Accessing depth-resolved high spatial frequency content from the optical coherence tomography signal

被引:7
|
作者
Alexandrov, Sergey [1 ]
Arangath, Anand [1 ]
Zhou, Yi [1 ]
Murphy, Mary [2 ]
Duffy, Niamh [2 ]
Neuhaus, Kai [1 ]
Shaw, Georgina [2 ]
McAuley, Ryan [1 ]
Leahy, Martin [1 ,3 ]
机构
[1] Natl Univ Ireland, Natl Biophoton & Imaging Platform, Sch Phys, Tissue Opt & Microcirculat Imaging Grp, Galway H91 TK33, Ireland
[2] Natl Univ Ireland, Sch Med, Regenerat Med Inst, Galway, Ireland
[3] Inst Photon Sci ICFO, Barcelona, Spain
基金
欧盟地平线“2020”;
关键词
MESENCHYMAL STEM-CELLS; CHONDROGENIC DIFFERENTIATION; OCT;
D O I
10.1038/s41598-021-96619-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Optical coherence tomography (OCT) is a rapidly evolving technology with a broad range of applications, including biomedical imaging and diagnosis. Conventional intensity-based OCT provides depth-resolved imaging with a typical resolution and sensitivity to structural alterations of about 5-10 microns. It would be desirable for functional biological imaging to detect smaller features in tissues due to the nature of pathological processes. In this article, we perform the analysis of the spatial frequency content of the OCT signal based on scattering theory. We demonstrate that the OCT signal, even at limited spectral bandwidth, contains information about high spatial frequencies present in the object which relates to the small, sub-wavelength size structures. Experimental single frame imaging of phantoms with well-known sub-micron internal structures confirms the theory. Examples of visualization of the nanoscale structural changes within mesenchymal stem cells (MSC), which are invisible using conventional OCT, are also shown. Presented results provide a theoretical and experimental basis for the extraction of high spatial frequency information to substantially improve the sensitivity of OCT to structural alterations at clinically relevant depths.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Accessing depth-resolved high spatial frequency content from the optical coherence tomography signal
    Sergey Alexandrov
    Anand Arangath
    Yi Zhou
    Mary Murphy
    Niamh Duffy
    Kai Neuhaus
    Georgina Shaw
    Ryan McAuley
    Martin Leahy
    Scientific Reports, 11
  • [2] Depth-resolved microscopy of cortical hemodynamics with optical coherence tomography
    Srinivasan, Vivek J.
    Sakadzic, Sava
    Gorczynska, Iwona
    Ruvinskaya, Svetlana
    Wu, Weicheng
    Fujimoto, James G.
    Boas, David A.
    OPTICS LETTERS, 2009, 34 (20) : 3086 - 3088
  • [3] Robust, accurate depth-resolved attenuation characterization in optical coherence tomography
    Li, Kaiyan
    Liang, Wenxuan
    Yang, Zihan
    Liang, Yanmei
    Wan, Suiren
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (02): : 672 - 687
  • [4] Automated, Depth-Resolved Estimation of the Attenuation Coefficient From Optical Coherence Tomography Data
    Smith, Gennifer T.
    Dwork, Nicholas
    O'Connor, Daniel
    Sikora, Uzair
    Lurie, Kristen L.
    Pauly, John M.
    Ellerbee, Audrey K.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (12) : 2592 - 2602
  • [5] Depth-resolved attenuation coefficient estimation from optical coherence tomography data in case of incomplete signal attenuation in the imaging depth range
    Moiseev, Alexander
    Potapov, Arseniy
    Sherstnev, Evgeny
    Gelikonov, Grigory
    Gelikonov, Valentin
    Sirotkina, Marina
    Shilyagin, Pavel
    Ksenofontov, Sergey
    Gladkova, Natalia
    LASER PHYSICS LETTERS, 2023, 20 (07)
  • [6] High resolution coherence domain depth-resolved nailfold capillaroscopy based on correlation mapping optical coherence tomography
    Subhash, Hrebesh M.
    O'Gorman, Sean
    Neuhaus, Kai
    Leahy, Martin
    OPTICAL DIAGNOSTICS AND SENSING XIV: TOWARD POINT-OF-CARE DIAGNOSTICS, 2014, 8951
  • [7] Depth-resolved measurement of optical radiation-pressure forces with optical coherence tomography
    Leartprapun, Nichaluk
    Iyer, Rishyashring R.
    Adie, Steven G.
    OPTICS EXPRESS, 2018, 26 (03): : 2410 - 2426
  • [8] General model for depth-resolved estimation of the optical attenuation coefficients in optical coherence tomography
    Amaral, Marcello M.
    Zezell, Denise M.
    Monte, Adamo F. G.
    de Cara, Ana C. B.
    Araujo, Jeann C. R.
    Antunes, Andrea
    Freitas, Anderson Z.
    JOURNAL OF BIOPHOTONICS, 2019, 12 (10)
  • [9] Depth-resolved monitoring of glucose diffusion in tissues by using optical coherence tomography
    Ghosn, Mohamad G.
    Tuchin, Valery V.
    Larin, Kirill V.
    OPTICS LETTERS, 2006, 31 (15) : 2314 - 2316
  • [10] Depth-resolved imaging of colon tumor using optical coherence tomography and fluorescence laminar optical tomography
    Tang, Qinggong
    Wang, Jianting
    Frank, Aaron
    Lin, Jonathan
    Li, Zhifang
    Chen, Chao-Wei
    Jin, Lily
    Wu, Tongtong
    Greenwald, Bruce D.
    Mashimo, Hiroshi
    Chen, Yu
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (12): : 5218 - 5232