A Monte Carlo simulation study to evaluate septal spacing using triple-head hybrid PET imaging

被引:4
|
作者
Groiselle, CJ [1 ]
D'Asseler, Y
Kolthammer, JA
Matthews, CG
Glick, SJ
机构
[1] Univ Massachusetts, Sch Med, Div Nucl Med, Worcester, MA 01655 USA
[2] Ghent Univ, Dept Elect & Informat Syst, B-9000 Ghent, Belgium
[3] Philips Med Syst, Cleveland, OH 44143 USA
[4] CTI CPS, Knoxville, TN 37932 USA
关键词
Monte Carlo simulation; positron emission tomography (PET); slat collimator;
D O I
10.1109/TNS.2003.817402
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The low coincidence fraction (ratio of true coincidences to single events detected) and a limited count rate capability reduce performance of hybrid PET systems as compared with dedicated PET. Axial collimation (i.e., using septa oriented perpendicular to the axis of rotation) has been used to reduce acceptance of photons from outside the field of view, reduce scattered events, and allow the use of 2-D image reconstruction algorithms. The major drawback of axial collimation is a reduced coincidence detection efficiency. The goal of this study was to evaluate the effect of axial collimator septal spacing, as well as to evaluate a new hybrid parallel-fan beam axial collimator design which may better shield out of field-of-view (FOV) photons, reduce the number of scattered events, and increase the sensitivity to the central FOV. The GEANT 3.21 Monte Carlo (MC) simulation code was modified to model a Philips IRIX triple-head hybrid PET system in the 0degrees - 90degrees - 270degrees geometry and used to investigate different axial collimator designs. Both lead and tungsten septa were investigated. Basic PET system parameters such as scatter fraction, global true coincidences to single events (T/S) ratio, axial profiles of the T/S ratio, and energy spectra Were examined. Noise equivalent count (NEC) rate curves were plotted. Noise and contrast, were evaluated for different collimator designs and reconstruction strategies. Comparisons to an experimentally acquired line source phantom showed that the GEANT 3.21 MC simulation code accurately modeled the Philips IRIX camera. The T/S ratio,was observed to increase with increasing septal spacing from 0.77 to 2.27 cm and was approximately constant for larger septal spacing. Widening the septal spacing modified the T/S axial profiles making them more nonuniform with a strong peak toward the axial center of the FOV. Using the hybrid parallel-fan beam axial collimator provided a more uniform axial T/S profile for some septal spacings and improved contrast and decreased the noise in the reconstructed slices. In addition, for a given single events rate, a larger proportion of single events were measured within the photopeak energy window as septal spacing decreased. This observation can have implications on the recorded random rate for some PET systems.
引用
收藏
页码:1339 / 1346
页数:8
相关论文
共 50 条
  • [1] A Monte-Carlo simulation study to evaluate septal spacing using triple-head hybrid PET imaging
    Groiselle, CJ
    Kolthammer, JA
    Matthews, CG
    Glick, SJ
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1190 - 1194
  • [2] PET imaging using a triple-head gamma camera
    Kuikka, JT
    Sohlberg, A
    Husso-Saastamoinen, M
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2002, 22 (05) : 328 - 331
  • [3] Conicidence PET with triple-head gamma camera using F-18FDG in oncolgy
    Oresic, B.
    Grosev, D.
    Jurasinovic, Z.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S380 - S380
  • [4] Hybrid Positron Emission Tomography (PET) Detector: A Feasibility Study with Monte Carlo Simulation
    Xiong, Z.
    Zhong, Y.
    Cheng, X.
    Hu, K.
    Shao, Y.
    MEDICAL PHYSICS, 2019, 46 (06) : E194 - E194
  • [5] Optimization of septal spacing in hybrid PET using estimation task performance
    Glick, SJ
    Groiselle, C
    Kolthammer, J
    Stodilka, RZ
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1195 - 1199
  • [6] Optimization of septal spacing in hybrid PET using estimation task performance
    Glick, SJ
    Groiselle, CJ
    Kolthammer, J
    Stodilka, RZ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2127 - 2132
  • [7] Treatment Verification Using Post-Treatment PET Imaging and Monte Carlo Simulation
    Beltran, C.
    Jia, Y.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [8] Molecular imaging of small animals with a triple-head SPECT system using pinhole collimation
    Metzler, SD
    Jaszczak, RJ
    Patil, NH
    Vemulapalli, S
    Akabani, G
    Chin, BB
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (07) : 853 - 862
  • [9] Optical Monte-Carlo Simulation to Evaluate Monolithic PET Detector Concepts
    Grahe, Jan
    Mueller, Florian
    Schug, David
    Hallen, Patrick
    Schulz, Volkmar
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [10] Dual-Resolution MicroSPECT Mouse Imaging Using a Triple-Head SPECT System
    Moore, Stephen C.
    Park, Mi-Ae
    Xia, Dan
    Metzler, Scott D.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,