Use of the diabetes risk score for opportunistic screening of undiagnosed diabetes and impaired glucose tolerance - The IGLOO (Impaired Glucose Tolerance and Long-Term Outcomes Observational) study

被引:125
|
作者
Franciosi, M [1 ]
De Berardis, G [1 ]
Rossi, MCE [1 ]
Sacco, M [1 ]
Belfiglio, M [1 ]
Pellegrini, F [1 ]
Tognoni, G [1 ]
Valentini, M [1 ]
Nicolucci, A [1 ]
机构
[1] Ist Ric Farmacol Mario Negri, Consorzio Mario Negri Sud, Dept Clin Pharmacol & Epidemiol, I-66030 Santa Maria Imbaro, CH, Italy
关键词
D O I
10.2337/diacare.28.5.1187
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE- To evaluate all opportunistic screening strategy addressed to Individuals with one or more cardiovascular risk factor, based on the Diabetes Risk Score (DRS) as the initial instrument, for the identification of individuals with type 2 diabetes or Impaired glucose tolerance (IGT). RESEARCH DESIGN AND METHODS - The DRS, a simple self-administered questionnaire, was completed by individuals identified by general practitioners and presenting with one or more cardiovascular risk factor. All patients underwent a 2-h oral glucose tolerance test (OGTT). The optimal DRS cutoff was calculated by applying the receiver-operating characteristic curve. RESULTS - Qverall, 1.377 individuals aged between 55 and 75 years received an OGTT and completed the DRS. Mean DRS values showed a marked variation according to glucose metabolism categories, as follows: 8.7 +/- 3.0 in nomioglycemic individuals, 9.5 +/- 3.1 in individuals with Impaired Fasting glucose. 9.9 +/- 3.3 in Individuals with IGT, and 12.0 +/- 3.5 in individuals with type 2 diabetes. The receiver-operating characteristic curve showed that, With a cutoff of 9, the sensitivity of DRS in detecting individuals With glucose abnormalities (type 2 diabetes or IGT) was 77% and the specificity 45%. The use of the DRS as all initial Screening instrument, followed by the measurement of fasting blood glucose in individuals wit h a score >= 9 and by the OGTT Individuals with a fasting blood glucose between 5.6 and 6.9 mmol/l, would lead to the identification of 83% of the case subjects with type 2 diabetes and 57% of the case subjects with IGT, at a cost of an OGTT in 38% of the sample and,I fasting blood glucose in 64%. CONCLUSIONS - The DRS can represent a valid inexpensive instrument for opportunistic screening and a useful alternative to indiscriminate Fasting blood glucose measurement, not readily available in general practice.
引用
收藏
页码:1187 / 1194
页数:8
相关论文
共 50 条
  • [1] Undiagnosed diabetes or impaired glucose tolerance and cardiovascular risk
    Eastman, RC
    Cowie, CC
    Harris, MI
    DIABETES CARE, 1997, 20 (02) : 127 - 128
  • [2] A Chinese diabetes risk score for opportunistic screening of undiagnosed diabetes and abnormal glucose tolerance
    Liu, M.
    Jin, M.
    Pan, C.
    DIABETOLOGIA, 2010, 53 : S155 - S155
  • [3] Evaluation of the Finnish Diabetes Risk Score as a screening tool for impaired fasting glucose, impaired glucose tolerance and undetected diabetes
    Tankova, Tsvetalina
    Chakarova, Nevena
    Atanassova, Iliana
    Dakovska, Lilia
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2011, 92 (01) : 46 - 52
  • [4] A Chinese Diabetes Risk Score for Screening of Undiagnosed Diabetes and Abnormal Glucose Tolerance
    Liu, Min
    Pan, Changyu
    Jin, Mengmeng
    DIABETES TECHNOLOGY & THERAPEUTICS, 2011, 13 (05) : 501 - 507
  • [5] Impaired glucose tolerance and unidentified diabetes
    Heine, RJ
    Mooy, JM
    POSTGRADUATE MEDICAL JOURNAL, 1996, 72 (844) : 67 - 71
  • [6] IMPAIRED GLUCOSE-TOLERANCE AND DIABETES
    DRURY, MI
    BRITISH MEDICAL JOURNAL, 1981, 282 (6258): : 153 - 153
  • [7] A Colombian diabetes risk score for detecting undiagnosed diabetes and impaired glucose regulation
    Barengo, Noel Christopher
    Tamayo, Diana Carolina
    Tono, Teresa
    Tuomilehto, Jaakko
    PRIMARY CARE DIABETES, 2017, 11 (01) : 86 - 93
  • [8] Progression of normal glucose tolerance to impaired glucose tolerance or diabetes in the elderly
    Hiltunen, L
    Kivela, SL
    Laara, E
    KeinanenKiukaanniemi, S
    DIABETES RESEARCH AND CLINICAL PRACTICE, 1997, 35 (2-3) : 99 - 106
  • [9] EZSCAN SCREENING OF IMPAIRED GLUCOSE TOLERANCE AND DIABETES IN A CHINESE POPULATION
    Chen, Lizhu
    Hu, Dayi
    HEART, 2012, 98 : E154 - E154
  • [10] Fasting plasma glucose and glycated haemoglobin in the screening of diabetes and impaired glucose tolerance
    Mannucci, E
    Ognibene, A
    Sposato, I
    Brogi, M
    Gallori, G
    Bardini, G
    Cremasco, F
    Messeri, G
    Rotella, CM
    ACTA DIABETOLOGICA, 2003, 40 (04) : 181 - 186