Electrochemical behavior of Pb (II) on a heparin modified chitosan/graphene nanocomposite film coated glassy carbon electrode and its sensitive detection

被引:21
|
作者
Priya, T. [1 ]
Dhanalakshmi, N. [1 ]
Thinakaran, N. [1 ]
机构
[1] Alagappa Govt Arts Coll, PG & Res Dept Chem, Environm Res Lab, Karaikkudi 630003, Tamil Nadu, India
关键词
Heparin; Chitosan; Reduced graphene oxide; Metal ion; Simultaneous detection; ANODIC-STRIPPING VOLTAMMETRY; LEAD IONS; GRAPHENE; PB(II); REMOVAL; CD(II);
D O I
10.1016/j.ijbiomac.2017.06.082
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this study, we developed a novel composite material containing biological macromolecules like heparin and chitosan coated on reduced graphene oxide (rGO) for the modification of glassy carbon electrode (hep/CS-rGO/GC). It can be applied for the sensitive electrochemical detection of Pb2+ by square wave anodic stripping voltammetry (SWASV). The physicochemical analysis such as XRD, FTIR, FESEM and Raman spectroscopy techniques revealed that an effective functionalizati on occurred at the rGO surface. The consequence of deposition and stripping of metal ions by various electrochemical parameters such as supporting electrolytes, pH value, deposition potential, and deposition time were carefully studied and optimized. Under the optimized conditions, the linear calibration curve was calculated to be from 1.125 to 8.25 mu g L-1 for Pb2(+) with the correlation coefficient (R-2) 0.9988. The detection limit and sensitivity achieved for the modified electrode were 0.03 1.1gL(-1) and 1.3411,A/nM respectively. Furthermore, the electrochemical investigation indicates that the hep/CS-rGO composite electrode exhibits high selectivity, strong adherence to the electrode surface, good stability and reproducibility towards the detection of Pb2*. Finally, hep/CS-rGO/GC electrode was assessed by the quantity of Pb2* present in the practical samples, and the determined results were consistent with that of AAS. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:672 / 680
页数:9
相关论文
共 50 条
  • [1] Electrochemical behavior of luteolin on a chitosan-graphene modified glassy carbon electrode and its sensitive detection
    Li, Guangjiu
    Liu, Lihua
    Cheng, Yong
    Gong, Shixing
    Wang, Xiuli
    Geng, Xiujuan
    Sun, Wei
    ANALYTICAL METHODS, 2014, 6 (23) : 9354 - 9360
  • [2] The graphene/polypyrrole/chitosan-modified glassy carbon electrode for electrochemical nitrite detection
    Qi Xiao
    Mengmeng Feng
    Yi Liu
    Shuangyan Lu
    Yingzi He
    Shan Huang
    Ionics, 2018, 24 : 845 - 859
  • [3] The graphene/polypyrrole/chitosan-modified glassy carbon electrode for electrochemical nitrite detection
    Xiao, Qi
    Feng, Mengmeng
    Liu, Yi
    Lu, Shuangyan
    He, Yingzi
    Huang, Shan
    IONICS, 2018, 24 (03) : 845 - 859
  • [4] Electrochemical Determination of Pentachlorophenol Using a Glassy Carbon Electrode Modified with a Film of CuS Nanocomposite-Chitosan
    Zou, Jing
    Ma, Jinai
    Zhang, Yuanxiao
    Li, Lu
    Jiang, Jizhou
    Chen, Jinfang
    ANALYTICAL LETTERS, 2013, 46 (07) : 1108 - 1116
  • [5] Nonenzymatic electrochemical detection of rutin on Pt nanoparticles/graphene nanocomposite modified glassy carbon electrode
    Li, Shumin
    Yang, Beibei
    Wang, Jin
    Bin, Duan
    Wang, Caiqin
    Zhang, Ke
    Du, Yukou
    ANALYTICAL METHODS, 2016, 8 (27) : 5435 - 5440
  • [6] Sensitive Electrochemical Detection of Dopamine With a Nitrogen-doped Graphene Modified Glassy Carbon Electrode
    Wang, Wencheng
    Gong, Shixing
    Sun, Wei
    Li, Guangjiu
    Lu, Yaping
    Yu, Jianhua
    Dong, Lifeng
    CROATICA CHEMICA ACTA, 2016, 89 (03) : 323 - 330
  • [7] ZnO@graphene nanocomposite modified electrode for sensitive and simultaneous detection of Cd (II) and Pb (II)
    Yukird, Jutiporn
    Kongsittikul, Pongsakorn
    Qin, Jiaqian
    Chailapakul, Orawon
    Rodthongkum, Nadnudda
    SYNTHETIC METALS, 2018, 245 : 251 - 259
  • [8] Electrochemical behavior of luteolin and its detection based on macroporous carbon modified glassy carbon electrode
    Zeng, Lijun
    Zhang, Yufan
    Wang, Huan
    Guo, Liping
    ANALYTICAL METHODS, 2013, 5 (13) : 3365 - 3370
  • [9] Electrochemical detection of ciprofloxacin based on graphene modified glassy carbon electrode
    Xie, A. -J.
    Chen, Y.
    Luo, S. -P.
    Tao, Y. -W.
    Jin, Y. -S.
    Li, W. -W.
    MATERIALS TECHNOLOGY, 2015, 30 (06) : 362 - 367
  • [10] Electrochemical Behavior and Sensitive Detection of Luteolin by Graphene-SnO2 Nanocomposite Modified Electrode
    Li, Xiaobao
    Niu, Xueliang
    Chen, Wei
    Dong, Lifeng
    Niu, Yanyan
    Shao, Taiming
    Lai, Wenting
    Sun, Wei
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (10): : 9774 - 9783