Use of balloon pull-through technique to assist in CardioSEAL device closure of patent foramen ovale

被引:12
|
作者
Chintala, K
Turner, DR
Leaman, S
Rodriguez-Cruz, E
Wynne, J
Greenbaum, A
Forbes, TJ
机构
[1] Wayne State Univ, Childrens Hosp Michigan, Cardiac Catheterizat Lab, Div Cardiol, Detroit, MI 48201 USA
[2] Wayne State Univ, Harper Hosp, Div Cardiol, Detroit, MI 48202 USA
[3] Henry Ford Hosp, Div Cardiol, Detroit, MI USA
关键词
heart defects; congenital; cerebrovascular accident; catheterization;
D O I
10.1002/ccd.10603
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
CardioSEAL device closure of patent foramen ovale (PFO) has been advocated for the treatment of patients with cryptogenic stroke. Using the standard delivery technique, partial deployment of the CardioSEAL device can occur, especially in patients with a thick septum secundum and/or long PFO tunnel. We hypothesized that using a left atrial-to-right atrial balloon pull-through to make the septum primum incompetent would result in improved final device position regardless of septal thickness or tunnel length. Catheterization reports, cineangiograms, and transesophageal echocardiograms of 51 patients who underwent CardioSEAL device closure of PFO between March 2000 and August 2002 were retrospectively reviewed. Group 1 (n = 21) included patients with CardioSEAL placement using the standard technique and group 2 (n = 30) included patients with CardioSEAL placement using the balloon pull-through technique. There were no differences between the groups in terms of age (43.6 vs. 45.3 years; P = NS), weight (83.3 vs. 89.9 kg; P = NS), septum secundum thickness (6.4 vs. 7.0 mm; P = NS), PFO tunnel length (15.5 vs. 13.1 mm; P = NS), or device size. In group 1, 4/21 (19%) had partial deployment of the CardioSEAL device, while in group 2, no partial CardioSEAL deployment (0/30) was observed. No complications were associated with the balloon pull-through technique. We conclude that the left atrial-to-right atrial balloon pull-through technique is safe and may allow for better final position of the CardioSEAL device during PFO closure. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:101 / 106
页数:6
相关论文
共 50 条
  • [1] Use of a Second Device for the Closure of Patent Foramen Ovale
    Cruz-Gonzalez, Ignacio
    Diaz, Tulio A.
    Inglessis-Azuaje, Ignacio
    Palacios, Igor F.
    REVISTA ESPANOLA DE CARDIOLOGIA, 2010, 63 (11): : 1384 - 1386
  • [2] Utility of quantitative and qualitative intracardiac echocardiography during CardioSeal Device closure of patent Foramen ovale
    Liu, Z
    Roukoz, B
    Surabhi, S
    Kuersten, B
    Puri, T
    Goldberg, S
    Vannan, M
    McCormick, D
    CIRCULATION, 2002, 106 (19) : 705 - 705
  • [3] Percutaneous closure of patent foramen ovale using the CardioSEAL-STARFlex
    Reschke, M
    Ostermayer, S
    Bayard, Y
    Büscheck, F
    Billinger, K
    Trepels, T
    Sievert, H
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (6A): : 13L - 13L
  • [4] Infective Endocarditis of a Completely Endothelialized CardioSEAL Patent Foramen Ovale Closure Device - Extremely Rare Entity -
    Sharma, Gaurav K.
    Samoon, Quratulain A.
    Abbasi, Taimur
    Tripathi, Angie
    Kumar, Amit
    O'Keefe, Conner
    Dasgupta, Arijit
    Gasior, Robert
    Jones, Paul A.
    CIRCULATION JOURNAL, 2017, 81 (09) : 1373 - 1374
  • [5] Closure of patent foramen ovale with CardioSEAL septal occluder: A safe intervention.
    Sommer, RJ
    Kramer, PH
    Sorensen, SG
    Forbes, T
    O'Donnell, M
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (6A): : 136H - 136H
  • [6] Patent Foramen Ovale Stroke and Device Closure
    Suradi, Hussam S.
    Hijazi, Ziyad M.
    CARDIOLOGY CLINICS, 2016, 34 (02) : 231 - +
  • [7] Sizing of patent ductus arteriosus in adults for transcatheter closure using the balloon pull-through technique
    Shafi, Nabil A.
    Singh, Gagan D.
    Smith, Thomas W.
    Rogers, Jason H.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 91 (06) : 1159 - 1163
  • [8] Device Closure for Stroke with Patent Foramen Ovale
    Dani, Sourbha
    Singh, Aniruddha
    Trivedi, Nitin
    NEW ENGLAND JOURNAL OF MEDICINE, 2012, 366 (24): : 2323 - 2323
  • [9] The BioSTAR® device versus the CardioSEAL® device in patent foramen ovale closure: comparison of mid-term efficacy and safety
    Van den Branden, Ben D.
    Luermans, Justin G.
    Post, Martijn C.
    Plokker, Herbert W.
    ten Berg, Jurrien M.
    Suttorp, Maarten J.
    EUROINTERVENTION, 2010, 6 (04) : 498 - 504
  • [10] Catheter closure of patent foramen ovale:: Single center experience with the cardioseal and the new cardioseal-starflex occluder
    Sievert, H
    Krumsdorf, U
    Horvath, K
    Keppeler, P
    Schäder, R
    Fach, A
    Merle, H
    Spies, H
    Scherer, D
    Ensslen, R
    Zeplin, H
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 53A - 53A