A Software Tool for the Computation of Arterial Pulse Wave Velocity from Flow-sensitive 4D MRI Data

被引:0
|
作者
Drexl, J. [1 ]
Mirzaee, H. [1 ]
Harloff, A. [2 ]
Huellebrand, M. [1 ]
Hennemuth, A. [1 ]
Hahn, H. [1 ]
机构
[1] Fraunhofer MEVIS, Bremen, Germany
[2] Univ Freiburg, Univ Hosp, Dept Neurol, Freiburg, Germany
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Recently, Markl at al. [1] demonstrated that the aortic pulse wave velocity (PWV) can be measured non-invasively based on flow-sensitive 4D MRI. However, the suggested post-processing workflow is very time consuming. in this paper, we present a more efficient PWV computation integrated into a dedicated software assistant, supporting all major steps for PWV computation. The implementation was validated on a digital phantom. Furthermore, two independent observers re-processed the volunteer data from the Markl et al. study with our software, so that outcomes as well as processing times could be compared. The implementation of our method gives similar accuracy and reproducibility to the method of Markl at al, but at a significantly reduced processing time.
引用
收藏
页码:559 / 562
页数:4
相关论文
共 50 条
  • [1] Estimation of Global Aortic Pulse Wave Velocity by Flow-Sensitive 4D MRI
    Markl, Michael
    Wallis, Wolf
    Brendecke, Stefanie
    Simon, Jan
    Frydrychowicz, Alex
    Harloff, Andreas
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (06) : 1575 - 1582
  • [2] Aortic pulse wave velocity measurements with undersampled 4D flow-sensitive MRI: comparison with 2D and algorithm determination
    Wentland, Andrew L.
    Wieben, Oliver
    Francois, Chris J.
    Boncyk, Christina
    Del Rio, Alejandro Munoz
    Johnson, Kevin M.
    Grist, Thomas M.
    Frydrychowicz, Alex
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (04) : 853 - 859
  • [3] Assessing cerebral arterial pulse wave velocity using 4D flow MRI
    Bjornfot, Cecilia
    Garpebring, Anders
    Qvarlander, Sara
    Malm, Jan
    Eklund, Anders
    Wahlin, Anders
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2021, 41 (10): : 2769 - 2777
  • [4] In Vitro Validation of 4D Flow MRI for Local Pulse Wave Velocity Estimation
    Timothy Ruesink
    Rafael Medero
    David Rutkowski
    Alejandro Roldán-Alzate
    Cardiovascular Engineering and Technology, 2018, 9 : 674 - 687
  • [5] In Vitro Validation of 4D Flow MRI for Local Pulse Wave Velocity Estimation
    Ruesink, Timothy
    Medero, Rafael
    Rutkowski, David
    Roldan-Alzate, Alejandro
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2018, 9 (04) : 674 - 687
  • [6] Patient Specific Hemodynamics: Combined 4D Flow-Sensitive MRI and CFD
    Stalder, A. F.
    Liu, Z.
    Hennig, J.
    Korvink, J. G.
    Li, K. C.
    Markl, M.
    COMPUTATIONAL BIOMECHANICS FOR MEDICINE: SOFT TISSUES AND THE MUSCULOSKELETAL SYSTEM, 2011, : 27 - 38
  • [7] Aortic Pulse Wave Velocity Evaluated by 4D Flow MRI Across the Adult Lifespan
    Jarvis, Kelly
    Scott, Michael B.
    Soulat, Gilles
    Elbaz, Mohammed S. M.
    Barker, Alex J.
    Carr, James C.
    Markl, Michael
    Ragin, Ann
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 56 (02) : 464 - 473
  • [8] Analysis of right heart flow patterns in repaired Tetralogy of Fallot with 4D flow-sensitive MRI
    Christopher J Francois
    Shardha Srinivasan
    Benjamin R Landgraf
    Eric Niespodzany
    Oliver Wieben
    Alex Frydrychowicz
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [9] Editorial for "Aortic Pulse Wave Velocity Evaluated by 4D Flow MRI Across the Adult Lifespan"
    Fyrdahl, Alexander
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 56 (02) : 474 - 475
  • [10] Interpolation time-optimized aortic pulse wave velocity estimation by 4D flow MRI
    Sungho Park
    Minseong Kwon
    Hyojin Nam
    Hyungkyu Huh
    Scientific Reports, 13