键词
D O I
10.1117/12.595256
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The major aim of this work was to define a protocol for evaluation of electromagnetic tracking systems (EMTS). Using this protocol we compared two commercial EMTS: the Ascension micro-BIRD (B) and NDI Aurora (A). To enable reproducibility and comparability of the assessments a machined base plate was designed, in which a 50 mm grid of holes is precision drilled for position measurements. A circle of 32 equispaced holes in the center enables the assessment of rotation. A small mount which fits into pairs of grid holes on the base plate is used to mount the sensor in a defined and rigid way. Relative positional/orientational errors are found by subtracting the known distances/rotations between the machined locations from the differences of the mean observed positions/rotation. To measure the influence of metallic objects we inserted rods (made of SST 303, SST 416, aluminum, and bronze) into the sensitive volume between sensor and emitter. Additionally the dynamic behavior was tested by using an optical sensor mounted on a spacer in a distance of 150 mm to the EXITS sensors. We found a relative positional error of 0.96mm +/- 0.68mm, range -0.06mm;2.23mm (A) and 1.14mm +/- 0.78mm, range -3.72mm-1.57mm(B) for a give distance of 50 mm. The positional jitter amounted to 0.14 mm(A)/ 0.20mm (B). The relative rotation error was found to be 1.81 degrees(A) / 0.63 degrees(B). For the dynamic behavior we calculated an error of 1.63mm(A)/1.93mm(B). The most relevant distortion caused by metallic objects results from SST 416. The maximum error 4.2mm(A)/41.9mm(B) occurs when the rod is close to the sensor(20mm).
引用
收藏
页码:236 / 240
页数:5
相关论文
共 50 条
  • [1] Evaluation of a new electromagnetic tracking system using a standardized assessment protocol
    Hummel, J
    Figl, M
    Birkfellner, W
    Bax, MR
    Shahidi, R
    Maurer, CR
    Bergmann, H
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (10): : N205 - N210
  • [2] Evaluation of rotation correction techniques for electromagnetic position tracking systems
    Kindratenko, V
    Bennett, A
    VIRTUAL ENVIRONMENTS 2000, 2000, : 13 - 22
  • [3] Electromagnetic Tracking for Tomotherapy Systems
    McGary, J. E.
    Chen, J.
    Xiong, Z.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S716 - S716
  • [4] Stability of miniature electromagnetic tracking systems
    Schicho, K
    Figl, M
    Donat, M
    Birkfellner, W
    Seemann, R
    Wagner, A
    Bergmann, H
    Ewers, R
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (09): : 2089 - 2098
  • [5] Standardized evaluation of haptic rendering systems
    Ruffaldi, Emanuele
    Morris, Dan
    Edmunds, Timothy
    Barbagli, Federico
    Pai, Dinesh K.
    SYMPOSIUM ON HAPTICS INTERFACES FOR VIRTUAL ENVIRONMENT AND TELEOPERATOR SYSTEMS 2006, PROCEEDINGS, 2006, : 225 - 232
  • [6] ESTABLISHMENT OF A STANDARDIZED DETERGENCY EVALUATION METHOD
    LINFIELD, WM
    JUNGERMANN, E
    SHERRILL, JC
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1962, 39 (01) : 47 - &
  • [8] EVALUATION OF INTERNATIONALLY STANDARDIZED METHOD FOR HAEMOGLOBINOMETRY
    MATSUBARA, T
    SHIBATA, S
    CLINICA CHIMICA ACTA, 1969, 23 (03) : 427 - +
  • [9] Evaluation Model and Method of Margin in Electromagnetic Environmental Effects for Complex Systems
    Tang Shiping
    Mao Junfa
    CHINESE JOURNAL OF ELECTRONICS, 2021, 30 (01) : 171 - 179
  • [10] Evaluation Model and Method of Margin in Electromagnetic Environmental Effects for Complex Systems
    TANG Shiping