Behavior of Square Hollow Section column connection using Thread-anchored One-side Bolt under tensile force at high temperature

被引:8
|
作者
Liu, Yuanjian [1 ,2 ]
You, Yang [1 ]
Bai, Yunyan [1 ]
Cheng, Tianxi [1 ]
Wang, Peijun [1 ]
Zhang, Wenchao [1 ]
Liu, Fangzhou [1 ]
机构
[1] Shandong Univ, Sch Civil Engn, Jinan 250061, Shandong, Peoples R China
[2] China Railway Grp Ltd, Beijing 100036, Peoples R China
来源
JOURNAL OF BUILDING ENGINEERING | 2022年 / 50卷
基金
中国国家自然科学基金;
关键词
Thread bolt hole; One-side bolt; Tensile behavior; Square hollow section; High temperature; FIRE PERFORMANCE; STRENGTH;
D O I
10.1016/j.jobe.2022.104150
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A series of tests including 30 specimens were conducted to study the tensile performance of Thread-anchored One-side Bolted (TOB) Square Hollow Section (SHS) column connections at high temperature. Ambient temperature test was conducted firstly to acquire basic tensile behavior of the TOB bolted SHS column connection. Then both steady-state fire test and transient state fire test were carried out on the basis of ambient temperature test. Four typical failure modes of TOB bolted SHS column connection were observed in test. The thickness of the SHS column wall, the bolt diameter and thickness of the T-stub flange had obvious influence on the failure mode of TOB bolted SHS column connection. But the change of temperature or applied load had negligible impact on the failure mode. The hole threads could provide reliable anchorage to TOB before the yielding of the connection, which demonstrated the reliability of the novel TOB at different temperatures. The fire temperature and the load ratio had great influence of the tensile resistance of connection at high temperature. Test on connections bolted by Traditional High strength Bolt (THB) were also conducted for comparison. Result showed the tensile behavior of TOB connection was comparable to THB connection at high temperature when the failure mode of the connection was T-stub flange yielding with bolt failure. Equations for predicting the failure mode and resistance of TOB bolted connections at high temperature were proposed. Accuracy of the design equations were validated with the test result. The equations could judge the failure mode precisely and predict the yielding load with enough accuracy.
引用
收藏
页数:17
相关论文
共 15 条
  • [1] Fire behavior of novel Thread-anchored One-side bolted connection with internal component
    You, Yang
    Gu, Hangping
    Wang, Qishuai
    Cheng, Tianxi
    Wang, Peijun
    Zhang, Wenchao
    Liu, Fangzhou
    Zhai, Guangjun
    Journal of Constructional Steel Research, 2022, 194
  • [2] Fire behavior of novel Thread-anchored One-side bolted connection with internal component
    You, Yang
    Gu, Hangping
    Wang, Qishuai
    Cheng, Tianxi
    Wang, Peijun
    Zhang, Wenchao
    Liu, Fangzhou
    Zhai, Guangjun
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 194
  • [3] Post-fire behavior of square hollow section column connections using thread-anchored blind bolts
    You, Yang
    Li, Yang
    Lin, Chunjin
    Wang, Peijun
    Jiang, Jian
    Ye, Jihong
    STRUCTURES, 2024, 59
  • [4] Seismic behavior of thread-fixed one-side bolted endplate connection of steel beam to hollow square column
    Zhang, Boxun
    Yuan, Haotian
    Xia, Chengxin
    Liu, Xinyu
    Liu, Mei
    Liu, Fangzhou
    Wang, Peijun
    JOURNAL OF BUILDING ENGINEERING, 2021, 43
  • [5] Numerical studies on yield line patterns of thread-fixed one-side bolted endplate connection to square hollow section column under tension
    Zhang, Yue
    Wang, Peijun
    Liu, Mei
    Liu, Yuanjian
    Zhang, Boxun
    Zhou, Shengzhan
    Chen, Junxia
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 173
  • [6] Proposed analytical models for bolted T-stubs to square hollow section column connection using thread-fixed one-side bolts under tension
    Liu, Yuanjian
    Sun, Lele
    Zhang, Yue
    Liu, Le
    Liu, Mei
    Wang, Peijun
    Zhang, Wenchao
    JOURNAL OF BUILDING ENGINEERING, 2022, 52
  • [7] Development of component stiffness equations for thread-fixed one-side bolt connections to an enclosed rectangular hollow section column under tension
    Wu, Fu-Wei
    Li, Yuan-Qi
    FRONTIERS OF STRUCTURAL AND CIVIL ENGINEERING, 2024, 18 (04) : 568 - 586
  • [8] Studies on T-shaped one-side bolted connection to hollow section column under bending
    Sun, Lele
    Liu, Mei
    Liu, Yuanjian
    Wang, Peijun
    Zhao, Hui
    Sun, Jian
    Shang, Yanwei
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 175
  • [9] Post fire tensile behavior of thread-fixed one-side bolt strengthened by backing plate
    You, Yang
    Zhu, Hao
    Liu, Xinyu
    Xia, Chengxin
    Liu, Mei
    Liu, Yuanjian
    Liu, Fangzhou
    ENGINEERING STRUCTURES, 2022, 252
  • [10] Tensile behaviour of T-stub to hollow section column using elliptical-head one-side bolts
    Sun, Lele
    Liu, Le
    Wu, Jiayu
    Zhang, Jin
    Cai, Xuesong
    Wang, Yuzhu
    Hou, Gangling
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 213