A Novel Starting Method of the SPM-type BLDC Motors without Position Sensor for Reciprocating Compressor

被引:0
|
作者
Kim, Dae-Kyong [1 ,4 ]
Lee, Kwang-Woon [2 ]
Kim, Byung-Taek [3 ]
Kwon, Byung-il [4 ]
机构
[1] Korea Elect Technol Inst, Kwangju 500706, South Korea
[2] Samsung Elect, Home Appliances Lab, Suwon 443742, South Korea
[3] Kun Shan Univ, Kunsan 573701, South Korea
[4] Hanyang Univ, Energy Convers Syst Lab, Ansan 425791, South Korea
来源
CONFERENCE RECORD OF THE 2006 IEEE INDUSTRY APPLICATIONS CONFERENCE, FORTY-FIRST IAS ANNUAL MEETING, VOL 1-5 | 2006年
关键词
brushless DC motor; reciprocating compressor; sensorless control; starting method;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper proposes a new starting method of the SPM-type BLDC motors without position sensor to prevent the demagnetization phenomena and vibration of reciprocating compressor taken ferrite-type permanent magnet. The experimental test of irreversible demagnetization is performed to obtain the irreversible demagnetization level of the BLDC reciprocating compressor when peak current is applied. The proposed method is implemented on the commercial refrigerator using a BLDC reciprocating compressor. The experimental results show that the proposed method considerably reduces not only instantaneous peak currents but also vibration of reciprocating compressor. The proposed method makes possible that home appliances using BLDC motor, such as refrigerator and air-conditioner, to obtain the good performance
引用
收藏
页码:861 / 865
页数:5
相关论文
共 16 条
  • [1] A novel starting method of the surface permanent-magnet BLDC motors without position sensor for reciprocating compressor
    Lee, Kwang-Woon
    Kim, Dae-Kyong
    Kim, Byung-Taek
    Kwon, Byung-Il
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2008, 44 (01) : 85 - 92
  • [2] Novel Position Sensorless Starting Method of BLDC Motor for Reciprocating Compressor
    Kim, Dae-kyong
    Shin, Duck-shik
    Lee, Sang-Taek
    Kim, Hee-Jun
    Kwon, Byung-Il
    Kim, Byung-Taek
    Lee, Kwang-Woon
    INTELEC 09 - 31ST INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE, 2009, : 941 - 945
  • [3] A new starting method of BLDC motors without position sensor
    Lee, WJ
    Sul, SK
    CONFERENCE RECORD OF THE 2004 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4: COVERING THEORY TO PRACTICE, 2004, : 2397 - 2402
  • [4] A new starting method of BLDC motors without position sensor
    Lee, Wook-Jin
    Sul, Seung-Ki
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2006, 42 (06) : 1532 - 1538
  • [5] A novel starting method for BLDC motors without the position sensors
    Asaei, Behzad
    Rostami, Alireza
    ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (02) : 337 - 343
  • [6] Comparison of Starting Method for Position Sensorless BLDC Motor Driven Reciprocating Compressor
    Kim, Dae-kyong
    Rhyu, Se-hyun
    Lee, Kwang-woon
    Kim, Byung-taek
    Chung, Dong-hwa
    Kwon, Byung-il
    2008 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, VOLS 1-5, 2008, : 707 - +
  • [7] A novel method for estimating the initial rotor position of PM motors without the position sensor
    Rostami, Alireza
    Asaei, Behzad
    ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (08) : 1879 - 1883
  • [8] Comparison of the Fault Characteristics of IPM-Type and SPM-Type BLDC Motors Under Inter-Turn Fault Conditions Using Winding Function Theory
    Kim, Kyung-Tae
    Park, Jun-Kyu
    Hur, Jin
    Kim, Byeong-Woo
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2014, 50 (02) : 986 - 994
  • [9] Comparison of the Fault Characteristics of IPM-type and SPM-type BLDC Motors under Inter-Turn Faults Conditions Using Winding Function Theory
    Kim, Kyung-tae
    Park, Jun-kyu
    Kim, Byeong-woo
    Hur, Jin
    2012 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2012, : 1262 - 1269
  • [10] Novel PWM Method with Low Ripple Current for Position Control Applications of BLDC Motors
    Kim, Hag-Wone
    Shin, Hee-Keun
    Mok, Hyung-Soo
    Lee, Yong-Kyun
    Cho, Kwan-Yuhl