Single breath-hold magnetic resonance cine imaging for fast assessment of global and regional left ventricular function in clinical routine

被引:13
|
作者
Nassenstein, Kai [1 ]
Eberle, Holger [2 ]
Maderwald, Stefan [1 ,3 ]
Jensen, Christoph J. [2 ]
Heilmaier, Christina [1 ]
Schlosser, Thomas [1 ]
Bruder, Oliver [2 ]
机构
[1] Univ Hosp Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, D-45122 Essen, Germany
[2] Elisabeth Hosp, Dept Cardiol & Angiol, Essen, Germany
[3] Univ Duisburg Essen, Erwin L Hahn Inst Magnet Resonance Imaging, Essen, Germany
关键词
Cine magnetic resonace imaging; Parallel imaging; TGRAPPA; Cardiac volume; Left ventricular function; MODELING ANALYSIS; ACQUISITION; REPRODUCIBILITY; QUALITY; HEART; SENSE;
D O I
10.1007/s00330-010-1827-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate a TGRAPPA (temporal parallel acquisition technique)-accelerated, single breath-hold multi-slice cine imaging approach for the assessment of left ventricular (LV) function. One hundred eleven patients were examined at 1.5 T. Cine imaging was performed with single-slice breath-hold acquisitions in short-axis orientation using a SSFP (TR 2.63 ms, TE 1.12 ms, FA 72A degrees) sequence and a TGRAPPA SSFP (TR 2.66 ms, TE 1.11 ms, FA 72A degrees, AF 3) sequence, which covered the entire LV in multiple short-axis slices during a single breath-hold. End-diastolic (EDV), end-systolic (ESV), stroke volumes (SV), ejection fraction (EF), muscle mass (MM) and regional wall motion were assessed for both data sets. Single breath-hold imaging was feasible in 108 patients. Excellent correlations were observed for all volumetric parameters derived from both data sets (all r > 0.97). While EDV and ESV showed marginally lower values for single breath-hold imaging (EDV: -1.6 +/- 7.9 ml; ESV: -1.8 +/- 6.0 ml, p < 0.05), no differences were observed for SV, EF, MM and regional wall motion assessment. Single breath-hold imaging required significant shorter acquisition times (28 +/- 6 s vs. 335 +/- 87 s). TGRAPPA-accelerated multi-slice SSPF imaging allows for fast and accurate assessment of regional and global LV function within a single breath-hold.
引用
收藏
页码:2341 / 2347
页数:7
相关论文
共 50 条
  • [1] Single breath-hold magnetic resonance cine imaging for fast assessment of global and regional left ventricular function in clinical routine
    Kai Nassenstein
    Holger Eberle
    Stefan Maderwald
    Christoph J. Jensen
    Christina Heilmaier
    Thomas Schlosser
    Oliver Bruder
    European Radiology, 2010, 20 : 2341 - 2347
  • [2] Dual breath-hold magnetic resonance cine evaluation of global and regional cardiac function
    Bernd J. Wintersperger
    Spencer Sincleair
    Val M. Runge
    Olaf Dietrich
    Armin Huber
    Maximilian F. Reiser
    Stefan O. Schoenberg
    European Radiology, 2007, 17 : 73 - 80
  • [3] Dual breath-hold magnetic resonance cine evaluation of global and regional cardiac function
    Wintersperger, Bernd J.
    Sincleair, Spencer
    Runge, Val M.
    Dietrich, Olaf
    Huber, Armin
    Reiser, Maximilian F.
    Schoenberg, Stefan O.
    EUROPEAN RADIOLOGY, 2007, 17 (01) : 73 - 80
  • [4] CMR analysis of global and regional left ventricular function in a single breath-hold
    Holger C Eberle
    Oliver Bruder
    Christoph J Jensen
    Thomas Schlosser
    Georg V Sabin
    Christoph K Naber
    Kai Nassenstein
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [5] Fast 3D cine steady-state free precession imaging with sensitivity encoding for assessment of left ventricular function in a single breath-hold
    Mascarenhas, Neil B.
    Muthupillai, Raja
    Cheong, Benjamin
    Pereyra, Mercedes
    Flamm, Scott D.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (05) : 1235 - 1239
  • [6] Accuracy of single breath-hold cine MRI analyzed by guide-point modeling for the assessment of Left Ventricular Function
    Christina Heilmaier
    Kai Nassenstein
    Sonia Nielles-Vallespin
    Sven Zuehlsdorff
    Peter Hunold
    Joerg Barkhausen
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [7] Single breath-hold real-time MR cardiac cine for evaluation of left ventricular function
    Tomoyuki Kido
    Kouki Watanabe
    Yuta Urusibata
    Masashi Nakamura
    Michaela Schmidt
    Michael O Zenge
    Teruhito Mochizuki
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [8] Feasibility of one breath-hold cardiovascular magnetic resonance compressed sensing cine for left ventricular strain analysis
    Chen, Xiaorong
    Pan, Jiangfeng
    Hu, Yi
    Hu, Hongjie
    Pan, Yonghao
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [9] Assessment of left ventricular function with single breath-hold highly accelerated cine MRI combined with guide-point modeling
    Heilmaier, Christina
    Nassenstein, Kai
    Nielles-Vallespin, Sonia
    Zuehlsdorff, Sven
    Hunold, Peter
    Barkhausen, Joerg
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 74 (03) : 492 - 499
  • [10] Three-dimensional Magnetic Resonance Imaging Using Single Breath-hold k-t BLAST for Assessment of Global Left Ventricular Functional Parameters
    Jaroni, Jennifer
    Meier, Reinhard
    Beer, Ambros
    Herrmann, Ken
    Settles, Marcus
    Rummeny, Ernst J.
    Huber, Armin
    ACADEMIC RADIOLOGY, 2013, 20 (08) : 987 - 994