Simultaneous analysis of organochlorinated pesticides (OCPs) and polychlorinated biphenyls (PCBs) from marine samples using automated pressurized liquid extraction (PLE) and Power Prep™ clean-up

被引:25
|
作者
Helaleh, Murad I. H. [1 ]
Al-Rashdan, Amal [1 ]
Ibtisam, A. [1 ]
机构
[1] Kuwait Inst Sci Res, Cent Analyt Lab, Chromatog Sect, Safat 13109, Kuwait
关键词
Fast analysis; Marine sample; Clean-up system; OCPs and PCBs; ACCELERATED SOLVENT-EXTRACTION; POLYCYCLIC AROMATIC-HYDROCARBONS; PERSISTENT ORGANIC POLLUTANTS; DIBENZO-P-DIOXINS; FISH; RESIDUES; BIOACCUMULATION; CALIFORNIA; PBDES;
D O I
10.1016/j.talanta.2012.02.031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated pressurized liquid extraction (PLE) method followed by Power Prep (TM) clean-up was developed for organochlorinated pesticide (OCP) and polychlorinated biphenyl (PCB) analysis in environmental marine samples of fish, squid, bivalves, shells, octopus and shrimp. OCPs and PCBs were simultaneously determined in a single chromatographic run using gas chromatography-mass spectrometry-negative chemical ionization (GC-MS-NCI). About 5 g of each biological marine sample was mixed with anhydrous sodium sulphate and placed in the extraction cell of the PLE system. PLE is controlled by means of a PC using DMS 6000 software. Purification of the extract was accomplished using automated Power Prep (TM) clean-up with a pre-packed disposable silica column (6 g) supplied by Fluid Management Systems (FMS). All OCPs and PCBs were eluted from the silica column using two types of solvent: 80 mL of hexane and a 50 mL mixture of hexane and dichloromethane (1:1). A wide variety of fish and shellfish were collected from the fish market and analyzed using this method. The total PCB concentrations were 2.53, 0.25, 0.24, 0.24, 0.17 and 1.38 ng g(-1) (w/w) for fish, squid, bivalves, shells, octopus and shrimp, respectively, and the corresponding total OCP concentrations were 30.47, 2.86, 0.92, 10.72, 5.13 and 18.39 ng g(-1) (w/w). Lipids were removed using an SX-3 Bio-Beads gel permeation chromatography (GPC) column. Analytical criteria such as recovery, reproducibility and repeatability were evaluated through a range of biological matrices. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:44 / 49
页数:6
相关论文
共 30 条
  • [1] Automated pressurized liquid extraction (PLE) and automated power-prep™ clean-up for the analysis of polycyclic aromatic hydrocarbons, organo-chlorinated pesticides and polychlorinated biphenyls in marine samples
    Helaleh, Murad I. H.
    Al-Rashdan, Amal
    ANALYTICAL METHODS, 2013, 5 (06) : 1617 - 1622
  • [2] Simultaneous extraction and clean-up of polychlorinated biphenyls and their metabolites from small tissue samples using pressurized liquid extraction
    Kania-Korwel, Izabela
    Zhao, Hongxia
    Norstrom, Karin
    Li, Xueshu
    Hornbuckle, Keri C.
    Lehmler, Hans-Joachim
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1214 (1-2) : 37 - 46
  • [3] Determination of polychlorinated biphenyls in biota samples using simultaneous pressurized liquid extraction and purification
    Gómez-Ariza, JL
    Bujalance, M
    Giráldez, I
    Velasco, A
    Morales, E
    JOURNAL OF CHROMATOGRAPHY A, 2002, 946 (1-2) : 209 - 219
  • [4] Simultaneous pressurized liquid extraction and clean-up for the analysis of polybrominated biphenyls by gas chromatography-tandem mass spectrometry
    Malavia, J.
    Santos, F. J.
    Galceran, M. T.
    TALANTA, 2011, 84 (04) : 1155 - 1162
  • [5] Simultaneous extraction and clean-up of polybrominated diphenyl ethers and polychlorinated biphenyls from sheep liver tissue by selective pressurized liquid extraction and analysis by gas chromatography-mass spectrometry
    Zhang, Zulin
    Ohiozebau, Ehimai
    Rhind, Stewart M.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (08) : 1203 - 1209
  • [6] Modular pressurized liquid extraction for simultaneous extraction, clean-up and fractionation of PCDD/Fs in soil, sediment and sludge samples
    Do, Lan
    Xuan, Thong H.
    Lundstedt, Staffan
    Haglund, Peter
    ANALYTICAL METHODS, 2013, 5 (05) : 1231 - 1237
  • [7] Fast automated extraction and clean-up of biological fluids for polychlorinated dibenzo-p-dioxins, dibenzofurans and coplanar polychlorinated biphenyls analysis
    Focant, JF
    De Pauw, E
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 776 (02): : 199 - 212
  • [8] Pesticides in seaweed: optimization of pressurized liquid extraction and in-cell clean-up and analysis by liquid chromatography–mass spectrometry
    R. A. Lorenzo
    S. Pais
    I. Racamonde
    D. García-Rodríguez
    A. M. Carro
    Analytical and Bioanalytical Chemistry, 2012, 404 : 173 - 181
  • [9] New strategies for extraction and clean-up of persistent organic pollutants from food and feed samples using selective pressurized liquid extraction
    Björklund, E
    Sporring, S
    Wiberg, K
    Haglund, P
    von Hillist, C
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (04) : 318 - 325
  • [10] Pesticides in seaweed: optimization of pressurized liquid extraction and in-cell clean-up and analysis by liquid chromatography-mass spectrometry
    Lorenzo, R. A.
    Pais, S.
    Racamonde, I.
    Garcia-Rodriguez, D.
    Carro, A. M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (01) : 173 - 181