Survival of Chondrocytes in Rabbit Septal Cartilage After Electromechanical Reshaping

被引:27
|
作者
Protsenko, Dmitry E. [1 ]
Ho, Kevin [2 ]
Wong, Brian J. F. [1 ]
机构
[1] Univ Calif Irvine, Beckman Laser Inst, Irvine, CA 92717 USA
[2] Stonestown Clin, San Francisco, CA 94132 USA
关键词
Cartilage reshaping; Chondrocytes; Tissue viability; Electrochemistry; ELECTROCHEMICAL TREATMENT; STRESS-RELAXATION; IN-VIVO; THERMAL-DAMAGE; LASER; VIABILITY; TUMORS; MODEL; GRAFTS; INJURY;
D O I
10.1007/s10439-010-0139-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Electromechanical reshaping (EMR) has been recently described as an alternative method for reshaping facial cartilage without the need for incisions or sutures. This study focuses on determining the short- and long-term viability of chondrocytes following EMR in cartilage grafts maintained in tissue culture. Flat rabbit nasal septal cartilage specimens were bent into semi-cylindrical shapes by an aluminum jig while a constant electric voltage was applied across the concave and convex surfaces. After EMR, specimens were maintained in culture media for 64 days. Over this time period, specimens were serially biopsied and then stained with a fluorescent live-dead assay system and imaged using laser scanning confocal microscopy. In addition, the fraction of viable chondrocytes was measured, correlated with voltage, voltage application time, electric field configuration, and examined serially. The fraction of viable chondrocytes decreased with voltage and application time. High local electric field intensity and proximity to the positive electrode also focally reduced chondrocyte viability. The density of viable chondrocytes decreased over time and reached a steady state after 2-4 weeks. Viable cells were concentrated within the central region of the specimen. Approximately 20% of original chondrocytes remained viable after reshaping with optimal voltage and application time parameters and compared favorably with conventional surgical shape change techniques such as morselization.
引用
收藏
页码:66 / 74
页数:9
相关论文
共 50 条
  • [1] Survival of Chondrocytes in Rabbit Septal Cartilage After Electromechanical Reshaping
    Dmitry E. Protsenko
    Kevin Ho
    Brian J. F. Wong
    Annals of Biomedical Engineering, 2011, 39 : 66 - 74
  • [2] Electromechanical reshaping of septal cartilage
    Ho, KHK
    Valdes, SHD
    Protsenko, DE
    Aguilar, G
    Wong, BJF
    LARYNGOSCOPE, 2003, 113 (11): : 1916 - 1921
  • [3] Changes in the Tangent Modulus of Rabbit Septal and Auricular Cartilage Following Electromechanical Reshaping
    Lim, Amanda
    Protsenko, Dmitry E.
    Wong, Brian J. F.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2011, 133 (09):
  • [4] Electromechanical reshaping of rabbit septal cartilage: a six needle electrode geometric configuration
    Wu, Edward C.
    Khan, Adam
    Protsenko, Dmitriy E.
    Dubin, Sterling
    Karimi, Koohyar
    Lim, Amanda
    Shaikh, Mohammad F.
    Li, Michael
    Wong, Brian J. F.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS V, 2009, 7161
  • [5] Needle-Electrode-Based Electromechanical Reshaping of Rabbit Septal Cartilage: A Systematic Evaluation
    Wu, Edward C.
    Protsenko, Dmitriy E.
    Khan, Adam Z.
    Dubin, Sterling
    Karimi, Koohyar
    Wong, Brian J. F.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (08) : 2378 - 2383
  • [6] In-Depth Analysis of pH-dependent Mechanisms of Electromechanical Reshaping of Rabbit Nasal Septal Cartilage
    Kuan, Edward C.
    Hamamoto, Ashley A.
    Manuel, Cyrus T.
    Protsenko, Dmitriy E.
    Wong, Brian J. F.
    LARYNGOSCOPE, 2014, 124 (10): : E405 - E410
  • [7] Using Optical Coherence Tomography to Monitor Effects of Electromechanical Reshaping in Septal Cartilage
    Chen, Heather
    Yu, Lingfeng
    Manuel, Cyrus
    Wong, Brian J. F.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS VI, 2010, 7548
  • [8] Stress relaxation in porcine septal cartilage during electromechanical reshaping: Mechanical and electrical responses
    Protsenko, DE
    Ho, K
    Wong, BJF
    ANNALS OF BIOMEDICAL ENGINEERING, 2006, 34 (03) : 455 - 464
  • [9] Stress Relaxation in Porcine Septal Cartilage During Electromechanical Reshaping: Mechanical and Electrical Responses
    Dmitriy E. Protsenko
    Kevin Ho
    Brian J. F. Wong
    Annals of Biomedical Engineering, 2006, 34 : 455 - 464
  • [10] Monitoring of electrical current in rabbit and porcine cartilage tissue during Electromechanical Reshaping
    Manuel, Cyrus T.
    Foulad, Allen
    Protsenko, Dmitriy E.
    Wong, Brian J. F.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS VI, 2010, 7548