Feasibility and reliability of electrical, mechanical and thermal nociceptive testing and assessment of diffuse noxious inhibitory control in dogs

被引:3
|
作者
Ruel, Helene L. M. [1 ,2 ]
Watanabe, Ryota [1 ,2 ]
Evangelista, Marina C. [1 ,2 ]
Beauchamp, Guy [3 ]
Steagall, Paulo, V [1 ,2 ]
机构
[1] Univ Montreal, Fac Vet Med, Dept Clin Sci, 3200 Rue Sicotte, St Hyacinthe, PQ J2S 2M2, Canada
[2] Univ Montreal, Fac Vet Med, Quebec Anim Pharmacol Res Grp, St Hyacinthe, PQ, Canada
[3] Univ Montreal, Fac Vet Med, St Hyacinthe, PQ, Canada
来源
JOURNAL OF PAIN RESEARCH | 2018年 / 11卷
关键词
electrical threshold; mechanical threshold; thermal threshold; quantitative sensory testing; diffuse noxious inhibitory controls; canine; PAIN MODULATION; OSTEOARTHRITIS; REPEATABILITY; NEURONS; STIMULATION; PROTOCOL; RAT;
D O I
10.2147/JPR.S164483
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose: Quantitative sensory testing has been used to assess the somatosensory system. This study aimed to evaluate the feasibility and reliability of electrical (ENT), mechanical (MNT) and thermal (TNT) nociceptive testing and the effect of a conditioning stimulus on MNT. Patients and methods: Sixteen healthy client-owned dogs were included in this study. Stimulation was applied bilaterally to the dorsal and plantar aspect of the metacarpus and metatarsus respectively, using transcutaneous electrical stimulator, algometry and a cold nociceptive device in a randomized order until a behavior response was observed or a cut-off reached. Tests were performed twice (60 seconds apart) by two observers. Retesting was performed 5 hours later. The diffuse noxious inhibitory control was tested by comparing MNT pre- and post-conditioning stimuli. Sham-testing was performed for ENT and TNT. Statistical analysis included linear model and intra-class correlation coefficient (P<0.05). Results: Feasibility was 99% (ENT), 93.5% (MNT) and 93.6% (TNT). Data for TNT were not analyzed due to inconsistent results. Mean +/- SD were 48 +/- 22.6 mA (ENT) and 11.9 +/- 3.5 N (MNT). MNT was higher for thoracic than for pelvic limbs (P=0.002). Conditioning stimulus increased MNT (P=0.049). Inter-observer reliability was 91.4% (ENT) and 60.9% (MNT). False-positive responses were 15% (ENT) and 35.7% (TNT). Conclusion: ENT was feasible, repeatable and superior to MNT and TNT. The assessment of the diffuse noxious inhibitory control with a conditioning stimulus showed promising results in dogs. These tools could be used in naturally-occurring disease to provide insight on their underlying mechanisms and therapeutics.
引用
收藏
页码:2491 / 2496
页数:6
相关论文
共 5 条
  • [1] ENCODING OF NOCICEPTIVE THERMAL STIMULI BY DIFFUSE NOXIOUS INHIBITORY CONTROLS IN HUMANS
    WILLER, JC
    DEBROUCKER, T
    LEBARS, D
    JOURNAL OF NEUROPHYSIOLOGY, 1989, 62 (05) : 1028 - 1038
  • [2] Reliability of temporal summation and diffuse noxious inhibitory control
    Cathcart, Stuart
    Winefield, Anthony H.
    Rolan, Paul
    Lushington, Kurt
    PAIN RESEARCH & MANAGEMENT, 2009, 14 (06): : 433 - 438
  • [3] The CPM Effect: Functional Assessment of the Diffuse Noxious Inhibitory Control in Humans
    Leone, Caterina
    Truini, Andrea
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2019, 36 (06) : 430 - 436
  • [4] ASSESSMENT OF RELIABILITY OF ELECTRICAL AND THERMAL PULP TESTING AGENTS
    FUSS, Z
    TROWBRIDGE, H
    BENDER, IB
    RICKOFF, B
    SORIN, S
    JOURNAL OF ENDODONTICS, 1986, 12 (07) : 301 - 305
  • [5] Assessment of Sensory Thresholds in Dogs using Mechanical and Hot Thermal Quantitative Sensory Testing
    Cunningham, Rachael M.
    Park, Rachel M.
    Knazovicky, David
    Lascelles, B. Duncan X.
    Gruen, Margaret E.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2021, (176):