Cuff-Less Blood Pressure Prediction from ECG and PPG Signals Using Fourier Transformation and Amplitude Randomization Preprocessing for Context Aggregation Network Training

被引:8
|
作者
Treebupachatsakul, Treesukon [1 ]
Boosamalee, Apivitch [1 ]
Shinnakerdchoke, Siratchakrit [1 ]
Pechprasarn, Suejit [2 ]
Thongpance, Nuntachai [2 ]
机构
[1] King Mongkuts Inst Technol Ladkrabang, Sch Engn, Dept Biomed Engn, Bangkok 10520, Thailand
[2] Rangsit Univ, Coll Biomed Engn, Pathum Thani 12000, Thailand
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 03期
关键词
electrocardiogram; photoplethysmography; blood pressure measurement; context aggregation network; cuff-less blood pressure measurement; TIME;
D O I
10.3390/bios12030159
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This research proposes an algorithm to preprocess photoplethysmography (PPG) and electrocardiogram (ECG) signals and apply the processed signals to the context aggregation network-based deep learning to achieve higher accuracy of continuous systolic and diastolic blood pressure monitoring than other reported algorithms. The preprocessing method consists of the following steps: (1) acquiring the PPG and ECG signals for a two second window at a sampling rate of 125 Hz; (2) separating the signals into an array of 250 data points corresponding to a 2 s data window; (3) randomizing the amplitude of the PPG and ECG signals by multiplying the 2 s frames by a random amplitude constant to ensure that the neural network can only learn from the frequency information accommodating the signal fluctuation due to instrument attachment and installation; (4) Fourier transforming the windowed PPG and ECG signals obtaining both amplitude and phase data; (5) normalizing both the amplitude and the phase of PPG and ECG signals using z-score normalization; and (6) training the neural network using four input channels (the amplitude and the phase of PPG and the amplitude and the phase of ECG), and arterial blood pressure signal in time-domain as the label for supervised learning. As a result, the network can achieve a high continuous blood pressure monitoring accuracy, with the systolic blood pressure root mean square error of 7 mmHg and the diastolic root mean square error of 6 mmHg. These values are within the error range reported in the literature. Note that other methods rely only on mathematical models for the systolic and diastolic values, whereas the proposed method can predict the continuous signal without degrading the measurement performance and relying on a mathematical model.
引用
收藏
页数:20
相关论文
共 10 条
  • [1] Cuff-less Blood Pressure measurement from Wireless ECG and PPG signals
    Dave, Tejal
    Pandya, Utpal
    Joshi, Maulin
    2021 IEEE INTERNATIONAL SYMPOSIUM ON SMART ELECTRONIC SYSTEMS (ISES 2021), 2021, : 33 - 37
  • [2] Novel Deep Convolutional Neural Network for Cuff-less Blood Pressure Measurement Using ECG and PPG Signals
    Yan, Cong
    Li, Zhenqi
    Zhao, Wei
    Hu, Jing
    Jia, Dongya
    Wang, Hongmei
    You, Tianyuan
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 1917 - 1920
  • [3] Cuff-Less Continuous Blood Pressure Estimation from Electrocardiogram(ECG) and Photoplethysmography (PPG) Signals with Artificial Neural Network
    Senturk, Umit
    Yucedag, Ibrahim
    Polat, Kemal
    2018 26TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2018,
  • [4] Cuff-less Blood Pressure Measurement Using Supplementary ECG and PPG Features Extracted Through Wavelet Transformation
    Singla, Muskan
    Sistla, Prasad
    Azeemuddin, Syed
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 4628 - 4631
  • [5] Boosting Algorithms based Cuff-less Blood Pressure Estimation from Clinically Relevant ECG and PPG Morphological Features
    Ghosh, Aayushman
    Sarkar, Sayan
    Liu, Haipeng
    Mandal, Subhamoy
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [6] Higher Order Derivative-Based Integrated Model for Cuff-Less Blood Pressure Estimation and Stratification Using PPG Signals
    Gupta, Shresth
    Singh, Anurag
    Sharma, Abhishek
    Tripathy, Rajesh Kumar
    IEEE SENSORS JOURNAL, 2022, 22 (22) : 22030 - 22039
  • [7] Continuous Blood Pressure Prediction from Pulse Transit Time Using ECG and PPG Signals
    Ghosh, Shrimanti
    Banerjee, Ankur
    Ray, Nilanjan
    Wood, Peter W.
    Boulanger, Pierre
    Padwal, Raj
    2016 IEEE HEALTHCARE INNOVATION POINT-OF-CARE TECHNOLOGIES CONFERENCE (HI-POCT), 2016, : 188 - 191
  • [8] NABNet: A Nested Attention-guided BiConvLSTM network for a robust prediction of Blood Pressure components from reconstructed Arterial Blood Pressure waveforms using PPG and ECG signals
    Mahmud, Sakib
    Ibtehaz, Nabil
    Khandakar, Amith
    Rahman, M. Sohel
    Gonzales, Antonio JR.
    Rahman, Tawsifur
    Hossain, Md Shafayet
    Hossain, Md. Sakib Abrar
    Faisal, Md. Ahasan Atick
    Abir, Farhan Fuad
    Musharavati, Farayi
    Chowdhury, Muhammad E. H.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 79
  • [9] Schrödinger spectrum based continuous cuff-less blood pressure estimation using clinically relevant features from PPG signal and its second derivative
    Sarkar, Sayan
    Ghosh, Aayushman
    COMPUTERS IN BIOLOGY AND MEDICINE, 2023, 166
  • [10] Continuous blood pressure prediction system using Conv-LSTM network on hybrid latent features of photoplethysmogram (PPG) and electrocardiogram (ECG) signals
    Kamanditya, Bharindra
    Fuadah, Yunendah Nur
    Mahardika T., Nurul Qashri
    Lim, Ki Moo
    SCIENTIFIC REPORTS, 2024, 14 (01):