Online molecular characterisation of organic aerosols in an atmospheric chamber using extractive electrospray ionisation mass spectrometry

被引:18
|
作者
Gallimore, Peter J. [1 ]
Giorio, Chiara [1 ,2 ]
Mahon, Brendan M. [1 ]
Kalberer, Markus [1 ]
机构
[1] Univ Cambridge, Dept Chem, Lensfield Rd, Cambridge CB2 1EW, England
[2] Univ Padua, Dipartimento Sci Chim, Via Marzolo 1, I-35131 Padua, Italy
基金
欧洲研究理事会; 英国工程与自然科学研究理事会; 英国自然环境研究理事会;
关键词
OF-THE-ART; REAL-TIME; ALPHA-PINENE; TROPOSPHERIC DEGRADATION; HIGH-RESOLUTION; PINONIC ACID; OLEIC-ACID; SECONDARY; OXIDATION; PRODUCTS;
D O I
10.5194/acp-17-14485-2017
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The oxidation of biogenic volatile organic compounds (VOCs) represents a substantial source of secondary organic aerosol (SOA) in the atmosphere. In this study, we present online measurements of the molecular constituents formed in the gas and aerosol phases during alpha-pinene oxidation in the Cambridge Atmospheric Simulation Chamber (CASC). We focus on characterising the performance of extractive electrospray ionisation (EESI) mass spectrometry (MS) for particle analysis. A number of new aspects of EESI-MS performance are considered here. We show that relative quantification of organic analytes can be achieved in mixed organic-inorganic particles. A comprehensive assignment of mass spectra for alpha-pinene derived SOA in both positive and negative ion modes is obtained using an ultra-high-resolution mass spectrometer. We compare these online spectra to conventional offline ESI-MS spectra and find good agreement in terms of the compounds identified, without the need for complex sample work-up procedures. Under our experimental conditions, EESI-MS signals arise only from particle-phase analytes. High-time-resolution (7 min) EESI-MS spectra are compared with simulations from the near-explicit Master Chemical Mechanism (MCM) for a range of reaction conditions. We show that MS peak abundances scale with modelled concentrations for condensable products (pinonic acid, pinic acid, OH-pinonic acid). Relative quantification is achieved throughout SOA formation as the composition, size and mass (5-2400 mu g m(-3)) of particles is evolving. This work provides a robust demonstration of the advantages of EESI-MS for chamber studies over offline ESI-MS (time resolution, relative quantification) and over "hard" online techniques (molecular information).
引用
收藏
页码:14485 / 14500
页数:16
相关论文
共 50 条
  • [1] Characterizing an Extractive Electrospray Ionization (EESI) Source for the Online Mass Spectrometry Analysis of Organic Aerosols
    Gallimore, Peter J.
    Kalberer, Markus
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (13) : 7324 - 7331
  • [2] Characterisation of intact microorganisms using electrospray ionisation mass spectrometry
    Goodacre, R
    Heald, JK
    Kell, DB
    FEMS MICROBIOLOGY LETTERS, 1999, 176 (01) : 17 - 24
  • [3] Characterisation of humic substances using atmospheric pressure chemical ionisation and electrospray ionisation mass spectrometry combined with size-exclusion chromatography
    Pfeifer, T
    Klaus, U
    Hoffmann, R
    Spiteller, M
    JOURNAL OF CHROMATOGRAPHY A, 2001, 926 (01) : 151 - 159
  • [4] Electrospray ionisation tandem mass spectrometry in the characterisation of isomeric benzofurocoumarins
    Begala, M
    Delogu, G
    Maccioni, E
    Podda, G
    Tocco, G
    Quezada, E
    Uriarte, E
    Fedrigo, MA
    Favretto, D
    Traldi, P
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (12) : 1000 - 1010
  • [5] Analysis of secondary organic aerosols in air using extractive electrospray ionization mass spectrometry (EESI-MS)
    Doezema, Lambert A.
    Longin, Teresa
    Cody, William
    Perraud, Veronique
    Dawson, Matthew L.
    Ezell, Michael J.
    Greaves, John
    Johnson, Kathleen R.
    Finlayson-Pitts, Barbara J.
    RSC ADVANCES, 2012, 2 (07) : 2930 - 2938
  • [6] Characterisation of sulphoxides by atmospheric pressure ionisation mass spectrometry
    Wright, P
    Alex, A
    Gibson, D
    Jones, R
    Macrae, P
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (14) : 2005 - 2014
  • [7] Understanding the mechanism of extractive electrospray ionization mass spectrometry for analyzing model secondary organic aerosols
    Longin, Teresa
    Kidd, Carla
    Wingen, Lisa
    Lyster, Kjertan
    Kumbhani, Sambhav
    Pitts, Barbara Finlayson
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251
  • [8] Characterisation of nicotine and related compounds using electrospray ionisation with ion trap mass spectrometry and with quadrupole time-of-flight mass spectrometry and their detection by liquid chromatography/electrospray ionisation mass spectrometry
    Smyth, Thomas J.
    Ramachandran, V. N.
    McGuigan, Alex
    Hopps, Jason
    Smyth, W. Franklin
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (04) : 557 - 566
  • [9] Comparison of extractive electrospray ionization mass spectrometry to other techniques for studying the composition of secondary organic aerosols
    Longin, Teresa
    Doezema, Lambert
    Cody, William
    Bruns, Emily
    Perraud, Veronique
    Ezell, Michael
    Dawson, Matthew
    Greaves, John
    Finlayson-Pitts, Barbara J.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 243
  • [10] Metabolic profiling using direct infusion electrospray ionisation mass spectrometry for the characterisation of olive oils
    Goodacre, R
    Vaidyanathan, S
    Bianchi, G
    Kell, DB
    ANALYST, 2002, 127 (11) : 1457 - 1462