Multicenter evaluation of a polyurethaneurea vascular access graft as compared with the expanded polytetrafluoroethylene vascular access graft in hemodialysis applications

被引:89
|
作者
Glickman, MH
Stokes, GK
Ross, JR
Schuman, ED
Sternbergh, WC
Lindberg, JS
Money, SM
Lorber, MI
机构
[1] Virginia Vasc Associates, Norfolk, VA 23502 USA
[2] Bambert Cty Hosp, Dept Surg, Bamberg, SC USA
[3] Oregon Surg Consultants, Portland, OR USA
[4] Ochsner Fdn Hosp, New Orleans, LA USA
[5] Yale New Haven Organ Transplant Ctr, New Haven, CT USA
关键词
D O I
10.1067/mva.2001.117330
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives. The purpose of this study was to compare in a randomized, prospective, and controlled study, the performance of a multilavered, self-sealing polyurethane vascular access graft (PVAG) and expanded polytetrafluoroethylene (ePTFE) vascular access grafts in hemodialysis applications. Performance measures included graft survival, complications, time to early cannulation, and hemostasis times after cannulation. Study Design: A total of 142 patients were randomized equally to receive one of the two grafts after meeting all eligibility requirements. All patients were followed up prospectively to 12 months or to the end of secondary patency. Specifically, this study documented the performance of the PVAG and cPTFE grafts by determining the patencies and complications for both grafts. Results. Patient characteristics between the two groups were similar with respect to risk factors and demographic characteristics (P>.05).Life-table patencies from the date of first dialysis were primary patency: PVAG 55% versus ePTFE 47% (6 months) and PVAG 44% versus ePTFE 36% (12 months) and secondary patency: PVAG 87% versus ePTFE 90% (6 months) and PVAG 78% versus ePTFE 80% (12 months). None of these differences were significant (P>.05). Both primary and secondary patencies were also not significantly different when the date of implantation was the starting point. Adverse events and complications were similar for the two groups, except the PVAG group had a higher incidence of technical complications manifested by graft kinking when compared with the control cohort (P<.05). Additionally, there was no significant difference in complication rates between these two groups with regard to infection and bleeding. When the time to hemostasis after cannulation was compared at 5 minutes or less, there were more PVAG cannulation sites that achieved hemostasis compared with ePTFE sites, and this difference was significant (P<.0001). When time to first dialysis access was compared between the two grafts, 53.9% of all PVAG grafts were cannulated before 9 days versus none with the ePTFE grafts (P<.001). However, long-term graft survival was not significantly different when PVAG patients were stratified into early (<9 days) and the late access (9 greater than or equal to days) groups (P=.29). Conclusions. The PVAG graft allows for early access without compromising long-term performance. Both PVAG and standard ePTFE grafts have similar long-term outcomes, despite early access with the PVAG vascular access grafts.
引用
收藏
页码:465 / 472
页数:8
相关论文
共 50 条
  • [1] Prospective, randomized evaluation of a cuffed expanded polytetrafluoroethylene graft for hemodialysis vascular access
    Sorom, AJ
    Hughes, CB
    McCarthy, JT
    Jenson, BM
    Prieto, M
    Panneton, JM
    Sterioff, S
    Stegall, MD
    Nyberg, SL
    SURGERY, 2002, 132 (02) : 135 - 140
  • [2] A polyurethane vascular access graft and a hybrid polytetrafluoroethylene graft as an arteriovenous fistula for hemodialysis: Comparison with an expanded polytetrafluoroethylene graft
    Matsuda, H
    Miyazaki, M
    Oka, Y
    Nakao, A
    Choda, Y
    Kokumai, Y
    Kunitomo, K
    Tanaka, N
    ARTIFICIAL ORGANS, 2003, 27 (08) : 722 - 727
  • [3] Hybrid arteriovenous graft for hemodialysis vascular access in a multicenter registry
    Benedetto, Filippo
    Spinelli, Domenico
    Pipito, Narayana
    Menegolo, Mirko
    Tozzi, Matteo
    Giubbolini, Michele
    Bracale, Umberto Marcello
    Frigerio, Dalmazio
    Agostinucci, Andrea
    Scolaro, Antonino
    Alibrandi, Angela
    Pratesi, Carlo
    Setacci, Carlo
    Derone, Graziana
    Grego, Franco
    Franchin, Marco
    Piffaretti, Gabriele
    Castelli, Patrizio
    Morale, Walter
    Giacomelli, Elena
    Innocenti, Alessandro Alessi
    Mazzitelli, Giulia
    Gagliardo, Giambattista
    JOURNAL OF VASCULAR SURGERY, 2019, 70 (06) : 1904 - +
  • [4] CLINICAL EXPERIENCE WITH CIRCUMFERENTIALLY REINFORCED, EXPANDED POLYTETRAFLUOROETHYLENE (E-PTFE) GRAFT AS A VASCULAR ACCESS FOR HEMODIALYSIS
    OTA, K
    ARA, R
    TAKAHASHI, K
    TOMA, H
    AGISHI, T
    KIDNEY INTERNATIONAL, 1977, 12 (01) : 85 - 86
  • [5] EXPANDED POLYTETRAFLUOROETHYLENE GRAFTS FOR VASCULAR ACCESS IN HEMODIALYSIS - LABORATORY AND CLINICAL EVALUATION
    ELLIOTT, MP
    GAZZANIGA, AB
    THOMAS, JM
    HAIDUC, NJ
    ROSEN, SM
    AMERICAN SURGEON, 1977, 43 (07) : 455 - 459
  • [6] A multilayered electrospun graft as vascular access for hemodialysis
    Radakovic, D.
    Reboredo, J.
    Helm, M.
    Weigel, T.
    Schuerlein, S.
    Kupczyk, E.
    Leyh, R. G.
    Walles, H.
    Hansmann, J.
    PLOS ONE, 2017, 12 (10):
  • [7] Aneurysm of an expanded polytetrafluoroethylene vascular graft:: an ultrastructural evaluation
    Chakfé, N
    Dieval, F
    Thaveau, F
    Taghavi, I
    Le Magnen, JF
    Laroche, G
    Hassani, O
    Riepe, G
    Durand, B
    Kretz, JG
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2003, 25 (04) : 360 - 366
  • [8] Pasteurella multocida-Infected Expanded Polytetrafluoroethylene Hemodialysis Access Graft
    Schneider, Joseph R.
    White, G. Wesley
    DeJesus, Ernest F.
    ANNALS OF VASCULAR SURGERY, 2012, 26 (08)
  • [10] AN EVALUATION OF EXPANDED POLYTETRAFLUOROETHYLENE (PTFE) LOOP GRAFTS IN THE THIGH AS VASCULAR ACCESS FOR HEMODIALYSIS IN PATIENTS WITH ACCESS PROBLEMS
    SLATER, ND
    RAFTERY, AT
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 1988, 70 (04) : 243 - 245