Behaviour of Galvanized High Strength Grade 10.9 Bolts Under Fire Conditions

被引:0
|
作者
Gonzalez, F. [1 ]
Lange, J. [1 ]
机构
[1] Tech Univ Darmstadt, Inst Steel Struct & Mat Mech, D-64287 Darmstadt, Germany
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the last decades structural fire design has changed essentially. In the past the structural integrity of single elements was mostly proven by load tables which were based on fire tests. The introduction of the "hot" Eurocodes (Parts 1-2) offers the possibility to assess the resistance even of complex structural systems under fire conditions. For this purpose a calculation can be made according to the Eurocodes taking into account the relevant material behaviour which is mainly known for structural steel and concrete elements. The material behaviour is defined in the ECs by stress strain curves, depending on the temperature. Even for connections design rules are given in the Eurocodes. The resistance of bolts and welding seams under fire conditions can easily be calculated using global reduction factors which depend on the element temperature. The global reduction factors for bolts are currently valid for all grades. The experience shows that either differing alloying materials or varying treatment methods can lead to a relevant change in the ultimate strength. These two points have an important influence on the production process of galvanized high strength grade 10.9 bolts. Due to this tension tests on specimens and galvanized bolt assemblies have been carried out in order to evaluate the behaviour under fire conditions. The results will give on one hand the possibility to verify the reduction factors for grade 10.9 bolts given in the Eurocode and on the other hand a more precise understanding of high strength bolt behaviour under fire conditions. The paper will describe the state of the art, the elaborated tests in more depth and present results.
引用
收藏
页码:908 / 915
页数:8
相关论文
共 50 条
  • [1] Behaviour of High Strength Grade 10.9 Bolts under Fire Conditions
    Gonzalez, Fernando
    Lange, Joerg
    STEEL CONCRETE COMPOSITE AND HYBRID STRUCTURES, 2009, : 517 - 522
  • [2] Behavior of High-Strength Grade 10.9 Bolts under Fire Conditions
    Lange, Joerg
    Gonzalez, Fernando
    STRUCTURAL ENGINEERING INTERNATIONAL, 2012, 22 (04) : 470 - 475
  • [3] Creep behavior of Grade 10.9 high-strength bolts under and after fire
    Lu, Yaoliang
    Jiang, Jian
    Cai, Wenyu
    Chen, Wei
    Ye, Jihong
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 351
  • [4] Behaviour and design of Grade 10.9 high-strength bolts under combined actions
    Li, Dongxu
    Uya, Brian
    Wang, Jia
    Song, Yuchen
    STEEL AND COMPOSITE STRUCTURES, 2020, 35 (03): : 327 - 341
  • [5] Tensile and shear strength of 10.9 grade bolts in heating and cooling fire
    Mushahary, Suman Kumar
    Singh, Konjengbam Darunkumar
    Jayachandran, S. Arul
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 197
  • [6] Fracture behavior of Grade 10.9 high-strength bolts and T-stub connections in fire
    Lu, Yaoliang
    Jiang, Jian
    Chen, Qiao
    Cai, Wenyu
    Chen, Wei
    Ye, Jihong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 199
  • [7] Behaviour of Grade 8.8 bolts under natural fire conditions-Tests and model
    Hanus, F.
    Zilli, G.
    Franssen, J. -M.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (08) : 1292 - 1298
  • [8] Behaviour of High Strength Steel under Fire Conditions
    Winful, Dorothy A.
    Cashell, Katherine A.
    Barnes, Adriene M.
    Pargeter, Richard J.
    STRUCTURES IN FIRE, 2016, : 624 - 631
  • [9] High strength bolts under the influence of fire
    González, Fernando
    Lange, Jörg
    VDI Berichte, 2009, (2062): : 31 - 43
  • [10] THE BEHAVIOR OF HIGH-STRENGTH GRADE 8.8 BOLTS IN FIRE
    KIRBY, BR
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1995, 33 (1-2) : 3 - 38