Resilient Clock Synchronization Using Power Grid Voltage

被引:5
|
作者
Rabadi, Dima [1 ]
Tan, Rui [2 ]
Yau, David K. Y. [3 ]
Viswanathan, Sreejaya [4 ]
Zheng, Hao [5 ]
Cheng, Peng [5 ]
机构
[1] ASTAR, I2R, Cyber Secur & Intelligence, 1 Fusionopolis Way,21-01 Connexis South Tower, Singapore 138632, Singapore
[2] Nanyang Technol Univ, Sch Comp Sci & Engn, N4-02C-85,50 Nanyang Ave, Singapore 639798, Singapore
[3] Singapore Univ Technol & Design, 8 Somapah Rd,Bldg 1,Level 5, Singapore 487372, Singapore
[4] Adv Digital Sci Ctr, Serangoon Ave 3,Block 135,10-15, Singapore 556114, Singapore
[5] Zhejiang Univ, State Key Lab Ind Control Technol, Zheda Rd 38, Hangzhou 310027, Peoples R China
基金
新加坡国家研究基金会;
关键词
Clock synchronization; power grid; security;
D O I
10.1145/3342048
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Many clock synchronization protocols based on message passing, e.g., the Network Time Protocol (NTP), assume symmetric network delays to estimate the one-way packet transmission time as half of the round-trip time. As a result, asymmetric network delays caused by either network congestion or malicious packet delays can cause significant synchronization errors. This article exploits sinusoidal voltage signals of an alternating current (AC) power grid to limit the impact of the asymmetric network delays on these clock synchronization protocols. Our extensive measurements show that the voltage signals at geographically distributed locations in a city are highly synchronized. Leveraging calibrated voltage phases, we develop a new clock synchronization protocol that we call Grid Time Protocol (GTP), which allows direct measurement of one-way packet transmission times between its slave and master nodes, subject to an analytic condition that can be easily verified in practice. The direct measurements render GTP resilient against asymmetric network delays under this condition. A prototype implementation of GTP maintains sub-millisecond synchronization accuracy for two nodes tens of kilometers apart in the presence of malicious packet delays. The result has been demonstrated for both Singapore and Hangzhou, China. Simulations driven by real network delay measurements between Singapore and Hangzhou under both normal and congested network conditions also show the synchronization accuracy improvement by GTP. We believe that GTP is suitable for grid-connected distributed systems that are currently served by NTP but desire higher resilience against unfavorable network dynamics and packet delay attacks.
引用
收藏
页数:26
相关论文
共 50 条
  • [1] Taming Asymmetric Network Delays for Clock Synchronization Using Power Grid Voltage
    Rabadi, Dima
    Tan, Rui
    Yau, David K. Y.
    Viswanathan, Sreejaya
    PROCEEDINGS OF THE 2017 ACM ASIA CONFERENCE ON COMPUTER AND COMMUNICATIONS SECURITY (ASIA CCS'17), 2017, : 874 - 886
  • [2] Clock Synchronization Method of Feeder Terminal Unit Using Power Frequency Voltage Signal
    Han G.
    Li Z.
    Dong X.
    Zhang W.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2019, 43 (24): : 181 - 186
  • [3] Grid voltage synchronization algorithms for grid-connected power converters
    Wen W.
    Zhang Y.
    Wang L.
    Zhao Z.
    Nie J.
    Zhang, Yingchao (zhangyingchao@tsinghua.org.cn), 1600, Tsinghua University (57): : 637 - 643
  • [4] The Construction of the Clock Synchronization System in Management Information Domain of Power Grid
    Huang, Jie
    Hou, Kai
    He, Yingli
    Jiao, Qun
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [5] Exploiting Power Grid for Accurate and Secure Clock Synchronization in Industrial IoT
    Viswanathan, Sreejaya
    Tan, Rui
    Yau, David K. Y.
    PROCEEDINGS OF 2016 IEEE REAL-TIME SYSTEMS SYMPOSIUM (RTSS), 2016, : 146 - 156
  • [6] Harmonic Voltage Synchronization Using GPS Modules for Grid-Connected Power Converters
    Araujo, Lucas Savoi
    Caldognetto, Tommaso
    Brandao, Danilo
    Mattavelli, Paolo
    IEEE OPEN JOURNAL OF POWER ELECTRONICS, 2022, 3 : 905 - 914
  • [7] Recent Advances in Precision Clock Synchronization Protocols for Power Grid Control Systems
    Jones, Terry
    Arnold, Doug
    Tuffner, Frank
    Cummings, Rodney
    Lee, Kang
    ENERGIES, 2021, 14 (17)
  • [8] VANET Clock Synchronization for Resilient DSRC Safety Applications
    Hussein, Sherif
    Krings, Axel
    Azadmanesh, Azad
    2017 RESILIENCE WEEK (RWS), 2017, : 57 - 63
  • [9] Secure and resilient clock synchronization in wireless sensor networks
    Sun, K
    Ning, P
    Wang, C
    IEEE JOURNAL ON SELECTED AREAS IN COMMUNICATIONS, 2006, 24 (02) : 395 - 408
  • [10] Resilient Clock Synchronization over Unreliable Channels in WSNs
    Kikuya, Yuhei
    Dibaji, Seyed Mehran
    Ishii, Hideaki
    2017 IEEE 56TH ANNUAL CONFERENCE ON DECISION AND CONTROL (CDC), 2017,