Comparison of corneal thickness measurements by ultrasound and scheimpflug photography in eyes that have undergone laser in situ keratomileusis

被引:62
|
作者
Ciolino, Joseph B. [1 ]
Khachikian, Steven S. [1 ]
Belin, Michael W. [1 ,2 ]
机构
[1] Albany Med Coll, Dept Ophthalmol, Albany, NY 12208 USA
[2] Cornea Consultants Albany, Slingerlands, NY USA
关键词
D O I
10.1016/j.ajo.2007.08.026
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare two methods of measuring central cornea thickness (CCT) in eyes that have under, gone laser in situ keratomileusis (LASIK). DESIGN: Prospective clinical trial. METHODS: The corneal thickness from 104 eyes of 53 consecutive patients undergoing the one-year follow,up after LASIK was measured with both the Pentacam (Oculus, Inc, Wetzlar, Germany) and ultrasonic pachymetry. All patients were examined at one clinical setting, where first Pentacam imaging was performed by one technician and then ultrasound pachymetry was performed by a masked second technician. The results were compared. RESULTS: The average age of the patient population was 38 years (range, 22 to 56 years) of those who underwent the one year follow,up examination an aver, age of 406 days (range, 264 to 579 days) after LASIK. The mean CCT measurement was 506 +/- 29.5 mu m (range, 454 to 574 mu m) with the Pentacam topographer and 505 +/- 31.7 mu m (range, 433 to 576 mu m) with ultrasound pachymetry. The average difference (Pentacam minus ultrasound) was 1.4 +/- 10.4 mu m (range, -21.8 to 23.4 mu m). CONCLUSIONS: The Pentacam's CCT measurement and that of ultrasound pachymetry show good correlation. Pentacam pachymetry may be substituted for ultrasound in the post-LASIK patient.
引用
收藏
页码:75 / 80
页数:6
相关论文
共 50 条
  • [1] Evaluation of corneal thickness using a Scheimpflug-Placido disk corneal analyzer and comparison with ultrasound pachymetry in eyes after laser in situ keratomileusis
    Huang, Jinhai
    Lu, Weicong
    Savini, Giacomo
    Hu, Liang
    Pan, Chao
    Wang, Jing
    Tan, Weina
    Chen, Jia
    Wang, Qinmei
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (07): : 1074 - 1080
  • [2] A comparative analysis of five methods of determining corneal refractive power in eyes that have undergone myopic laser in situ keratomileusis
    Hamed, AH
    Wang, L
    Misra, M
    Koch, DD
    OPHTHALMOLOGY, 2002, 109 (04) : 651 - 658
  • [3] Comparison of Central Corneal Thickness Measurements by Galilei Dual-Scheimpflug Analyzer® and Ultrasound Pachymeter in Myopic Eyes
    Yeter, Volkan
    Sonmez, Baris
    Beden, Umit
    OPHTHALMIC SURGERY LASERS & IMAGING, 2012, 43 (02) : 128 - 134
  • [4] Relationship Between Central Epithelial Thickness and Central Corneal Thickness in Healthy Eyes and Eyes After Laser In Situ Keratomileusis
    Maltsev, Dmitrii S.
    Kudryashova, Elena V.
    Kulikov, Alexei N.
    Mareichev, Artem Yu.
    CORNEA, 2018, 37 (08) : 1053 - 1057
  • [5] Central and peripheral corneal thickness measured with optical coherence tomography, Scheimpflug imaging, and ultrasound pachymetry in normal, keratoconus-suspect, and post-laser in situ keratomileusis eyes
    Prospero Ponce, Claudia Maria
    Rocha, Karolinne Maia
    Smith, Scott D.
    Krueger, Ronald R.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (06): : 1055 - 1062
  • [6] Assessment of central corneal thickness in normal, keratoconus, and post-laser in situ keratomileusis eyes using Scheimpflug imaging, spectral domain optical coherence tomography, and ultrasound pachymetry
    Grewal, Dilraj S.
    Brar, Gagandeep S.
    Grewal, Satinder P. S.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (06): : 954 - 964
  • [7] Estimating the Preoperative Corneal Power With Scheimpflug Imaging in Eyes That Have Undergone Myopic LASIK
    Savini, Giacomo
    Hoffer, Kenneth J.
    Schiano-Lomoriello, Domenico
    Ducoli, Pietro
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (05) : 332 - 336
  • [8] CORNEAL FLAP THICKNESS DURING LASER IN SITU KERATOMILEUSIS
    Hsu, Sheng-Yao
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2007, 23 (01): : 25 - 29
  • [9] Corneal Thickness Measurement Using Orbscan, Pentacam, Galilei, and Ultrasound in Normal and Post-Femtosecond Laser In Situ Keratomileusis Eyes
    Park, Se-Hoon
    Choi, Suk-Kyue
    Lee, Doh
    Jun, Eun-Jung
    Kim, Jin-Hyoung
    CORNEA, 2012, 31 (09) : 978 - 982
  • [10] Comparison of central corneal thickness measurements with the Galilei dual Scheimpflug analyzer and ultrasound pachymetry
    Ladi, Jeevan S.
    Shah, Nitant A.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2010, 58 (05) : 385 - 388