INTERACTION DIAGRAMS AXIAL FORCE-BENDING MOMENT FOR FIRE EXPOSED STEEL-CONCRETE COMPOSITE SECTIONS

被引:0
|
作者
Milanovic, Milivoje [1 ]
Cvetkovska, Meri [2 ]
机构
[1] State Univ Novi Pazar, Dept Tech Sci, Novi Pazar, Serbia
[2] Ss Cyril & Methodius Univ, Fac Civil Engn, Skopje, Macedonia
关键词
composite column; temperature; heat transfer; fire resistance; interaction diagrams;
D O I
10.14311/asfe.2015.043
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The bearing capacity of the column cross section can be determined from the interaction diagram moment-axial force (M-N). Fire induced temperatures cause reduction of the load-bearing characteristics of the constitutive materials, steel and concrete, and this effect directly reflects on the reduction of the axial force and the bending moment that could be accepted by the column cross section, respectively the interaction diagram of the column cross section is changed. The load bearing capacity of the steel-concrete composite columns exposed to fire from all four sides and loaded by axial force and uni-axial or bi-axial bending moments, was estimated on the basis of the changes in the interaction diagrams moment-axial force amd the results are presented in this paper. Different types of composite columns made of totally or partially encased steel sections, or concrete filled hollow sections were analyzed and a detailed discussion on the effects of the shape of the cross section and the cross sectional dimensions are presented.