Optimizing dose and administration regimen of a high-relaxivity contrast agent for myocardial MRI late gadolinium enhancement

被引:8
|
作者
Secchi, Francesco
Di Leo, Giovanni
Papini, Giacomo D. E.
Giacomazzi, Francesca [2 ]
Di Donato, Marisa [3 ]
Sardanelli, Francesco [1 ]
机构
[1] Univ Milan, Dipartimento Sci Med Chirurg, IRCCS Policlin San Donato, Unita Radiol, I-20097 Milan, Italy
[2] IRCCS Policlin San Donato, Unit Cardiac Surg, I-20097 Milan, Italy
[3] Univ Florence, Dept Crit Care Med, IRCCS Policlin San Donato, I-20097 Milan, Italy
关键词
Cardiac magnetic resonance; Contrast-to-noise ratio; Dose finding; Late gadolinium enhancement; Myocardial infarction; NEPHROGENIC SYSTEMIC FIBROSIS; GADOBENATE DIMEGLUMINE; DELAYED-ENHANCEMENT; GADOPENTETATE DIMEGLUMINE; INFARCT; TIME; ANGIOGRAPHY; RECOVERY; COIL; FEASIBILITY;
D O I
10.1016/j.ejrad.2010.06.040
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To investigate the time-course of late gadolinium enhancement of infarcted myocardium using gadobenate dimeglumine at different dosages and administration regimens. Materials and methods: After institutional review board approval and informed consent, we studied 13 patients (aged 63 +/- 11 years) with chronic myocardial infarction. They underwent two gadobenate dimeglumine-enhanced MR examinations (interval 24-48 h) using short-axis inversion-recovery gradient-echo sequences, with the following two different protocols, in randomized order: 0.05 mmol/kg and imaging at the 2.5th, 5th, 7.5th and 10th minute plus 0.05 mmol/kg and imaging at the 12.5th, 15th, 17.5th and 20th minute; the same as before but using 0.1 mmol/kg for both contrast injections. Contrast-to-noise ratios (CNRs) between infarcted myocardium, non-infarcted myocardium and left ventricle cavity were calculated for each time-point (2.5-min steps). Friedman ANOVA was used for comparing the CNR time-course; Wilcoxon test for comparing CNR at the 10th and the 20th minute. Results: The CNR between infarcted and non-infarcted myocardium obtained at the 20th minute with 0.05 plus 0.05 mmol/kg resulted significantly higher than that obtained at the 10th minute with 0.05 mmol/kg (P = 0.033) while not significantly different from that obtained at the 10th (0.1 mm/kg) or at the 20th minute with 0.1 plus 0.1 mmol/kg. The CNR between infarcted myocardium and the left ventricle cavity obtained at the 20th minute with 0.05 plus 0.05 mmol/kg resulted significantly higher than all other measured values (P <= 0.017). Conclusion: Using gadobenate dimeglumine, 0.05 plus 0.05 mmol/kg allows for a higher CNR between infarcted myocardium and the left ventricle cavity allowing for reliable assessment of the sub-endocardial infarctions. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:96 / 102
页数:7
相关论文
共 50 条
  • [1] Breast MRI Using a High-Relaxivity Contrast Agent: An Overview
    Carbonaro, Luca A.
    Pediconi, Federica
    Verardi, Nicola
    Trimboli, Rubina M.
    Calabrese, Massimo
    Sardanelli, Francesco
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (04) : 942 - 955
  • [2] Gold Nanoparticles Functionalized with Gadolinium Chelates as High-Relaxivity MRI Contrast Agents
    Moriggi, Loick
    Cannizzo, Caroline
    Dumas, Eddy
    Mayer, Cedric R.
    Ulianov, Alexey
    Helm, Lothar
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2009, 131 (31) : 10828 - +
  • [3] Preclinical Safety Assessment of Gadopiclenol: A High-Relaxivity Macrocyclic Gadolinium-Based MRI Contrast Agent
    Gendron, Celia
    Bourrinet, Philippe
    Dencausse, Anne
    Fretellier, Nathalie
    INVESTIGATIVE RADIOLOGY, 2024, 59 (02) : 108 - 123
  • [4] Hybrid Dextran-gadolinium Nano-suitcases as High-relaxivity MRI Contrast Agents
    Hao Wang
    Ting-Ting Dai
    Bo-Lun Lu
    Sheng-Li Li
    Qing Lu
    Vincent Mukwaya
    Hong-Jing Dou
    Chinese Journal of Polymer Science, 2018, 36 : 391 - 398
  • [5] Hybrid Dextran-gadolinium Nano-suitcases as High-relaxivity MRI Contrast Agents
    Hao Wang
    Ting-Ting Dai
    Bo-Lun Lu
    Sheng-Li Li
    Qing Lu
    Vincent Mukwaya
    Hong-Jing Dou
    Chinese Journal of Polymer Science, 2018, (03) : 391 - 398
  • [6] Hybrid Dextran-gadolinium Nano-suitcases as High-relaxivity MRI Contrast Agents
    Wang, Hao
    Dai, Ting-Ting
    Lu, Bo-Lun
    Li, Sheng-Li
    Lu, Qing
    Mukwaya, Vincent
    Dou, Hong-Jing
    CHINESE JOURNAL OF POLYMER SCIENCE, 2018, 36 (03) : 391 - 398
  • [7] Adaption of the structure of carbon nanohybrids toward high-relaxivity for a new MRI contrast agent
    Li, Juan
    Cui, Rongli
    Chang, Yanan
    Guo, Xihong
    Gu, Weihong
    Huang, Huan
    Chen, Kui
    Lin, Guoming
    Dong, Jinquan
    Xing, Gengmei
    Sun, Baoyun
    RSC ADVANCES, 2016, 6 (63) : 58028 - 58033
  • [8] Multivalent, High-Relaxivity MRI Contrast Agents Using Rigid Cysteine-Reactive Gadolinium Complexes
    Garimella, Praveena D.
    Datta, Ankona
    Romanini, Dante W.
    Raymond, Kenneth N.
    Francis, Matthew B.
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2011, 133 (37) : 14704 - 14709
  • [9] High-relaxivity MRI contrast agents prepared from miniemulsion polymerization using gadolinium(III)-based metallosurfactants
    Gong, Pei
    Chen, Zhengyan
    Chen, Yingying
    Wang, Wei
    Wang, Xiaosong
    Hu, Aiguo
    CHEMICAL COMMUNICATIONS, 2011, 47 (14) : 4240 - 4242
  • [10] Manganese(III) porphyrin oligomers as high-relaxivity MRI contrast agents
    Lu, Hui-Shan
    Wang, Meng-Yi
    Ying, Fei-Peng
    Lv, Yuan-Yuan
    BIOORGANIC & MEDICINAL CHEMISTRY, 2021, 35