Whole-Heart 4D Flow MRI for Evaluation of Normal and Regurgitant Valvular Flow: A Quantitative Comparison Between Pseudo-Spiral Sampling and EPI Readout

被引:6
|
作者
Blanken, Carmen P. S. [1 ]
Gottwald, Lukas M. [1 ]
Westenberg, Jos J. M. [2 ]
Peper, Eva S. [1 ]
Coolen, Bram F. [3 ]
Strijkers, Gustav J. [3 ]
Nederveen, Aart J. [1 ]
Planken, R. Nils [1 ]
Ooij, Pim [1 ]
机构
[1] Amsterdam UMC, Locat AMC, Dept Radiol & Nucl Med, Amsterdam, Netherlands
[2] Leiden UMC, Dept Radiol, Leiden, Netherlands
[3] Amsterdam UMC, Locat AMC, Dept Biomed Engn & Phys, Amsterdam, Netherlands
关键词
whole-heart 4D flow MRI; sparse sampling; compressed sensing reconstruction; EPI readout; valvular regurgitation; VALVE;
D O I
10.1002/jmri.27905
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Pseudo-spiral Cartesian sampling with compressed sensing reconstruction has facilitated highly accelerated 4D flow magnetic resonance imaging (MRI) in various cardiovascular structures. However, unlike echo planar imaging (EPI)-accelerated 4D flow MRI, it has not been validated in whole-heart applications. Hypothesis Pseudo-spiral 4D flow MRI (PROUD [PROspective Undersampling in multiple Dimensions]) is comparable to EPI in robustness of valvular flow measurements and remains comparable as the undersampling factor is increased and scan time reduced. Study Type Prospective. Population Twelve healthy subjects and eight patients with valvular regurgitation. Field Strength/Sequence 3.0 T; PROUD and EPI 4D flow sequences, 2D flow and balanced steady-state free precession sequences. Assessment Valvular blood flow was quantified using valve tracking. PROUD- and EPI-based measurements of aortic (AV) and pulmonary (PV) flow volumes and left and right ventricular stroke volumes were tested for agreement with 2D MRI-based measurements. PROUD reconstructions with undersampling factors (R) of 9, 14, 28, and 56 were tested for intervalve consistency (per valve, compared to the other valves) and preservation of peak velocities and E/A ratios. Statistical Tests We used repeated measures ANOVA, Bland-Altman, Wilcoxon signed rank, and intraclass correlation coefficients. P < 0.05 was considered statistically significant. Results PROUD and EPI intervalve consistencies were not significantly different both in healthy subjects (valve-averaged mean difference [limits of agreement width]: 3.2 +/- 0.8 [8.7 +/- 1.1] mL/beat for PROUD, 5.5 +/- 2.9 [13.7 +/- 2.3] mL/beat for EPI, P = 0.07) and in patients with valvular regurgitation (2.3 +/- 1.2 [15.3 +/- 5.9] mL/beat for PROUD, 0.6 +/- 0.6 [19.3 +/- 2.9] mL/beat for EPI, P = 0.47). Agreement between EPI and PROUD was higher than between 4D flow (EPI or PROUD) and 2D MRI for forward flow, stroke volumes, and regurgitant volumes. Up to R = 28 in healthy subjects and R = 14 in patients with valvular regurgitation, PROUD intervalve consistency remained comparable to that of EPI. Peak velocities and E/A ratios were preserved up to R = 9. Conclusion PROUD is comparable to EPI in terms of intervalve consistency and may be used with higher undersampling factors to shorten scan times further. Level of Evidence 1 Technical Efficacy Stage 2
引用
收藏
页码:1120 / 1130
页数:11
相关论文
共 41 条
  • [1] Editorial for "Whole-Heart 4D Flow MRI for Evaluation of Normal and Regurgitant Valvular Flow: A Quantitative Comparison Between Pseudo-Spiral Sampling and EPI Readout"
    Liu, Chia-Ying
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (04) : 1131 - 1132
  • [2] Retrospective Camera-Based Respiratory Gating in Clinical Whole-Heart 4D Flow MRI
    Gottwald, Lukas M.
    Blanken, Carmen P. S.
    Tourais, Joao
    Smink, Jouke
    Planken, R. Nils
    Boekholdt, S. Matthijs
    Meijboom, Lilian J.
    Coolen, Bram F.
    Strijkers, Gustav J.
    Nederveen, Aart J.
    van Ooij, Pim
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 54 (02) : 440 - 451
  • [3] Pseudo-spiral sampling and compressed sensing reconstruction provides flexibility of temporal resolution in accelerated aortic 4D flow MRI: A comparison with k-t principal component analysis
    Gottwald, Lukas M.
    Peper, Eva S.
    Zhang, Qinwei
    Coolen, Bram F.
    Strijkers, Gustav J.
    Nederveen, Aart J.
    van Ooij, Pim
    NMR IN BIOMEDICINE, 2020, 33 (04)
  • [4] Whole-heart 4D flow cardiac magnetic resonance in healthy dogs
    Pfammatter, N. S.
    Campagna, I. U.
    Toaldo, M. Baron
    Bruellmann, E.
    Richter, H.
    Kircher, P. R.
    Dennler, M.
    SCHWEIZER ARCHIV FUR TIERHEILKUNDE, 2018, 160 (05): : 295 - 303
  • [5] Prerequisites for Clinical Implementation of Whole-Heart 4D-Flow MRI: A Delphi Analysis
    van Schuppen, Joost
    van der Hulst, Annelies E.
    den Harder, J. Michiel
    Gottwald, Lukas M.
    van Luijk, Raschel D.
    van den Noort, Josien C.
    Nelissen, Jules L.
    Coerkamp, Casper F.
    Boekholdt, S. Matthijs
    Groot, Paul F. C.
    Nederveen, Aart
    van Ooij, Pim
    Planken, R. Nils
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2025, 61 (04) : 1618 - 1628
  • [6] Editorial for "Prerequisites for Clinical Implementation of Whole-Heart 4D-Flow MRI: A Delphi Analysis"
    Morales, Manuel A.
    Nezafat, Reza
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2025, 61 (04) : 1629 - 1630
  • [7] Highly accelerated 4D flow cardiovascular magnetic resonance using a pseudo-spiral Cartesian acquisition and compressed sensing reconstruction for carotid flow and wall shear stress
    Peper, Eva S.
    Gottwald, Lukas M.
    Zhang, Qinwei
    Coolen, Bram F.
    van Ooij, Pim
    Nederveen, Aart J.
    Strijkers, Gustav J.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [8] Highly accelerated 4D flow cardiovascular magnetic resonance using a pseudo-spiral Cartesian acquisition and compressed sensing reconstruction for carotid flow and wall shear stress
    Eva S. Peper
    Lukas M. Gottwald
    Qinwei Zhang
    Bram F. Coolen
    Pim van Ooij
    Aart J. Nederveen
    Gustav J. Strijkers
    Journal of Cardiovascular Magnetic Resonance, 22
  • [9] Quantitative evaluation of pulmonary hypertension using 4D flow MRI: A retrospective study
    Koike, Hirofumi
    Nishimura, Takamasa
    Morikawa, Minoru
    HELIYON, 2024, 10 (10)
  • [10] Whole-heart 4D flow can be acquired with preserved quality without respiratory gating facilitating clinical use
    Mikael Kanski
    Johannes Töger
    Katarina Steding-Ehrenborg
    Christos G Xanthis
    Karin Markenroth Bloch
    Einar Heiberg
    Marcus Carlsson
    Håkan Arheden
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)