Mitral Valve Morphology Assessment: Three-Dimensional Transesophageal Echocardiography Versus Computed Tomography

被引:41
|
作者
Shanks, Miriam
Delgado, Victoria
Ng, Arnold C. T.
van der Kley, Frank
Schuijf, Joanne D.
Boersma, Eric
van de Veire, Nico R. L.
Nucifora, Gaetano
Bertini, Matteo
de Roos, Albert
Kroft, Lucia
Schalij, Martin J.
Bax, Jeroen J. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Cardiol, NL-2333 ZA Leiden, Netherlands
来源
ANNALS OF THORACIC SURGERY | 2010年 / 90卷 / 06期
关键词
DOPPLER-ECHOCARDIOGRAPHY; ANNULAR GEOMETRY; CARDIAC CT; REGURGITATION; RECOMMENDATIONS; QUANTIFICATION; VALIDATION; EXPERIENCE; APPARATUS; STENOSIS;
D O I
10.1016/j.athoracsur.2010.06.116
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Advances in the minimally invasive mitral valve repair techniques increase the demands on accurate and reliable morphologic assessment of the mitral valve using three-dimensional imaging modalities. The present study compared mitral valve geometry measurements obtained by three-dimensional transesophageal echocardiography (TEE) to those obtained with multidetector row computed tomography (MDCT) used as a standard reference. Methods. Clinical preoperative MDCT and intraoperative three-dimensional TEE were performed in 43 patients (mean age 81.0 +/- 7.7 years) considered for transcatheter valve implantation procedure. Various measurements of mitral valve geometry were obtained from three-dimensional TEE datasets using mitral valve quantification software, and compared with those obtained from MDCT images using multiplanar reformation planes. Results. Moderate and severe mitral regurgitation was present in 48.9% of patients. There was good agreement in mitral valve geometry measurements between three-dimensional TEE and MDCT without significant overestimation or underestimation and tight 95% limits of agreement. For linear dimensions, angles and areas, the 95% limits of agreement were less than 1 cm, less than 15 degrees, and less than 2 cm(2), respectively. In addition, the intraclass correlation coefficients were more than 0.8 for all parameters. Finally, the measurements were highly reproducible, with low intraobserver and interobserver variability (nonsignificant overestimation or underestimation and narrow 95% limits of agreement). Conclusions. The present study demonstrates the accuracy and clinical feasibility of the assessment of the mitral valve geometry with three-dimensional TEE that is comparable to the MDCT measurements. Three-dimensional TEE and MDCT provide accurate and complementary information in the evaluation of patients with mitral valve disease. Its potential incremental clinical value in the field of transcatheter mitral repair procedures needs further assessment in the future studies. (Ann Thorac Surg 2010;90:1922-9) (C) 2010 by The Society of Thoracic Surgeons
引用
收藏
页码:1922 / 1929
页数:8
相关论文
共 50 条
  • [1] Mitral Annular Morphology in Mitral Valve Disease with Three-Dimensional Transesophageal Echocardiography
    Tani, Tomoko
    Kawai, Junichi
    Kitai, Takeshi
    Kim, Kitae
    Okada, Yukikatsu
    Kita, Toru
    Furukawa, Yutaka
    JOURNAL OF HEART VALVE DISEASE, 2014, 23 (02): : 193 - 199
  • [2] Mitral Valve Annulus Dimensions Assessment with Three-Dimensional Echocardiography Versus Computed Tomography: Implications for Transcatheter Interventions
    Hirasawa, Kensuke
    Vo, N. Mai
    Gegenava, Tea
    Pio, Stephan Milhorini
    van Wijngaarden, Suzanne E.
    Ajmone Marsan, Nina
    Bax, Jeroen J.
    Delgado, Victoria
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (04) : 1 - 8
  • [3] Three-dimensional reconstruction of mitral valve by transesophageal echocardiography
    Elmaghraby, Ahmed Mohamed
    Salustri, Alessandro
    HEART VIEWS, 2019, 20 (04): : 178 - 179
  • [4] Three-dimensional versus two-dimensional transesophageal echocardiography in mitral valve repair
    Garcia-Orta, Rocio
    Moreno, Eduardo
    Vidal, Matilde
    Ruiz-Lopez, Fuensanta
    Oyonarte, Jose M.
    Lara, Juan
    Moreno, Teodoro
    Garcia-Fernandezd, Miguel A.
    Azpitarte, Jose
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (01) : 4 - 12
  • [5] Quantitative Assessment of Mitral Valve Coaptation Using Three-Dimensional Transesophageal Echocardiography
    Cobey, Frederick C.
    Swaminathan, Madhav
    Phillips-Bute, Barbara
    Hyca, Martin
    Glower, Donald D.
    Douglas, Pamela S.
    Shaw, Andrew D.
    Mathew, Joseph P.
    Mackensen, G. Burkhard
    ANNALS OF THORACIC SURGERY, 2014, 97 (06): : 1998 - 2004
  • [6] SIMPLE AND COMPLEX MITRAL VALVE PROLAPSE: ASSESSMENT BY THREE-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    Vitarelli, Antonio
    Capotosto, Lidia
    Bich Lien Nguyen
    Tanzilli, Gaetano
    Viceconte, Nicola
    Mancone, Massimo
    Mangieri, Enrico
    Ciardi, Maria
    Mastroianni, Claudio
    Miraldi, Fabio
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 1281 - 1281
  • [7] Assessment of mitral prosthetic valve thrombosis by live three-dimensional echocardiography: comparison with transesophageal echocardiography
    Moreo, Antonella
    Lobiati, Elisabetta
    De Chiara, Benedetta
    Mauri, Francesco
    HEART AND VESSELS, 2007, 22 (04) : 287 - 289
  • [8] Assessment of mitral prosthetic valve thrombosis by live three-dimensional echocardiography: comparison with transesophageal echocardiography
    Antonella Moreo
    Elisabetta Lobiati
    Benedetta De Chiara
    Francesco Mauri
    Heart and Vessels, 2007, 22 : 287 - 289
  • [9] Live three-dimensional transesophageal echocardiography in mitral valve surgery
    MA NingLI ZhianMENG Xu and YANG Ya Department of Ultrasonography Department of Cardiac Surgery Beijing Anzhen HospitalCapital Medical UniversityBeijing China
    中华医学杂志(英文版), 2008, (20) : 2037 - 2041
  • [10] Three-dimensional transesophageal echocardiography in mitral valve repair and replacement
    Dzhanketova, V. S.
    Golukhova, E. Z.
    Mashina, T. V.
    Shamsiev, G. A.
    Mrikaev, D. V.
    EUROPEAN HEART JOURNAL, 2017, 38 : 412 - 413