Optimisation of Pt sensitivity in PIXE analysis of thin biological samples

被引:3
|
作者
Tiourina, TB [1 ]
Mutsaers, PHA [1 ]
de Voigt, MJA [1 ]
机构
[1] Eindhoven Univ Technol, Dept Appl Phys, Cyclotron Lab, NL-5600 MB Eindhoven, Netherlands
关键词
sensitivity optimisation; particle induced X-ray emission;
D O I
10.1016/S0168-583X(97)01003-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
To obtain Pt concentration distributions in tumor biopsies, micro-PIXE is used. The Limit of Detection (LOD) for Pt is determined by the background production cross section together with the production cross section for the Pt-L lines. Both are functions of the type and energy of the projectile. In order to optimise the experimental conditions, the proton energy is varied from 2.5 to 5 MeV and the corresponding X-ray spectra are analysed. The optimum LOD is about 1 mu g/g for a sample thickness of 1 mg/cm(2) and a total charge of 100 mu C. A study is performed to investigate the possibility of elemental analysis by means of alpha excitation. The corresponding LOD is 6 mu g/g with 200 mu C charge (He++ was used). For alpha excitation, sample damage limits the beam current and, thus, causes a tremendous increase in the measurement time. (C) 1998 Published by Elsevier Science B.V.
引用
收藏
页码:186 / 191
页数:6
相关论文
共 50 条
  • [1] DETECTION LIMIT AND SENSITIVITY IN PIXE ANALYSIS OF THICK SAMPLES
    GARTEN, RPH
    GROENEVELD, KO
    KONIG, KH
    SCHADER, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (01) : 1381 - 1383
  • [2] DETECTION LIMIT AND SENSITIVITY IN PIXE ANALYSIS IN THICK SAMPLES
    GARTEN, RPH
    GROENEVELD, KO
    KONIG, KH
    SCHADER, J
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (08): : 1055 - 1055
  • [3] PIXE ANALYSIS OF THICK TARGET BIOLOGICAL SAMPLES IN VACUUM
    CLAYTON, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 22 (1-3): : 145 - 148
  • [4] ELIMINATION OF CHARGING IN PIXE ANALYSIS OF THICK BIOLOGICAL SAMPLES
    PAPPER, CS
    CHAUDHRI, MA
    ROUSE, JL
    NUCLEAR INSTRUMENTS & METHODS, 1978, 154 (02): : 219 - 221
  • [5] PIXE APPLICATIONS IN ELEMENTAL ANALYSIS OF BIOLOGICAL AND METALLURGICAL SAMPLES
    Popescu, I. V.
    Ene, A.
    Stihi, C.
    Gheboianu, A.
    Badica, T.
    JOURNAL OF SCIENCE AND ARTS, 2007, 7 : 7 - 12
  • [6] A PIXE-PIGE SETUP FOR THE ANALYSIS OF THIN SAMPLES
    BONI, C
    CARIDI, A
    CEREDA, E
    MARCAZZAN, GMB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 47 (02): : 133 - 142
  • [7] On the applications of IBA techniques to biological samples analysis:: PIXE and RBS
    Falcon-Gonzalez, J. M.
    Bernal-Alvarado, J.
    Garcia-Leon, M.
    Garcia-Tenorio, R.
    Garcia, Y. Morilla
    Sosa, M.
    MEDICAL PHYSICS, 2008, 1032 : 179 - +
  • [8] SIMULTANEOUS PIXE-PIGE ANALYSIS OF THIN AND THICK SAMPLES
    BONI, C
    CARIDI, A
    CEREDA, E
    MARCAZZAN, GMB
    REDAELLI, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 49 (1-4): : 106 - 110
  • [9] PIXE PIGE ANALYSIS OF THIN FLY-ASH SAMPLES
    BONI, C
    CARIDI, A
    CEREDA, E
    MARCAZZAN, GMB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 45 (1-4): : 352 - 355
  • [10] HIGH-SENSITIVITY PIXE DETERMINATION OF SELENIUM IN BIOLOGICAL SAMPLES USING A PRECONCENTRATION TECHNIQUE
    BUSO, GP
    COLAUTTI, P
    MOSCHINI, G
    HU, XS
    STIEVANO, BM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1984, 3 (1-3): : 177 - 180