Detector evaluation of a prototype amorphous selenium-based full field digital mammography system

被引:4
|
作者
Jesneck, JL [1 ]
Saunders, RS [1 ]
Samei, E [1 ]
Xia, JQ [1 ]
Lo, JY [1 ]
机构
[1] Duke Univ, Dept Radiol, Duke Adv Imaging Labs, Durham, NC 27710 USA
关键词
image quality; mammography; modulation transfer function; normalized noise power spectrum; detective quantum efficiency; digital imaging;
D O I
10.1117/12.596087
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study evaluated the physical performance of a selenium-based direct full-field digital mammography prototype detector (Siemens Mammomat Novation(DR)), including the pixel value vs. exposure linearity, the modulation transfer function (MTF), the normalized noise power spectrum (NNPS), and the detective quantum efficiency (DQE). The current detector is the same model which received an approvable letter from FDA for release to the US market. The results of the current prototype are compared to those of an earlier prototype. Two IEC standard beam qualities (RQA-M2: Mo/Mo, 28 kVp, 2 mm A1; RQA-M4: Mo/Mo, 35 kVp, 2 mm A1) and two additional beam qualities (MW2: W/Rh, 28 kVp, 2 mm A1; MW4: W/Rh, 35 kVp, 2 mm A1) were investigated. To calculate the modulation transfer function (MTF), a 0.1 mm Pt-Ir edge was imaged at each beam quality. Detector pixel values responded linearly against exposure values (R-2 0.999). As before, above 6 cycles/mm Mo/Mo MTF was slightly higher along the chest-nipple axis compared to the left-right axis. MTF was comparable to the previously reported prototype, with slightly reduced resolution. The DQE peaks ranged from 0.71 for 3.31 mu C/kg (12.83 mR) to 0.4 for 0.48 mu C/kg (1.86 mR) at 1.75 cycles/mm. for Mo/Mo at 28 kVp. The DQE range for W/Rh at 28 kVP was 0.81 at 2.03 mu C/kg (7.87 mR) to 0.50 at 0.50 mu C/kg (1.94 mR) at 1 cycle/mm. NNPS tended to increase with greater exposures, while all exposures had a significant low-frequency component. Bloom and detector edge artifacts observed previously were no longer present in this prototype. The new detector shows marked noise improvement, with slightly reduced resolution. There remain artifacts due to imperfect gain calibration, but at a reduced magnitude compared to a prototype detector.
引用
收藏
页码:478 / 485
页数:8
相关论文
共 50 条
  • [1] Physical characterization of a prototype selenium-based full field digital mammography detector
    Saunders, RS
    Samei, E
    Jesneck, JL
    Lo, JY
    MEDICAL PHYSICS, 2005, 32 (02) : 588 - 599
  • [2] Evaluation based on breast tomosynthesis of amorphous selenium full field digital mammography system
    Varjonen, M
    Strommer, P
    MEDICAL PHYSICS, 2005, 32 (06) : 1897 - 1897
  • [3] Evaluation of the imaging properties of an amorphous selenium-based flat panel detector for digital fluoroscopy
    Hunt, DC
    Tousignant, O
    Rowlands, JA
    MEDICAL PHYSICS, 2004, 31 (05) : 1166 - 1175
  • [4] Modulation transfer function of a selenium-based digital mammography system
    Hoheisel, M.
    Baetz, L.
    Mertelmeier, T.
    Giersch, J.
    Korn, A.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 1118 - 1122
  • [5] Modulation transfer function of a selenium-based digital mammography system
    Hoheisel, M
    Bätz, L
    Mertelmeier, T
    Giersch, J
    Korn, A
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3589 - 3593
  • [6] Relationships between detector design parameters and Imaging performance of amorphous selenium-based flat-panel detectors for digital mammography
    Zhao, W
    Ji, WG
    Rowlands, JA
    Debrie, A
    IWDM 2000: 5TH INTERNATIONAL WORKSHOP ON DIGITAL MAMMOGRAPHY, 2001, : 120 - 126
  • [7] Experimental investigation on the choice of the tungsten/rhodium anode/filter combination for an amorphous selenium-based digital mammography system
    Paula Toroi
    Federica Zanca
    Kenneth C. Young
    Chantal van Ongeval
    Guy Marchal
    Hilde Bosmans
    European Radiology, 2007, 17 : 2368 - 2375
  • [8] Experimental investigation on the choice of the tungsten/rhodium anode/filter combination for an amorphous selenium-based digital mammography system
    Toroi, Paula
    Zanca, Federica
    Young, Kenneth C.
    van Ongeval, Chantal
    Marchal, Guy
    Bosmans, Hilde
    EUROPEAN RADIOLOGY, 2007, 17 (09) : 2368 - 2375
  • [9] First results with real-time selenium-based full-field digital mammography three-dimensional imaging system
    Lehtimäki, M
    Pamilo, M
    Raulisto, L
    Kalke, M
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 922 - 929
  • [10] Radiographic techniques for digital mammography with an amorphous selenium detector
    Peck, D
    Flynn, M
    Dodge, C
    Swinford, A
    MEDICAL PHYSICS, 2003, 30 (06) : 1406 - 1406