Evaluation of Efficiency of Polymerization, Surface Roughness, Porosity and Adaptation of Flowable and Sculptable Bulk Fill Composite Resins

被引:7
|
作者
Gjorgievska, Elizabeta [1 ,2 ]
Oh, Daniel S. [2 ]
Haam, Daewon [2 ]
Gabric, Dragana [3 ]
Coleman, Nichola J. [4 ]
机构
[1] Univ Ss Cyril & Methodius, Fac Dent Med, Dept Paediat & Prevent Dent, Skopje 1000, North Macedonia
[2] Columbia Univ, Coll Dent Med, New York, NY 10032 USA
[3] Univ Zagreb, Clin Hosp Ctr, Sch Dent Med, Dept Oral Surg, Zagreb 10000, Croatia
[4] Univ Greenwich, Fac Engn & Sci, Chatham ME4 4TB, Kent, England
来源
MOLECULES | 2021年 / 26卷 / 17期
关键词
composite resin; bulk fill; polymerization; surface roughness; porosity; adaptation; VOIDS; CURE; CONVERSION; SHRINKAGE; DEPTH;
D O I
10.3390/molecules26175202
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A new category of commercial bulk fill composite resins (CRs) enables the placement of 4-mm-thick layers as an alternative to the traditional time-consuming incremental technique. The purpose of the present study was to compare the efficiency of the polymerization, adaptation and porosity of two high-viscosity 'sculptable' bulk fill CRs (Filtek (TM) Bulk Fill (3M (TM) ESPE, St. Paul, MN, USA) and Tetric EvoCeram(R) Bulk Fill (Ivoclar Vivadent AG, Schwan, Liechtenstein)) and two low-viscosity 'flowable' bulk fill CRs (SureFil(R) SDR (TM) flow (Dentsply Sirona, Charlotte, NC, USA) and Tetric EvoFlow(R) Bulk Fill (Ivoclar Vivadent AG, Schaan, Liechtenstein)). Cylindrical samples of the bulk fill CRs (4 mm height x 10 mm diameter) were analyzed by Fourier-transform infrared spectroscopy (FTIR) and atomic force microscopy (AFM). Additionally, occlusal cavities were prepared in twelve extracted human molars and restored with the bulk fill CRs (n = 3 for each CR). The adaptation and porosity of the bulk fill CRs were evaluated by X-ray microcomputed tomography (mu CT) with a 3D morphometric analysis, and the adaptation was also analyzed by scanning electron microscopy (SEM) on longitudinal vestibulo-oral sections of the restored teeth. The AFM analysis demonstrated that the surface roughness of the SureFil(R) SDR (TM) flow was higher than that of the Tetric EvoFlow(R) Bulk Fill and that the surface roughness of Filtek (TM) Bulk Fill was higher than that of Tetric EvoCeram(R) Bulk Fill. mu CT and SEM confirmed that the flowable bulk fill CRs had excellent adaptation to the cavity walls. The 3D morphometric analysis showed the highest and lowest degrees of porosity in Filtek (TM) Bulk Fill and Tetric EvoFlow(R) Bulk Fill, respectively. In general, the flowable bulk fill CRs exhibited better adaptation, a higher efficiency of polymerization and lower porosity than the sculptable materials.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Polymerization Shrinkage and Depth of Cure of Bulk Fill Flowable Composite Resins
    Garcia, D.
    Yaman, P.
    Dennison, J.
    Neiva, G. F.
    OPERATIVE DENTISTRY, 2014, 39 (04) : 441 - 448
  • [2] Efficiency of polymerization of bulk-fill composite resins: a systematic review
    Reis, Andre Figueiredo
    Vestphal, Mariana
    do Amaral, Roberto Cesar
    Rodrigues, Jose Augusto
    Roulet, Jean-Francois
    Roscoe, Marina Guimaraes
    BRAZILIAN ORAL RESEARCH, 2017, 31 : 37 - 48
  • [3] Surface roughness evaluation of flowable composite resins before and after brushing
    Mendonça, C
    Ramos, J
    Vieira, M
    Guerra, F
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A339 - A339
  • [4] Evaluation of Water Sorption-solubility and Surface Roughness of Different Bulk Fill Composite Resins
    Gonulol, Nihan
    Sen Tunc, Emine
    Ozer, Sezin
    Yildizli, Kemal
    MEANDROS MEDICAL AND DENTAL JOURNAL, 2019, 20 (01): : 28 - 33
  • [5] Polymerization Stress and Gap Formation of Self-adhesive, Bulk-fill and Flowable Composite Resins
    Nakano, E. L.
    de Souza, A. S. C.
    Boaro, L. C. C.
    Catalani, L. H.
    Braga, R. R.
    Goncalves, F.
    OPERATIVE DENTISTRY, 2020, 45 (06) : E308 - E316
  • [6] Comparative analysis of effect of fruit juices on surface roughness of bulk fill and flowable composite material
    Kallivayalil, Joseph George
    Ganesh, S. Balaji
    Jayalakshmi, S.
    JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2022, 13 : S136 - S139
  • [7] Evaluation of the Surface Roughness of Bulk-Fill Composite Resins after Submission to Acidic and Abrasive Aggressions
    Taraboanta, Ionut
    Buhatel, Dan
    Concita, Corina Alexandra Brinza
    Andrian, Sorin
    Nica, Irina
    Taraboanta-Gamen, Andra Claudia
    Branzan, Razvan
    Stoleriu, Simona
    BIOMEDICINES, 2022, 10 (05)
  • [8] Polymerization stress evolution of a bulk-fill flowable composite under different compliances
    Guo, Yongwen
    Landis, Forrest A.
    Wang, Zhengzhi
    Bai, Ding
    Jiang, Li
    Chiang, Martin Y. M.
    DENTAL MATERIALS, 2016, 32 (04) : 578 - 586
  • [9] Surface properties and bacterial adhesion of bulk -fill composite resins
    Bilgili, Dilber
    Dundar, Ayse
    Barutcugil, Cagatay
    Tayfun, Deniz
    Ozyurt, Ozlem Koyuncu
    JOURNAL OF DENTISTRY, 2020, 95
  • [10] Roughness profile and surface roughness after toothbrushing and degree of conversion of bulk-fill resins
    Terada, Raquel Sano Suga
    Fronza, Bruna Marin
    Faraoni, Juliana Jendiroba
    Hoshino, Lidiane Vizioli de Castro
    Sato, Francielle
    Palma-dibb, Regina Guenka
    Scheffel, Debora Lopes Salles
    Giannini, Marcelo
    BRAZILIAN ORAL RESEARCH, 2024, 38 : 1 - 12