Scleral contact lens thickness profiles: The relationship between average and centre lens thickness

被引:27
|
作者
Vincent, Stephen J. [1 ]
Alonso-Caneiro, David [1 ]
Kricancic, Henry [1 ]
Collins, Michael J. [1 ]
机构
[1] Queensland Univ Technol, Sch Optometry & Vis Sci, Contact Lens & Visual Opt Lab, Room D513,O Block,Victoria Pk Rd, Brisbane, Qld 4059, Australia
来源
CONTACT LENS & ANTERIOR EYE | 2019年 / 42卷 / 01期
关键词
Scleral contact lens; Scleral lens thickness; OCT imaging; Oxygen transmissibility; TRANSMISSIBILITY;
D O I
10.1016/j.clae.2018.03.002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To develop a methodology to reliably determine the thickness profile of scleral contact lenses and examine the relationship between the centre and average lens thickness for a range of lens designs and back vertex powers. Methods: High-resolution images of 37 scleral trial lenses (Epicon LC, Rose K2 XL and ICD 16.5) were captured using an optical coherence tomographer, and their thickness profiles were generated after correcting for known measurement artefacts. Centre lens thickness values were compared with manual lens gauge measurements, and repeatability was assessed by comparing average thickness values derived from orthogonal meridians of each lens. Results: The imaging technique displayed a high level of agreement with a manual lens gauge for centre thickness measurements; mean difference 5 +/- 9 mu m (95% LoA -14 to + 23 mu m), and a very high level of repeatability; mean difference between orthogonal meridians 1 +/- 3 mu m (95% LoA -6 to +8 mu m). Lens thick-ness profiles varied between lens designs, with distance from the lens centre, and with back vertex power. Increasing back vertex powers resulted in a significant over or underestimation (up to 33% for high minus powers) of the average lens thickness based on the centre lens thickness. Conclusions: The thickness of scleral contact lenses varies with distance from the lens centre and the back vertex power. The average lens thickness value derived from the entire lens provides a more appropriate representation of the true lens thickness and should be used in the calculation of scleral lens oxygen transmissibility.
引用
收藏
页码:55 / 62
页数:8
相关论文
共 50 条
  • [1] DETERMINATION OF THE AVERAGE THICKNESS OF A CONTACT-LENS
    DEDONATO, LM
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1981, 58 (10): : 846 - 847
  • [2] Scleral lens centration: The in fl uence of centre thickness, scleral topography, and apical clearance
    Kowalski, Louise P.
    Collins, Michael J.
    Vincent, Stephen J.
    CONTACT LENS & ANTERIOR EYE, 2020, 43 (06): : 562 - 567
  • [3] Scleral Contact Lens Effects on Central and Peripheral Corneal Thickness.
    Miller, William Leonard
    Vance, Kelsea
    Johnson, Leah
    Bergmanson, Jan P. G.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [4] EFFECTS OF CONTACT LENS THICKNESS
    WILLIAMS, CE
    AMERICAN JOURNAL OF OPTOMETRY AND ARCHIVES OF AMERICAN ACADEMY OF OPTOMETRY, 1967, 44 (09): : 591 - &
  • [5] APPLICATION OF HYDROGEL LENS AVERAGE THICKNESS
    BRENNAN, NA
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1984, 61 (10): : 636 - 642
  • [6] Central and Peripheral Corneal Thickness Changes during Scleral Contact Lens Wear
    Tse, Vivien
    Kim, Young Hyun
    Lin, Kristina
    Tan, Bo
    Zhou, Yixiu
    Li, Wing
    Lin, Meng C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [7] A CONTACT LENS FOR ESTIMATING CORNEAL THICKNESS
    FRIEDMAN, B
    EYE EAR NOSE AND THROAT MONTHLY, 1967, 46 (03): : 344 - &
  • [8] Changes in the corneal thickness and limbus after 1 year of scleral contact lens use
    de Luis Eguileor, Beatriz
    Acera, Arantxa
    Santamaria Carro, Alaitz
    Feijoo Lera, Raquel
    Escudero Argaluza, Julene
    Etxebarria Ecenarro, Jaime
    EYE, 2020, 34 (09) : 1654 - 1661
  • [9] Changes in the corneal thickness and limbus after 1 year of scleral contact lens use
    Beatriz de Luis Eguileor
    Arantxa Acera
    Alaitz Santamaría Carro
    Raquel Feijoo Lera
    Julene Escudero Argaluza
    Jaime Etxebarria Ecenarro
    Eye, 2020, 34 : 1654 - 1661
  • [10] The impact of hydrogel lens settling on the thickness of the tears and contact lens
    Nichols, JJ
    King-Smith, PE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (08) : 2549 - 2554