A comparison of on-line hemodiafiltration and high-flux hemodialysis: A prospective clinical study

被引:1
|
作者
Ward, RA
Schmidt, S
Hullin, J
Hillebrand, GF
Samtleben, W
机构
[1] Univ Louisville, Kidney Dis Program, Dept Med, Louisville, KY 40202 USA
[2] Univ Munich, Klinikum Grosshadern, Dept Med 1, D-8000 Munich, Germany
[3] Kuratorium Dialyse & Nierentransplantat, Neuried, Germany
来源
关键词
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Some of the morbidity associated with chronic hemodialysis is thought to result from retention of large molecular weight solutes that are poorly removed by diffusion in conventional hemodialysis. Hemodiafiltration combines convective and diffusive solute removal in a single therapy. The hypothesis that hemodiafiltration provides better solute removal than high-flux hemodialysis was tested in a prospective, randomized clinical trial. Patients were randomized to either on-line postdilution hemodiafiltration or high-flux hemodialysis. The groups did not differ in body size, treatment time, blood flow rate, or net fluid removal. The filtration volume in hemodiafiltration was 21 +/- 1 L. Therapy prescriptions were unchanged for a 12-mo study period. Removal of both small (urea and creatinine) and large (beta (2)-microglobulin and complement factor D) solutes was significantly greater for hemodiafiltration than for high-flux hemodialysis. The increased urea and creatinine removal did not result in lower pretreatment serum concentrations in the hemodiafiltration group. Pretreat ment plasma beta (2)-microglobulin concentrations decreased with time (P < 0 0.001); however, the decrease was similar for both therapies (P = 0.317). Pretreatment plasma complement factor D concentrations also decreased with time (P < 0.001), and the decrease was significantly greater with hemodiafiltration than with high-flux hemodialysis (P = 0.010). The conclusion is that on-line hemodiafiltration provides superior solute removal to high-flux hemodialysis over a wide molecular weight range. The improved removal may not result in lower pretreatment plasma concentrations, however, possibly because of limitations in mass transfer rates within the body.
引用
收藏
页码:2344 / 2350
页数:7
相关论文
共 50 条
  • [1] Infective spondylodiscitis in patients on high-flux hemodialysis and on-line hemodiafiltration
    Abid, Saima
    De Silva, Shamila
    Warwicker, Paul
    Farrington, Ken
    HEMODIALYSIS INTERNATIONAL, 2008, 12 (04) : 463 - 470
  • [2] Vancomycin hemodialysis: Clearance differences between high-flux hemodialysis and on-line hemodiafiltration
    Rodriguez, Nestor
    Gomez, Miquel
    Rico, Naira
    Maria Campistol, Josep
    Maduell, Francisco
    ARTIFICIAL ORGANS, 2019, 43 (03) : 261 - 269
  • [3] On-line hemodiafiltration:: Comparison of eleven different high-flux dialyzers
    Maduell, F
    Navarro, V
    Hernández-Jaras, J
    Calvo, C
    NEFROLOGIA, 2000, 20 (03): : 269 - 276
  • [4] The effects of on-line hemodiafiltration on oxidative stress and β2-microglobulin in comparison with high-flux hemodialysis
    Kim, DK
    Kim, HJ
    Kim, HJ
    Ryu, DR
    Kang, SW
    Choi, KH
    Lee, HY
    Han, DS
    Kang, EW
    Shin, SK
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2005, 20 : V126 - V126
  • [5] High-Flux Dialysis: Clinical, Biochemical, and Proteomic Comparison with Low-Flux Dialysis and On-Line Hemodiafiltration
    Donadio, Carlo
    Kanaki, Angeliki
    Sami, Nadia
    Tognotti, Danika
    BLOOD PURIFICATION, 2017, 44 (02) : 129 - 139
  • [6] Osteocalcin and myoglobin removal in on-line hemodiafiltration versus low- and high-flux hemodialysis
    Maduell, F
    Navarro, V
    Cruz, MC
    Torregrosa, E
    Garcia, D
    Simon, V
    Ferrero, JA
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2002, 40 (03) : 582 - 589
  • [7] Efficacy of Convective-Controlled Double High-Flux Hemodiafiltration versus On-Line Hemodiafiltration: 1-Year Prospective Study
    Susantitaphong, Paweena
    Tiranathanagul, Khajohn
    Katavetin, Pisut
    Townamchai, Natavudh
    Praditpornsilpa, Kearkiat
    Tungsanga, Kriang
    Eiam-Ong, Somchai
    BLOOD PURIFICATION, 2010, 29 (01) : 35 - 43
  • [8] Comparison between On-Line High-Efficiency Hemodiafiltration and Conventional High-Flux Hemodialysis for Polyclonal Free Light Chain Removal
    Lamy, Thomas
    Henri, Patrick
    Lobbedez, Thierry
    Comby, Elisabeth
    Ryckelynck, Jean-Philippe
    Ficheux, Maxence
    BLOOD PURIFICATION, 2014, 37 (02) : 93 - 98
  • [9] Comparison of middle-molecule clearance between convective control double high-flux hemodiafiltration and on-line hemodiafiltration
    Tiranathanagul, K.
    Yossundharakul, C.
    Techawathanawanna, N.
    Katavetin, P.
    Hanvivatvong, O.
    Praditpornsilp, K.
    Tungsanga, K.
    Eiam-Ong, S.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2007, 30 (12): : 1090 - 1097
  • [10] High-flux on-line hemodiafiltration with polyethersulfone membranes:: Performances in hemodiafiltration and impact of glucose administration
    Senécal, L
    Krieter, DH
    Moragues, HL
    Martin, K
    Canaud, B
    POLYETHERSULFONE: MEMBRANES FOR MULTIPLE CLINICAL APPLICATIONS, 2003, 138 : 88 - 98