Continuous Performance Test assessed with time-domain functional Near Infrared Spectroscopy

被引:0
|
作者
Torricelli, Alessandro [1 ]
Contini, Davide [1 ]
Spinelli, Lorenzo [1 ]
Caffini, Matteo [1 ]
Butti, Michele [2 ]
Baselli, Giuseppe [2 ]
Bianchi, Anna Maria [2 ]
Bardoni, Alessandra [3 ]
Cerutti, Sergio [2 ]
Cubeddu, Rinaldo [1 ]
机构
[1] CNR, INFM, ULTRAS, IIT, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
[2] Politecn Milan, Dipartimento Bioingn, I-20133 Milan, Italy
[3] IRCCS E Medea, Neuroriabilitat Unit, I-23842 Bosisio Parini, Lecco, Italy
来源
关键词
photon migration; medical optics instrumentation; time-resolved imaging; Blood/tissue constituent monitoring;
D O I
10.1117/12.727952
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A time-domain fNIRS multichannel system was used in a sustained attention protocol (continuous performance test) to study activation of the prefrontal cortex. Preliminary results on volounteers show significant activation (decrease in deoxy-hemoglobin and increase in oxy-hemoglobin) in both left and right prefrontal cortex.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Continuous time-domain analysis of cerebrovascular autoregulation using near-infrared spectroscopy
    Brady, Ken M.
    Lee, Jennifer K.
    Kibler, Kathleen K.
    Smielewski, Piotr
    Czosnyka, Marek
    Easley, R. Blaine
    Koehler, Raymond C.
    Shaffner, Donald H.
    STROKE, 2007, 38 (10) : 2818 - 2825
  • [2] Reduced frontal functional asymmetry in schizophrenia during a cued continuous performance test assessed with near-infrared spectroscopy
    Fallgatter, AJ
    Strik, WK
    SCHIZOPHRENIA BULLETIN, 2000, 26 (04) : 913 - 919
  • [3] Miniaturized Probe for Time-Domain Near-Infrared Spectroscopy
    Saha, Sreenil
    Lu, Yuankang
    Weyers, Sascha
    Lesage, Frederic
    Sawan, Mohamad
    2018 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS): ADVANCED SYSTEMS FOR ENHANCING HUMAN HEALTH, 2018, : 323 - 326
  • [4] Time-Domain Near-Infrared Spectroscopy and Imaging: A Review
    Yamada, Yukio
    Suzuki, Hiroaki
    Yamashita, Yutaka
    APPLIED SCIENCES-BASEL, 2019, 9 (06):
  • [5] Multimodal analysis of a sustained attention protocol: Continuous performance test assessed with near infrared spectroscopy and EEG
    Butti, Michele
    Pastori, Aurora
    Merzagora, Anna
    Zucca, Claudio
    Bianchi, Anna
    Reni, Gianluigi
    Cerutti, Sergio
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 3596 - +
  • [6] Cerebral time-domain near-infrared spectroscopy for clinical use
    Lange, Frederic
    FRONTIERS IN BIOPHOTONICS AND IMAGING, 2021, 11879
  • [7] Reliability of brain metrics derived from a Time-Domain Functional Near-Infrared Spectroscopy System
    Dubois, Julien
    Field, Ryan M.
    Jawhar, Sami
    Koch, Erin M.
    Aghajan, Zahra M.
    Miller, Naomi
    Perdue, Katherine L.
    Taylor, Moriah
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [8] Combining near infrared spectroscopy and functional MRI during continuous performance test in healthy subjects
    Butti, Michele
    Pastori, Aurora
    Merzagora, Anna
    Bianchi, Anna
    Bardoni, Alessandra
    Branca, Vincenzo
    Costa, Antonella
    Cerutti, Sergio
    Reni, Gianluigi
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 3836 - +
  • [9] Right frontal activation during the continuous performance test assessed with near-infrared spectroscopy in healthy subjects
    Fallgatter, AJ
    Strik, WK
    NEUROSCIENCE LETTERS, 1997, 223 (02) : 89 - 92
  • [10] Performance and reproducibility assessment across multiple time-domain near-infrared spectroscopy device replicas
    Lacerenza, M.
    Torricelli, A.
    Tosi, A.
    Contini, D.
    Dalla Mora, A.
    Pifferi, A.
    Zappa, F.
    Buttafava, M.
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES XV, 2022, 11951