Multiplex measurement of proinflammatory cytokines in human serum: Comparison of the Meso Scale Discovery electrochemiluminescence assay and the Cytometric Bead Array
被引:117
|
作者:
Dabitao, Djeneba
论文数: 0引用数: 0
h-index: 0
机构:
Johns Hopkins Bloomberg Sch Publ Hlth, W Harry Feinstone Dept Mol Microbiol & Immunol, Baltimore, MD 21205 USAJohns Hopkins Bloomberg Sch Publ Hlth, W Harry Feinstone Dept Mol Microbiol & Immunol, Baltimore, MD 21205 USA
Dabitao, Djeneba
[1
]
Margolick, Joseph B.
论文数: 0引用数: 0
h-index: 0
机构:
Johns Hopkins Bloomberg Sch Publ Hlth, W Harry Feinstone Dept Mol Microbiol & Immunol, Baltimore, MD 21205 USAJohns Hopkins Bloomberg Sch Publ Hlth, W Harry Feinstone Dept Mol Microbiol & Immunol, Baltimore, MD 21205 USA
Margolick, Joseph B.
[1
]
Lopez, Joseph
论文数: 0引用数: 0
h-index: 0
机构:
Johns Hopkins Bloomberg Sch Publ Hlth, W Harry Feinstone Dept Mol Microbiol & Immunol, Baltimore, MD 21205 USAJohns Hopkins Bloomberg Sch Publ Hlth, W Harry Feinstone Dept Mol Microbiol & Immunol, Baltimore, MD 21205 USA
Lopez, Joseph
[1
]
Bream, Jay H.
论文数: 0引用数: 0
h-index: 0
机构:
Johns Hopkins Bloomberg Sch Publ Hlth, W Harry Feinstone Dept Mol Microbiol & Immunol, Baltimore, MD 21205 USAJohns Hopkins Bloomberg Sch Publ Hlth, W Harry Feinstone Dept Mol Microbiol & Immunol, Baltimore, MD 21205 USA
Bream, Jay H.
[1
]
机构:
[1] Johns Hopkins Bloomberg Sch Publ Hlth, W Harry Feinstone Dept Mol Microbiol & Immunol, Baltimore, MD 21205 USA
Serum cytokine profiling is a powerful tool to link host immune defense with disease pathogenesis. Although several multiplex assays are commercially available, none has been rigorously validated in the context of chronic infectious disease (such as HIV infection). Here we compared the measurement of proinflammatory cytokines by two multiplex platforms: the Meso Scale Discovery (MSD) electrochemiluminescence assay and the Becton Dickinson Cytometric Bead Array (CBA) flow cytometric assay, using serum samples from HIV-infected and -uninfected donors. We evaluated the ability of these assays to: a) quantify circulating levels of native cytokines (IL-6, IL-8, IL-10, TNF-alpha, IL-12p70, IL-1 beta), and b) accurately recover known amounts of recombinant cytokines added to serum samples. Based on the standard curves, the sensitivity of the MSD system was only slightly better than the CBA. However, in serum the MSD platform consistently quantified levels of endogenous IL-12p70. TNF-alpha, and IL-10 that were undetectable by the CBA assay. The MSD assay was also more accurate as determined by an enhanced capacity to recover known concentrations of recombinant cytokines added to serum. Both assays performed equally well in quantifying IL-6 and IL-8, while neither assay quantified IL-1 beta with accuracy and precision. Interestingly, HIV infection did not affect the performance of either assay. Overall, the MSD assay provided a more reliable assessment of the proinflammatory cytokines tested in the serum of healthy and HIV-infected individuals. (C) 2011 Elsevier B.V. All rights reserved.
机构:
Teva Branded Pharmaceut R&D Inc, Biomarker & Metab Analyt, W Chester, PA 19380 USATeva Branded Pharmaceut R&D Inc, Biomarker & Metab Analyt, W Chester, PA 19380 USA
Liu, Yun
Robinson, Ronald
论文数: 0引用数: 0
h-index: 0
机构:
Teva Branded Pharmaceut R&D Inc, Biomarker & Metab Analyt, W Chester, PA 19380 USATeva Branded Pharmaceut R&D Inc, Biomarker & Metab Analyt, W Chester, PA 19380 USA
Robinson, Ronald
Ung, Thao
论文数: 0引用数: 0
h-index: 0
机构:
Teva Branded Pharmaceut R&D Inc, Biomarker & Metab Analyt, W Chester, PA 19380 USATeva Branded Pharmaceut R&D Inc, Biomarker & Metab Analyt, W Chester, PA 19380 USA
Ung, Thao
Spais, Chrysanthe
论文数: 0引用数: 0
h-index: 0
机构:
Teva Branded Pharmaceut R&D Inc, Specialty Bioanalyt, W Chester, PA 19380 USATeva Branded Pharmaceut R&D Inc, Biomarker & Metab Analyt, W Chester, PA 19380 USA
Spais, Chrysanthe
Schreiber, Justin
论文数: 0引用数: 0
h-index: 0
机构:
Teva Branded Pharmaceut R&D Inc, Specialty Bioanalyt, W Chester, PA 19380 USATeva Branded Pharmaceut R&D Inc, Biomarker & Metab Analyt, W Chester, PA 19380 USA
Schreiber, Justin
Lyons, Jacquelyn
论文数: 0引用数: 0
h-index: 0
机构:
Teva Branded Pharmaceut R&D Inc, Bioassay Biosci, W Chester, PA 19380 USATeva Branded Pharmaceut R&D Inc, Biomarker & Metab Analyt, W Chester, PA 19380 USA
Lyons, Jacquelyn
Husten, Jean
论文数: 0引用数: 0
h-index: 0
机构:
Teva Branded Pharmaceut R&D Inc, Bioassay Biosci, W Chester, PA 19380 USATeva Branded Pharmaceut R&D Inc, Biomarker & Metab Analyt, W Chester, PA 19380 USA
Husten, Jean
Hallak, Hussein
论文数: 0引用数: 0
h-index: 0
机构:
Nonclin Dev Teva Pharmaceut Ind Ltd, 19 Giborey Israel, IL-42504 St Netanya, IsraelTeva Branded Pharmaceut R&D Inc, Biomarker & Metab Analyt, W Chester, PA 19380 USA
Hallak, Hussein
Angeles, Thelma
论文数: 0引用数: 0
h-index: 0
机构:
Teva Branded Pharmaceut R&D Inc, Biomarker & Metab Analyt, W Chester, PA 19380 USATeva Branded Pharmaceut R&D Inc, Biomarker & Metab Analyt, W Chester, PA 19380 USA