Performance of an adiabatic cross-flow liquid-desiccant absorber inside a refrigerated warehouse

被引:10
|
作者
Pineda, Sergio M. [1 ]
Diaz, Gerardo [1 ]
机构
[1] Univ Calif Merced, Sch Engn, Merced, CA 95343 USA
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2011年 / 34卷 / 01期
关键词
Cold storage; Desiccant; Defrosting; Energy consumption; Reduction; Moisture; SYSTEM; AIR; DEHUMIDIFICATION;
D O I
10.1016/j.ijrefrig.2010.08.005
中图分类号
O414.1 [热力学];
学科分类号
摘要
Liquid-desiccant systems have been extensively studied as a way of reducing the latent load on air conditioning systems. Most of the studies have targeted the removal of moisture from air at ambient conditions. The literature about the use of liquid desiccants in low temperature applications is scarce. In this study, a small-scale liquid-desiccant absorber is installed inside a commercial refrigerated warehouse. Its performance under realistic operating conditions inside a pre-cooling room is analyzed. The results show that the dew point temperature of the air downstream of the absorber is comparable to the evaporator surface temperature suggesting the potential to delay the formation of ice on the cooling coil. An internal heat exchanger is used to lower the temperature of the inlet liquid-desiccant flow to the absorber and the regeneration process is performed using only ambient air. The analysis of the reduction in water and energy consumption for a scaled-up system is also performed. (C) 2010 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:138 / 147
页数:10
相关论文
共 50 条
  • [1] Analysis of a cross-flow liquid-desiccant falling-film
    Emhofer, J.
    Beladi, B.
    Dudzinski, P.
    Fleck, T.
    Kuhlmann, H. C.
    APPLIED THERMAL ENGINEERING, 2017, 124 : 91 - 102
  • [2] ANALYSIS OF HEAT AND MASS TRANSFER OF AN ADIABATIC CROSS-FLOW LIQUID DESICCANT ABSORBER OPERATING AT LOW TEMPERATURES
    Pineda, Sergio M.
    Diaz, Gerardo
    HT2009: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE 2009, VOL 1, 2009, : 647 - 655
  • [3] Performance Analysis and Limiting Parameters of Cross-flow Membrane-based Liquid-desiccant Air Dehumidifiers
    Ahmadi, Behnam
    Ahmadi, Masoud
    Nawaz, Kashif
    Momen, Ayyoub M.
    Bigham, Sajjad
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 132 : 21 - 29
  • [4] Performance characteristics of cross-flow membrane contactors for liquid desiccant systems
    Das, Rajat Subhra
    Jain, Sanjeev
    APPLIED ENERGY, 2015, 141 : 1 - 11
  • [5] Numerical study on dehumidification performance of a cross-flow liquid desiccant air dehumidifier
    Lu, Jun
    Wang, Meilin
    Li, Yongcai
    Yang, Lulu
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3630 - 3637
  • [6] Experimental analysis of dehumidification performance of counter and cross-flow liquid desiccant dehumidifiers
    Cho, Hye-Jin
    Cheon, Seong-Yong
    Jeong, Jae-Weon
    APPLIED THERMAL ENGINEERING, 2019, 150 : 210 - 223
  • [7] Numerical investigation of transient heat and mass transfer in a parallel-flow liquid-desiccant absorber
    Diaz, Gerardo
    HEAT AND MASS TRANSFER, 2010, 46 (11-12) : 1335 - 1344
  • [8] Numerical investigation of transient heat and mass transfer in a parallel-flow liquid-desiccant absorber
    Gerardo Diaz
    Heat and Mass Transfer, 2010, 46 : 1335 - 1344
  • [9] New mass transfer performance data of a cross-flow liquid desiccant dehumidification system
    Moon, C. G.
    Bansal, P. K.
    Jain, Sanjeev
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (03): : 524 - 533
  • [10] Performance testing of a cross-flow membrane-based liquid desiccant dehumidification system
    Bai, Hongyu
    Zhu, Jie
    Chen, Ziwei
    Ma, Lina
    Wang, Ruzhu
    Li, Tingxian
    APPLIED THERMAL ENGINEERING, 2017, 119 : 119 - 131