Simple and sensitive determination of radium-226 in river water by single column-chromatographic separation coupled to SF-ICP-MS analysis in medium resolution mode

被引:9
|
作者
Yang, Guosheng [1 ]
Zheng, Jian [1 ,2 ]
Tagami, Keiko [1 ,2 ]
Uchida, Shigeo [2 ]
Zhang, Jing [3 ]
Wang, Jinlong [4 ]
Du, Jinzhou [4 ]
机构
[1] Natl Inst Quantum & Radiol Sci & Technol, Ctr Adv Radiat Emergency Med, Inage Ku, 4-9-1 Anagawa, Chiba 2638555, Japan
[2] Natl Inst Quantum & Radiol Sci & Technol, Natl Inst Radiol Sci, Biospher Assessment Waste Disposal Team, Inage Ku, 4-9-1 Anagawa, Chiba 2638555, Japan
[3] Univ Toyama, Grad Sch Sci & Engn, Gofuku 3190, Toyama 9308555, Japan
[4] East China Normal Univ, Stake Key Lab Estuarine & Coastal Res, Shanghai 200241, Peoples R China
关键词
Radium-226; SF-ICP-MS; River water; Small volume sample; Single chromatographic column separation; PLASMA-MASS SPECTROMETRY; ENVIRONMENTAL-SAMPLES; RADIUM-ISOTOPES; HEAVY-METALS; PU ISOTOPES; EXTRACTION; PRECONCENTRATION; QUANTIFICATION; RADIOACTIVITY; RADIONUCLIDES;
D O I
10.1016/j.jenvrad.2020.106305
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This article describes a novel and simple method to measure ultra-trace Ra-226 in river water samples at fg L-1 (mBq L-1) levels as a means for surveying Ra-226 in an unintended contamination in river water. To simplify the procedure, a single column was used for separation and purification; 10 mL of AG 50W-X8 resin was packed into a 10 mL Eppendorf pipette tip, which was used as a separation column. A 500 mL sample solution was loaded, and interfering elements were removed with 80 mL 4 M HCl in 20% ethanol. Subsequently, Ra together with Ba was eluted by 20 mL 5 M HNO3 prior to SF-ICP-MS analysis; this allows the naturally existing Ba in water samples to be employed as a yield tracer for Ra-226 analysis. Using the medium mode of SF-ICP-MS, the instrumental detection limit of 380 fg L-1 (10 mBq L-1) was obtained. An extremely low method detection limit of 0.46 fg L-1 (0.02 mBq L-1) was achieved with 500-fold pre-concentration. Finally, the developed technique was applied to analyze natural water samples collected from Japanese rivers, in which the Ra-226 concentrations varied in the range of 0.7-49.6 fg L-1 (0.03-1.82 mBq L-1).
引用
收藏
页数:8
相关论文
共 2 条
  • [1] Comparison of radium-226 separation methods based on chromatographic and extraction resins for its determination by ICP-MS in drinking waters
    Roulier, Marine
    Baya, Pascale Anabelle
    Roberge, Steeve
    Lariviere, Dominic
    JOURNAL OF MASS SPECTROMETRY, 2024, 59 (02):
  • [2] Simultaneous determination of ultra-trace level 237Np and Pu isotopes in soil and sediment samples by SF-ICP-MS with a single column chromatographic separation
    Huang, Zhaoya
    Ni, Youyi
    Wang, Hai
    Zheng, Jian
    Yamazaki, Shinnosuke
    Sakaguchi, Aya
    Long, Xinggui
    Uchida, Shigeo
    MICROCHEMICAL JOURNAL, 2019, 148 : 597 - 604