Hazard analysis of EUCLIDIAN: An image-guided robotic brachytherapy system

被引:2
|
作者
Hu, Yida [1 ]
Podder, Tarun [1 ]
Buzurovic, Ivan [1 ]
Yan, Kaiguo [1 ]
Ng, Wan Sing [2 ]
Yu, Yan [1 ]
机构
[1] Thomas Jefferson Univ, Jefferson Med Coll, Dept Radiat Oncol, Philadelphia, PA 19107 USA
[2] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
关键词
D O I
10.1109/IEMBS.2007.4352523
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Robotic assistance can help clinicians to improve the flexibility of needle insertion and accuracy of seed deposition. However, the robotic platform is a safety critical system for its automated operational mode. Thus, it is important to perform Hazard Identification & Safety Insurance Control (HISIC) for securing the safety of a medical robotic system. In this paper, we have performed HISIC for our robotic platform, called Endo-Uro Computer Lattice for Intratumoral Delivery, Implementation, and Ablation with Nanosensing (ECLIDIAN) The definition and requirements of the system are described by Unified Modeling Language (UML). Failure Mode and Effect Analysis (FMEA) are executed for the principles of HISIC, such as hazard identification, safety insurance control, safety critical limit, monitoring and control. FMEA combined with UML can also be implemented to ensure reliability of the human operation. On the basis of safety control index and fuzzy mathematics, safety effective value is outlined to assess the validity of safety insurance control for robotic system. The above principles and methods are feasible and effective for hazard analysis during the development of the robotic system.
引用
收藏
页码:1249 / +
页数:2
相关论文
共 50 条
  • [1] Reliability of EUCLIDIAN: An autonomous robotic system for image-guided prostate brachytherapy
    Podder, Tarun K.
    Buzurovic, Ivan
    Huang, Ke
    Showalter, Timothy
    Dicker, Adam P.
    Yu, Yan
    MEDICAL PHYSICS, 2011, 38 (01) : 96 - 106
  • [2] An image-guided robotic system for prostate brachytherapy
    Yu, Y.
    Podder, T. K.
    Ng, W.
    Messing, E. M.
    Rubens, D. J.
    Strang, J. G.
    Brasacchio, R. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S699 - S699
  • [3] Calibration of Image-Guided Robotic System for Prostate Brachytherapy
    Buzurovic, I.
    Podder, T.
    Hu, Y.
    Yan, K.
    Valicenti, R.
    Dicker, A.
    Yu, Y.
    MEDICAL PHYSICS, 2008, 35 (06) : 2970 - +
  • [4] Practical Quality Assurance for Image-Guided Robotic Brachytherapy System
    Buzurovic, I.
    Podder, T.
    Yu, Y.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [5] A robotic platform for image-guided brachytherapy (IGBT)
    Yu, Y.
    Podder, T.
    Zhang, Y.
    Ng, W.
    Sherman, J.
    Fuller, D.
    Fu, L.
    Misic, V.
    Messing, E.
    Rubens, D.
    Strang, J.
    Brasacchio, R.
    MEDICAL PHYSICS, 2006, 33 (06) : 2061 - 2061
  • [6] Image-guided brachytherapy
    Villafranca, E.
    Romero, P.
    Sola, A.
    Asin, G.
    Rico, M.
    Vila, M. T.
    ANALES DEL SISTEMA SANITARIO DE NAVARRA, 2009, 32 : 51 - 59
  • [7] Image-guided robotic navigation system for neurosurgery
    Tseng, CS
    Chen, HH
    Wang, SS
    Tseng, HM
    JOURNAL OF ROBOTIC SYSTEMS, 2000, 17 (08): : 439 - 447
  • [8] MR image-guided surgical robotic system
    Hashizume, M.
    Yasunaga, T.
    Konishi, K.
    Ieiri, S.
    Tanoue, K.
    Kishi, K.
    Nakamoto, H.
    Ikeda, D.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2006, 1 : 203 - 205
  • [9] Image-guided robotic system for therapeutic delivery
    Yu, Y.
    Podder, T.
    Zhang, Y. D.
    Ng, W. S.
    Messing, E.
    Rubens, DJ.
    Strang, J.
    Brasacchio, R.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S197 - S198
  • [10] Advances in Image-Guided Brachytherapy
    Tanderup, Kari
    El Naga, Issam
    Carlson, David J.
    Klein, Eric E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 97 (05): : 873 - 875