Preliminary Comparison Study of Two Electro-Mechanical Cardiopulmonary Resuscitation Devices

被引:0
|
作者
Garcia, Alejandro Mendoza [1 ]
Eichhorn, Stefan [2 ]
Stroh, Annemarie [2 ]
Polski, Marcin [2 ]
Knoll, Alois [1 ]
机构
[1] Tech Univ Munich, Fak Informat Robot & Embedded Syst, Munich, Germany
[2] Tech Univ Munich, Clin Cardiovasc Surg, German Heart Ctr Munich, Munich, Germany
关键词
CARDIAC-ARREST; COMPRESSION;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
New electro-mechanical cardiopulmonary resuscitation devices may help in providing more constant compressions in depth and compression rate to patients suffering from cardiac arrest. They are easily transportable and allow paramedics to move patients even while applying CPR. The behaviour of these devices however may be different even when using the same guidelines for the effective application of CPR. The presented study shows the hemodynamic and gas exchange response in the application of the Lucas2 and Corpuls CPR device with the use of an animal model. A description of the acquisition system is given and the protocol followed during the experimental procedure.
引用
收藏
页码:81 / 84
页数:4
相关论文
共 50 条
  • [1] Simulation of an Electro-Mechanical Resuscitation Device for Cardiopulmonary Resuscitation
    Garcia, Alejandro Mendoza
    Eichhorn, Stefan
    Polski, Marcin
    Knoll, Alois
    2014 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 41, 2014, 41 : 1049 - 1052
  • [2] Mechanical devices for cardiopulmonary resuscitation
    Wigginton, JG
    Miller, AH
    Benitez, FL
    Pepe, PE
    CURRENT OPINION IN CRITICAL CARE, 2005, 11 (03) : 219 - 223
  • [3] Mechanical devices for cardiopulmonary resuscitation
    Wigginton, Jane G.
    Isaacs, S. Marshal
    Kay, Joseph J.
    CURRENT OPINION IN CRITICAL CARE, 2007, 13 (03) : 273 - 279
  • [4] Mechanical Devices for Cardiopulmonary Resuscitation
    Halperin, Henry
    CRITICAL CARE CLINICS, 2012, 28 (02) : 167 - +
  • [5] Use of mechanical resuscitation devices in cardiopulmonary resuscitation
    Luxen, J. P.
    Birkholz, T.
    Hatz, A.
    Kanz, K. -G.
    Koeniger, J.
    Meier, M.
    Urban, B.
    Trentzsch, H.
    NOTFALL & RETTUNGSMEDIZIN, 2015, 18 (02): : 119 - 129
  • [6] Cardiopulmonary Resuscitation Devices: Preliminary Analysis
    Adamini, Riccardo
    Aggogeri, Francesco
    Baronio, Manuela
    Borboni, Alberto
    Dal Gal, Elisabetta
    Pellegrini, Nicola
    Remino, Carlo
    ADVANCES IN SERVICE AND INDUSTRIAL ROBOTICS, 2018, 49 : 885 - 891
  • [7] CALCULATION AND DESIGN OF ELECTRO-MECHANICAL DEVICES
    ALDEFELD, B
    PHILIPS TECHNICAL REVIEW, 1980, 39 (3-4): : 78 - 86
  • [8] Mechanical devices for cardiopulmonary resuscitation: an update
    Lurie, K
    EMERGENCY MEDICINE CLINICS OF NORTH AMERICA, 2002, 20 (04) : 771 - +
  • [9] Update on mechanical cardiopulmonary resuscitation devices
    Rubertsson, Sten
    CURRENT OPINION IN CRITICAL CARE, 2016, 22 (03) : 225 - 229
  • [10] PARAMETRIC OSCILLATORY MOTION IN ELECTRO-MECHANICAL DEVICES
    SMITH, BH
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1979, 126 (08): : 778 - 780