Morphometric study of the left atrial appendage related to closure device deployment: a cadaveric study in Thai population

被引:2
|
作者
Panyawongkhanti, M. [1 ]
Fuktongphan, P. [1 ]
Chentanez, V [1 ]
机构
[1] Chulalongkorn Univ, Dept Anat, King Chulalongkorn Mem Hosp, Fac Med, Bangkok, Thailand
关键词
left atrial appendage (LAA); functional depth of LAA; LAA closure; left superior pulmonary vein; ostium diameter; ostium shape; ostium surface area; CARDIOGENIC STROKE; FLOW VELOCITY; MORPHOLOGY; FIBRILLATION; ANATOMY; RISK; THROMBUS; SYSTEM;
D O I
10.5603/FM.a2019.0066
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Background: This study aims to investigate the left atrial appendage (LAA) regarding external morphology, positional relation of the ostium of LAA to the left superior pulmonary vein (LSPV), ostium shape, ostium diameter and functional depth. Materials and methods: Left atrial appendages of 65 cadaveric hearts were examined. Results: The prevalence of Cauliflower, Windsock, Cactus and Chicken wing type of LAA were 27.7%, 27.7%, 26.1%, and 18.5%, respectively. MA with two lobes was the most common. All specimens showed no accessory LAA. The relation of the ostium to the LSPV was found in two types which were mid-type (LAA ostium was at the same level as LSPV) in 29 (44.6%) cases and inferior type (LAA ostium was below the level of LSPV) in 36 (55.4%) cases. The shapes of MA ostium were oval and round with a prevalence of 55.4% and 44.6%, respectively. The diameter of round type ranged from 9.53 to 21.51 mm with a mean of 14.56 +/- 2.6 mm. While in oval type, the long and short diameters ranged from 11.61 to 31.71 mm with a mean of 14.23 +/- 4.2 mm and from 6.70 to 23.90 mm with a mean of 11.66 +/- 3.5 mm, respectively. The surface area of the ostium was calculated from the ostium diameter, range from 71.29 to 594.92 mm(2) with a mean of 169.56 +/- 84.73 mm(2). There was no statistically significant difference of the surface area between MA types. The mean functional depth of MA was 11.57 +/- 4.43 mm. The functional depth of the Windsock-type appeared to be statistically significant from the others. However; there was no correlation between the functional depth and the ostium surface area. Conclusions: This morphometric data might be beneficial for deployment of LAA closure device in the Thai population.
引用
收藏
页码:79 / 85
页数:7
相关论文
共 50 条
  • [1] Left atrial appendage perforation during percutaneous deployment of a left atrial appendage closure device placement
    Shaygan, Lida
    Rajagopal, Arvind
    Tuman, Kenneth
    JOURNAL OF CLINICAL ANESTHESIA, 2020, 59 : 5 - 6
  • [2] Left Atrial Appendage Closure Device in Atrial Fibrillation
    Giudici, Michael C.
    Bhave, Prashant D.
    CARDIOLOGY CLINICS, 2017, 35 (02) : 297 - +
  • [3] Embolization of a left atrial appendage closure device
    Nunes, Alzira
    Pissarra, Diana
    Silva, Marta Tavares
    Almeida, Pedro Bernardo
    Silva, Joao Carlos
    Maciel, Maria Julia
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2021, 40 (03) : 247 - 248
  • [4] Double device left atrial appendage closure
    Guerios, Enio E.
    Gloekler, Steffen
    Schmid, Michael
    Khattab, Ahmed
    Nietlispach, Fabian
    Meier, Bernhard
    EUROINTERVENTION, 2015, 11 (04) : 470 - 476
  • [5] Left Atrial Appendage Closure - The WATCHMAN Device
    Akinapelli, Abhilash
    Bansal, Ojas
    Chen, Jack P.
    Pflugfelder, Alex
    Gordon, Nicole
    Stein, Kenneth
    Huibregtse, Barbara
    Hou, Dongming
    CURRENT CARDIOLOGY REVIEWS, 2015, 11 (04) : 334 - 340
  • [6] Left Atrial Appendage Closure With the Watchman Device in Patients With a Contraindication for Oral Anticoagulation The ASAP Study (ASA Plavix Feasibility Study With Watchman Left Atrial Appendage Closure Technology)
    Reddy, Vivek Y.
    Moebius-Winkler, Sven
    Miller, Marc A.
    Neuzil, Petr
    Schuler, Gerhard
    Wiebe, Jens
    Sick, Peter
    Sievert, Horst
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (25) : 2551 - 2556
  • [7] The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation
    Moebius-Winkler, Sven
    Sandri, Marcus
    Mangner, Norman
    Lurz, Phillip
    Daehnert, Ingo
    Schuler, Gerhard
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2012, (60):
  • [8] Temporal Evolution and Incidence of Device Related Thrombus in Left Atrial Appendage Closure
    Alabre, Alisha
    Savona, Salvatore
    Hummel, John
    Afzal, Muhammad Rizwan
    CIRCULATION, 2024, 150
  • [9] Deployment of left atrial appendage occlusion device in large aneurysmal left atrial appendage: a case report
    Fadel, Raef
    Khan, Essaq
    Maskoun, Waddah
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2024, 8 (03)
  • [10] Device related thrombus after left atrial appendage closure: State of the art
    Yu, Jiangtao
    Bai, Yuan
    Jiang, Li-Sheng
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (07): : 1253 - 1258