Optical verification and in-vitro characterization of two commercially available acoustic bubble counters for cardiopulmonary bypass systems

被引:16
|
作者
Segers, Tim [1 ,2 ]
Stehouwer, Marco C. [3 ]
de Somer, Filip M. J. J. [4 ]
de Mol, Bastian A. [5 ]
Versluis, Michel [1 ,2 ]
机构
[1] Univ Twente, MESA Inst Nanotechnol, Phys Fluids Grp, Enschede, Netherlands
[2] Univ Twente, MIRA Inst Biomed Technol & Tech Med, Enschede, Netherlands
[3] St Antonius Hosp, Dept Extracorporeal Circulat, Utrecht, Netherlands
[4] Univ Ghent, Ctr Heart, Ghent, Belgium
[5] Tech Univ Eindhoven, Fac Biomed Technol, Sect Cardiovasc Biomech, Eindhoven, Netherlands
来源
PERFUSION-UK | 2018年 / 33卷 / 01期
关键词
GME; cardiopulmonary bypass; bubble counter; microbubble; emboli; validation; MICROEMBOLI; EMBOLIZATION; CIRCUITS; FILTER;
D O I
10.1177/0267659117722595
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Gaseous microemboli (GME) introduced during cardiac surgery are considered as a potential source of morbidity, which has driven the development of the first bubble counters. Two new generation bubble counters, introduced in the early 2000s, claim correct sizing and counting of GME. This in-vitro study aims to validate the accuracy of two bubble counters using monodisperse bubbles in a highly controlled setting at low GME concentrations. Methods: Monodisperse GME with a radius of 43 mu m were produced in a microfluidic chip. Directly after their formation, they were injected one-by-one into the BCC200 and the EDAC sensors. GME size and count, measured with the bubble counters, were optically verified using high-speed imaging. Results: During best-case scenarios or low GME concentrations of GME with a size of 43 mu m in radius in an in-vitro setup, the BCC200 overestimates GME size by a factor of 2 to 3 while the EDAC underestimates the average GME size by at least a factor of two. The BCC200 overestimates the GME concentration by approximately 20% while the EDAC overestimates the concentration by nearly one order of magnitude. Nevertheless, the calculated total GME volume is only over-predicted by a factor 2 since the EDAC underestimates the actual GME size. For the BCC200, the total GME volume was over-predicted by 25 times due to the over-estimation of GME size. Conclusions: The measured errors in the absolute sizing/counting of GME do not imply that all results obtained using the bubble counters are insignificant or invalid. A relative change in bubble size or bubble concentration can accurately be measured. However, care must be taken in the interpretation of the results and their absolute values. Moreover, the devices cannot be used interchangeably when reporting GME activity. Nevertheless, both devices can be used to study the relative air removal characteristics of CPB components or for the quantitative monitoring of GME production during CPB interventions.
引用
收藏
页码:16 / 24
页数:9
相关论文
共 10 条
  • [1] ANALYSIS OF THE PRESSURE WAVEFORM PRODUCED BY TWO COMMERCIALLY AVAILABLE BUBBLE CPAP SYSTEMS
    Shearman, A.
    INTENSIVE CARE MEDICINE, 2013, 39 : S165 - S165
  • [2] In-vivo and in-vitro histological evaluation of two commercially available acellular dermal matrices
    J. A. Faleris
    R. M. C. Hernandez
    D. Wetzel
    R. Dodds
    D. C. Greenspan
    Hernia, 2011, 15 : 147 - 156
  • [3] In-vivo and in-vitro histological evaluation of two commercially available acellular dermal matrices
    Faleris, J. A.
    Hernandez, R. M. C.
    Wetzel, D.
    Dodds, R.
    Greenspan, D. C.
    HERNIA, 2011, 15 (02) : 147 - 156
  • [4] Comparison of Physiochemical Properties and Biocompatiblity of Two Commercially Available Natural Xenogeneic Collagen Membranes: In-vitro Study
    Gnanamani, A.
    Lavu, Vamsi
    Joseph, Reshma Achu
    Thilagam, R.
    Balaji, S. K.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2024, 18 (08) : ZC30 - ZC35
  • [5] In vitro evaluation of the strength of the conical implant-to-abutment joint in two commercially available implant systems
    Norton, MR
    JOURNAL OF PROSTHETIC DENTISTRY, 2000, 83 (05): : 567 - 571
  • [6] Dosimetric verification of two commercially available three-dimensional treatment planning systems using the TG 23 test package
    Ramsey, CR
    Cordrey, IL
    Spencer, KM
    Oliver, AL
    MEDICAL PHYSICS, 1999, 26 (07) : 1188 - 1195
  • [7] In-Vitro Evaluation of Two Types of Neonatal Oxygenators in Handling Gaseous Microemboli and Maintaining Optimal Hemodynamic Stability During Cardiopulmonary Bypass
    Marupudi, Neelima
    Wang, Shigang
    Caneo, Luiz Fernando
    Jatene, Fabio Biscegli
    Kunselman, Allen R.
    Undar, Akif
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2016, 31 (05) : 343 - 350
  • [8] In vitro air removal characteristics of two neonatal cardiopulmonary bypass systems: filtration may lead to fractionation of bubbles
    Stehouwer, Marco C.
    Kelder, Johannes C.
    van Oeveren, Willem
    de Vroege, Roel
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2014, 37 (09): : 688 - 696
  • [9] Characterization of the environmental quality of sediments from two estuarine systems based on different in-vitro bioassays
    Fernandes, Denise
    Pujol, Silvia
    Perez-Albaladejo, Elisabet
    Tauler, Roma
    Bebianno, Maria Joao
    Porte, Cinta
    MARINE ENVIRONMENTAL RESEARCH, 2014, 96 : 127 - 135
  • [10] Commercially available media for flushing extracorporeal bioartificial liver systems prior to connection to the patient's circulation:: an in vitro comparative study in two and three dimensional porcine hepatocyte cultures
    Flendrig, LM
    Sommeijer, D
    Ladiges, NCJJ
    Velde, AAT
    Maas, MAW
    Jörning, GGA
    Daalhuisen, J
    Chamuleau, RAFM
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1998, 21 (08): : 467 - 472