Fabrication of Tips for Magnetic Force Microscopy Employing Magnetic Multilayer Structures

被引:2
|
作者
Suzuki, Ryo [1 ]
Ishihara, Shinji [1 ]
Ohtake, Mitsuru [1 ]
Futamoto, Masaaki [1 ]
机构
[1] Chuo Univ, Fac Sci & Engn, Tokyo 1128551, Japan
关键词
magnetic force microscope; tip; spatial resolution; switching field; multilayer film coating;
D O I
10.4028/www.scientific.net/KEM.605.465
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Magnetic force microscope (MFM) tips are prepared by coating Si tips of 4 nm radius with [Co(1 nm)/M(1 nm)](20) (M = Pt, Pd, Ni) multilayer films. An MFM tip prepared by coating 40- nm- thick Co film is employed as a reference tip. The influences of M layer material on the spatial resolution and the switching field of MFM tip are investigated. The spatial resolutions of Co/M multilayer coated tips are estimated to be within 9.4 +/- 0.3 nm for all the M materials, which is about 6% inferior to that of Co coated tip (8.8 nm). Higher switching fields of 1425 and 825 Oe are respectively observed for the tips coated with Co/Pt and Co/Pd multilayers, whereas the field of tip coated with Co/Ni multilayer is 275 Oe which is similar to that of Co coated tip (325 Oe). The switching field is influenced by the magnetic anisotropy of multilayer film. An MFM tip coated with Co/Pt multilayer film is useful to observe the magnetic domain structure of permanent magnets and magnetic recording media.
引用
收藏
页码:465 / 469
页数:5
相关论文
共 50 条
  • [1] Fabrication of Magnetic Tips for High-Resolution Magnetic Force Microscopy
    Futamoto, Masaaki
    Hagami, Tatsuya
    Ishihara, Shinji
    Soneta, Kazuki
    Ohtake, Mitsuru
    MATERIALS AND APPLICATIONS FOR SENSORS AND TRANSDUCERS II, 2013, 543 : 35 - 38
  • [2] Magnetic refinement of tips for magnetic force microscopy
    Bauer, P
    Bochem, HP
    Leinebach, P
    Memmert, U
    Schelten, J
    SCANNING, 1996, 18 (05) : 374 - 378
  • [3] STUDY OF MAGNETIC CHARACTERISTICS OF TIPS FOR MAGNETIC FORCE MICROSCOPY
    SUEOKA, K
    SAI, F
    PARKER, K
    ARNOLDUSSEN, T
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1994, 12 (03): : 1618 - 1622
  • [4] Superparamagnetic magnetic force microscopy tips
    Hopkins, PF
    Moreland, J
    Malhotra, SS
    Liou, SH
    JOURNAL OF APPLIED PHYSICS, 1996, 79 (08) : 6448 - 6450
  • [5] Magnetic elements for switching magnetization magnetic force microscopy tips
    Cambel, V.
    Elias, P.
    Gregusova, D.
    Martaus, J.
    Fedor, J.
    Karapetrov, G.
    Novosad, V.
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2010, 322 (18) : 2715 - 2721
  • [6] Force microscopy - Magnetic tips probe the nanoworld
    Meyer, Ernst
    Rast, Simon
    NATURE NANOTECHNOLOGY, 2007, 2 (05) : 267 - 268
  • [7] A method for the calibration of magnetic force microscopy tips
    van Schendel, PJA
    Hug, HJ
    Stiefel, B
    Martin, S
    Güntherodt, HJ
    JOURNAL OF APPLIED PHYSICS, 2000, 88 (01) : 435 - 445
  • [8] Micromagnetic model for magnetic force microscopy tips
    Tomlinson, SL
    Farley, AN
    JOURNAL OF APPLIED PHYSICS, 1997, 81 (08) : 5029 - 5031
  • [9] Method for the calibration of magnetic force microscopy tips
    van, Schendel, P.J.A.
    Hug, H.J.
    Stiefel, B.
    Martin, S.
    Guntherodt, H.-J.
    Journal of Applied Physics, 2000, 88 (01)
  • [10] Micromagnetic model for magnetic force microscopy tips
    Tomlinson, S.L.