This paper presents an efficient method to determine a body region-of-interest (ROI) enclosing a fetus in a two-dimensional (2D) key frame that removes some irrelevant matters such as the abdominal area in front of a fetus to visualize a fetal ultrasound volume along with the key frame. In the body ROI determination, a clear frontal view of a fetus lying down floating in amniotic fluid mainly depends on the successful determination of the top bound among the four bounds of an ROI The key idea of our top-bound setting is to locate it in amniotic fluid areas between a fetus and its mother's abdomen, which are dark so as to typically induce local minima of the vertical projection of a key frame. The support vector machines (SVM) classifier, known as an effective tool for classification, tests whether the candidate top bound, located at each of the local minima which are sorted in an increasing order, is valid or not. The test, using textural characterization of neighbor regions around each candidate bound, determines the first valid one as the top bound. The body ROI determination rate as well as resulting 3D images demonstrate that our system could replace a user in allocation of a fetus for its 3D visualization.
引用
收藏
页码:145 / 153
页数:9
相关论文
共 50 条
  • [1] Automatic localization of the fetal cerebellum on 3D ultrasound volumes
    Liu, Xinyu
    Yu, Jinhua
    Wang, Yuanyuan
    Chen, Ping
    MEDICAL PHYSICS, 2013, 40 (11)
  • [2] A fast 3D adaptive bilateral filter for ultrasound volume visualization
    Kwon, Koojoo
    Kim, Min-Su
    Shin, Byeong-Seok
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2016, 133 : 25 - 34
  • [3] Automatic Facial Axes Standardization of 3D Fetal Ultrasound Images
    Alomar, Antonia
    Rubio, Ricardo
    Salort, Laura
    Albaiges, Gerard
    Paya, Antoni
    Piella, Gemma
    Sukno, Federico
    SIMPLIFYING MEDICAL ULTRASOUND, ASMUS 2024, 2025, 15186 : 88 - 98
  • [4] VISUALIZATION OF 3D ULTRASOUND DATA
    NELSON, TR
    ELVINS, TT
    IEEE COMPUTER GRAPHICS AND APPLICATIONS, 1993, 13 (06) : 50 - 57
  • [5] Towards improved ultrasound-based analysis and 3D visualization of the fetal brain using the 3D Slicer
    Oyama, R.
    Jakab, M.
    Kikuchi, A.
    Sugiyama, T.
    Kikinis, R.
    Pujol, S.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2013, 42 (05) : 609 - 610
  • [6] 3D representation and volume determination of the prostate from ultrasound images
    CrivianuGaita, D
    Miclea, F
    Gaspar, A
    Margineantu, D
    Holban, S
    MEDICAL INFORMATICS EUROPE '96: HUMAN FACETS IN INFORMATION TECHNOLOGIES, 1996, 34 : 729 - 733
  • [7] Improving the visualization of 3D ultrasound data with 3D filtering
    Shamdasani, V
    Bae, U
    Managuli, R
    Kim, Y
    MEDICAL IMAGING 2005: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, PTS 1 AND 2, 2005, 5744 : 455 - 461
  • [8] 3D Ultrasound: Visualization of Volumetric Data
    L. V. Osipov
    N. S. Kulberg
    D. V. Leonov
    S. P. Morozov
    Biomedical Engineering, 2020, 54 : 149 - 154
  • [9] Deep Learning Segmentation, Visualization, and Automated 3D Assessment of Ciliary Body in 3D Ultrasound Biomicroscopy Images
    Minhaz, Ahmed Tahseen
    Sevgi, Duriye Damla
    Kwak, Sunwoo
    Kim, Alvin
    Wu, Hao
    Helms, Richard W.
    Bayat, Mahdi
    Wilson, David L.
    Orge, Faruk H.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (10):
  • [10] 3D Ultrasound: Visualization of Volumetric Data
    Osipov, L., V
    Kulberg, N. S.
    Leonov, D., V
    Morozov, S. P.
    BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2020, 54 (02): : 149 - 154