Comparative Investigations on In Vitro Serum Stability of Polymeric Micelle Formulations

被引:64
|
作者
Miller, Tobias [1 ,2 ]
Rachel, Reinhard [3 ]
Besheer, Ahmed [2 ,4 ]
Uezguen, Senta [2 ]
Weigandt, Markus [2 ]
Goepferich, Achim [1 ]
机构
[1] Univ Regensburg, Dept Pharmaceut Technol, D-93040 Regensburg, Germany
[2] Merck KGaA, Exploratory Pharmaceut Dev, D-64293 Darmstadt, Germany
[3] Univ Regensburg, Ctr Electron Microscopy, Inst Anat, D-93040 Regensburg, Germany
[4] Univ Munich, Dept Pharm Pharmaceut Technol & Biopharmaceut, D-81377 Munich, Germany
关键词
field flow fractionation; foerster resonance energy transfer; polymeric micelles; serum stability; transmission electron microscopy; AMPHIPHILIC DIBLOCK COPOLYMERS; KINETICALLY FROZEN COLLOIDS; DRUG-DELIVERY; NONIONIC SURFACTANT; BLOCK-COPOLYMERS; VIVO STABILITY; NANOPARTICLES; SYSTEMS; PEG; MACROSURFACTANTS;
D O I
10.1007/s11095-011-0555-x
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Stability of polymeric micelles upon injection is essential for a drug delivery system but is not fully understood. We optimized an analytical test allowing quantification of micellar stability in biofluids and applied it to a variety of block copolymer micelles with different hydrophobic block architechtures. Polymeric micelles were prepared from four different polymers and investigated via encapsulation of two fluorescent dyes. Samples were incubated in human serum; changes in Foerster Resonance Energy Transfer (FRET) were recorded as a function of time. This fluorescence-based approach was supported semi-quantitatively by results from Asymmetrical Flow Field-Flow-Fractionation (AF4). After incubation experiments, micellar stability was determined by calculation of two stability-indicating parameters: residual micellar fractions (RMFs) and in vitro serum half-lives. Both parameters showed that PEG-PVPy micelles rapidly destabilized after 3 h (RMF < 45%), whereas PEG-PLA, PEG-PLGA and PEG-PCL micelles were far more stable (RMFs 65 to 98%). This FRET-based assay is a valuable tool in evaluating and screening serum stability of polymeric micelles and revealed low serum stability of PEG-PVPy micelles compared to polyester-based micelles.
引用
收藏
页码:448 / 459
页数:12
相关论文
共 50 条
  • [1] Comparative Investigations on In Vitro Serum Stability of Polymeric Micelle Formulations
    Tobias Miller
    Reinhard Rachel
    Ahmed Besheer
    Senta Uezguen
    Markus Weigandt
    Achim Goepferich
    Pharmaceutical Research, 2012, 29 : 448 - 459
  • [2] Polymeric micelle stability
    Owen, Shawn C.
    Chan, Dianna P. Y.
    Shoichet, Molly S.
    NANO TODAY, 2012, 7 (01) : 53 - 65
  • [3] Mucosal Penetrative Polymeric Micelle Formulations for Insulin Delivery to the Respiratory Tract
    Kang, Ji-Hyun
    Jeong, Jin-Hyuk
    Kwon, Yong-Bin
    Kim, Young-Jin
    Shin, Dae Hwan
    Park, Yun-Sang
    Hyun, Soonsil
    Kim, Dong-Wook
    Park, Chun-Woong
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2024, 19 : 9195 - 9211
  • [4] Investigations on the lyophilisation of MPEG-hexPLA micelle based pharmaceutical formulations
    Di Tommaso, Claudia
    Como, Caterina
    Gurny, Robert
    Moeller, Michael
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2010, 40 (01) : 38 - 47
  • [5] Cheminformatics-driven discovery of polymeric micelle formulations of poorly soluble drugs
    Muratov, Eugene
    Alves, Vinicius
    Hwang, Duhyeong
    Sokolsky, Marina
    Lebed, Elena
    Vinod, Natasha
    Andrade, Carolina
    Kabanov, Alexander
    Tropsha, Alexander
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [6] Cheminformatics-driven discovery of polymeric micelle formulations for poorly soluble drugs
    Alves, Vinicius M.
    Hwang, Duhyeong
    Muratov, Eugene
    Sokolsky-Papkov, Marina
    Varlamova, Ekaterina
    Vinod, Natasha
    Lim, Chaemin
    Andrade, Carolina H.
    Tropsha, Alexander
    Kabanov, Alexander
    SCIENCE ADVANCES, 2019, 5 (06)
  • [7] Preparation, characterization, cytotoxicity and biodistribution of docetaxel-loaded polymeric micelle formulations
    Le Garrec, D
    Gori, S
    Karkan, D
    Luo, L
    Lessard, DG
    Smith, D
    Ranger, M
    Yessine, MA
    Leroux, JC
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2005, 15 (02) : 115 - 120
  • [8] A novel cabazitaxel-loaded polymeric micelle system with superior in vitro stability and long blood circulation time
    Han, Xiaoxiong
    Chen, Dan
    Sun, Jing
    Zhou, Jinsong
    Li, Duan
    Gong, Feirong
    Shen, Yaling
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2016, 27 (07) : 626 - 642
  • [9] Development of Retinol-loaded Polymeric Micelle: Stability of Retinol
    Yang, Hee Seon
    An, Joo Young
    Kim, Chae Jin
    Koo, Tea-Sung
    Lee, Eun Hee
    Yuk, Soon-Hong
    Lee, Jae-Hwi
    Shin, Byung Cheol
    Cho, Seon-Hang
    POLYMER-KOREA, 2021, 45 (01) : 79 - 88
  • [10] Polyether-polyester diblock copolymers for the preparation of paclitaxel loaded polymeric micelle formulations
    Liggins, RT
    Burt, HM
    ADVANCED DRUG DELIVERY REVIEWS, 2002, 54 (02) : 191 - 202