Measurement of uranium isotope ratios in solid samples using laser ablation and diode laser-atomic absorption spectrometry

被引:59
|
作者
Quentmeier, A [1 ]
Bolshov, M [1 ]
Niemax, K [1 ]
机构
[1] Inst Spectrochem & Appl Spectrochem, D-44139 Dortmund, Germany
关键词
laser ablation; diode laser atomic absorption; isotope ratio; uranium;
D O I
10.1016/S0584-8547(00)00289-5
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A diode laser was used for the selective detection of U-235 and U-238 in a laser-induced plasma ignited by a Nd:YAG laser beam focused onto uranium oxide samples. The diode laser was sequentially tuned to the absorption lines of both isotopes (682.6736 nm for U-235, and 682.6913 nm for U-238). The absorption was measured on a pulse-to-pulse basis; the transient absorption peak was used as an analytical signal. Three samples were used with the relative abundance of the minor isotope U-235 of 0.204%, 0.407% and 0.714%. Optimal conditions for the detection of the minor isotope were obtained at a distance of similar to 3 mm from the sample surface, an argon pressure of similar to 3 kPa and for 7.5 mJ pulse energy of the Nd:YAG laser. Absorption in the wing of the broadened line of the U-238 isotope was found to be the main source of background for the measurement of the absorption of the minor isotope. The limit of detection of the minor isotope, evaluated on the basis of the 3 sigma criteria was estimated to be 100 mug g(-1). At the optimal conditions for the detection of the minor isotope optical thick conditions in the line centre of the main isotope were observed. Therefore, the isotope ratio measurements were performed by rationing the intensity of the net absorption signal measured in the line centre of the minor isotope and the absorption signal measured in the wing of the main isotope. This strategy was checked by determination of the isotope ratios for the two samples with depleted U-235 concentration using the sample with the natural isotope composition (0.714%) as a standard. The accuracy and precision for this measurement strategy was evaluated to approximately 10%. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:45 / 55
页数:11
相关论文
共 50 条
  • [1] Diode laser absorption measurement of uranium isotope ratios in solid samples using laser ablation
    Liu, H
    Quentmeier, A
    Niemax, K
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (10) : 1611 - 1623
  • [2] Measurement of uranium isotope ratios in solid samples using laser ablation and diode laser-excited atomic fluorescence spectrometry
    Smith, BW
    Quentmeier, A
    Bolshov, M
    Niemax, K
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (06) : 943 - 958
  • [3] Measurement of uranium isotope ratio in solid sample by laser ablation and double-beam diode laser atomic absorption
    Liu, HT
    Zhang, ZX
    Quentmeier, A
    Niemax, K
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24 (10) : 1244 - 1247
  • [4] Accurate measurement of uranium isotope ratios in solid samples by laser ablation multi-collector inductively coupled plasma mass spectrometry
    Varga, Z.
    Krachler, M.
    Nicholl, A.
    Ernstberger, M.
    Wiss, T.
    Wallenius, M.
    Mayer, K.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (06) : 1076 - 1080
  • [5] Rubidium isotope measurements in solid samples by laser ablation-laser atomic absorption spectroscopy
    King, LA
    Gornushkin, IB
    Pappas, D
    Smith, BW
    Winefordner, JD
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (13) : 1771 - 1781
  • [6] Measurement of uranium isotope ratio by laser ablation absorption spectroscopy
    Ye Hao
    Huang Yin-Bo
    Wang Chen
    Liu Guo-Rong
    Lu Xing-Ji
    Cao Zhen-Song
    Huang Yao
    Qi Gang
    Mei Hai-Ping
    ACTA PHYSICA SINICA, 2021, 70 (16)
  • [7] Isotope selective element analysis by diode laser atomic absorption spectrometry
    H. D. Wizemann
    K. Niemax
    Microchimica Acta, 1998, 129 : 209 - 216
  • [8] Diode laser atomic absorption spectrometry
    Zybin, A
    Koch, J
    Wizemann, HD
    Franzke, J
    Niemax, K
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (01) : 1 - 11
  • [9] Isotope selective element analysis by diode laser atomic absorption spectrometry
    Wizemann, HD
    Niemax, K
    MIKROCHIMICA ACTA, 1998, 129 (3-4) : 209 - 216
  • [10] Laser ablation inductively coupled plasma mass spectrometry measurement of isotope ratios in depleted uranium contaminated soils
    Seltzer, MD
    APPLIED SPECTROSCOPY, 2003, 57 (09) : 1173 - 1177