Miniaturized Antenna for High Data Rate Implantable Brain-Machine Interfaces

被引:11
|
作者
Abbas, Naeem [1 ]
Shah, Syed Ahson Ali [2 ]
Basir, Abdul [2 ]
Bashir, Zubair [1 ]
Akram, Adeel [1 ]
Yoo, Hyoungsuk [2 ]
机构
[1] Univ Engn & Technol Taxila, Telecommun Engn Dept, ACTSENA Res Grp, Taxila 47050, Pakistan
[2] Hanyang Univ, Dept Elect Engn, Seoul 04763, South Korea
关键词
Implantable antenna; high gain; novel shaped; specific absorption rate; ultra-wide band; PATCH ANTENNA; MIMO ANTENNA; LOOP ANTENNA; BAND; DESIGN; TELEMETRY; SYSTEM; MICS; HEAD;
D O I
10.1109/ACCESS.2022.3184778
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Technological advancements in medical care have necessitated the development of efficient and miniaturized implantable medical devices. This paper presents an ultra-wide-band implantable antenna for use in scalp-based biomedical applications covering the industrial, scientific, and medical (ISM) (2.4-2.48 GHz) band. The proposed antenna is mounted on a 0.1-mm thick liquid crystalline polymer (LCP) Roger ULTRALAM (tan delta =0.002 and epsilon(r) =2.9), serving as a dielectric material for both the superstrate and substrate layers. LCP materials are widely used in manufacturing electronic devices owing to their desirable properties, including flexibility, conformable structure, and biocompatibility. To preserve the capability of an electrically small radiator and achieve optimum performance, the proposed antenna is designed to have a volume of 9.8 mm(3) (7 mm x 7 mm x 0.2 mm). The addition of a shorting pin and open-ended slots in the radiating patch, and close-ended slots in the ground plane facilitates antenna miniaturization, impedance matching, and bandwidth expansion. Notably, the antenna exhibits a peak gain of -20.71 dBi and impedance-matched bandwidth of 1038.7 MHz in the ISM band. Moreover, the antenna is safe to use according to the IEEE C905.1-2005 safety guidelines based on low specific absorption rates. To evaluate the performance of the implantable antenna, finite-element simulation was performed in homogeneous and heterogeneous environments. For validation, measurements were performed in a minced pork-filled container. The simulation results are consistent with the measurements. In addition, a link budget analysis is performed to confirm the robustness and reliability of the wireless telemetric link and determine the range of the implantable antenna.
引用
收藏
页码:66018 / 66027
页数:10
相关论文
共 50 条
  • [1] Design and Measurement of a Minuscule-Sized Implantable Antenna for Brain-Machine Interfaces
    Abbas, Naeem
    Ullah, Sana
    Bashir, Zubair
    Basir, Abdul
    Yoo, Hyoungsuk
    IEEE ACCESS, 2023, 11 : 77980 - 77989
  • [2] A Glucose Fuel Cell for Implantable Brain-Machine Interfaces
    Rapoport, Benjamin I.
    Kedzierski, Jakub T.
    Sarpeshkar, Rahul
    PLOS ONE, 2012, 7 (06):
  • [3] Advancing Brain-Machine Interfaces: High Data Rate Battery-Free Implants
    Hasanvand, Aminolah
    Khaleghi, Ali
    Beguet, Cyril
    Wanda, Paul
    Balasingham, Ilangko
    2023 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE, IMBIOC, 2023, : 70 - 72
  • [4] Design of an Implantable Intracortical Microelectrode System for Brain-Machine Interfaces
    Patrick, Erin
    Sankar, Viswanath
    Rowe, William
    Sanchez, Justin C.
    Nishida, Toshikazu
    2009 4TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING, 2009, : 372 - +
  • [5] Energy-Efficient High-Voltage Compliant Implantable Brain-Machine Interfaces
    Hasanuzzaman, Md.
    Raut, Rabin
    Sawan, Mohamad
    2013 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2013, : 81 - 84
  • [6] Brain-machine interfaces
    Pissaloux, Edwige
    BIOFUTUR, 2011, (322) : 50 - 53
  • [7] Brain-machine interfaces
    Contreras-Vidal, J. L.
    Prasad, S.
    Kilicarslan, A.
    Bhagat, N.
    Bhattacharyya, R.
    Uhlenbrock, R. M.
    Payton, D. W.
    Panova, J. S.
    Marcus, J. D.
    Panova, T. B.
    Leuthardt, E. C.
    Love, L. J.
    Coker, R.
    Moran, D. W.
    Nuyujukian, P.
    Kao, J. C.
    Shenoy, K., V
    Schiff, N. D.
    Kao, J. C.
    Nuyujukian, P.
    Churchland, M. M.
    Cunningham, J. P.
    Shenoy, K., V
    NATURE BIOTECHNOLOGY, 2019, 37 (09) : 1001 - 1001
  • [8] Are brain-machine interfaces the real experience machine? Exploring the libertarian risks of brain-machine interfaces
    Mateus, Jorge
    AI & SOCIETY, 2025,
  • [9] Miniaturized UWB Implantable Antenna for Brain-Machine-Interface
    Yazdandoost, Kamya Yekeh
    Miura, Ryu
    2015 9th European Conference on Antennas and Propagation (EuCAP), 2015,
  • [10] Manufacturing, Assembling and Packaging of Miniaturized Implants for Neural Prostheses and Brain-Machine Interfaces
    Stieglitz, Thomas
    SMART SENSORS, ACTUATORS, AND MEMS IV, 2009, 7362